Series Six
IC600BF830 — Advanced I/O receiver module

IC600BF830 receives the Series Six I/O link at the rack interface and supports the associated diagnostic functions. Check rack position, link termination and the fitted revision before restoring a remote I/O arrangement.

General ElectricSeries SixLeftmost I/O-rack slotLeftmost I/O-rack position; two 37-pin connections
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
IC600BF830 product profile
ManufacturerGeneral Electric
Exact modelIC600BF830
Product typeAdvanced I/O receiver module
Product familySeries Six
Primary roleReceives the rack I/O link
Interface contextLeftmost I/O-rack position; two 37-pin connections
  • Brand:

    General Electric
  • Item NO.:

    IC600BF830
IC600BF830 configuration inquiry

Get a precise quote for IC600BF830

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

Advanced I/O receiver module configuration

IC600BF830 receives the Series Six I/O link at the rack interface and supports the associated diagnostic functions. Check rack position, link termination and the fitted revision before restoring a remote I/O arrangement.

System roleIC600BF830 receives the Series Six I/O link at the rack interface and supports the associated diagnostic functions. Check rack position, link termination and the fitted revision before restoring a remote I/O arrangement.
Electrical integrationInclude the covered receiver revision in the rack 5 VDC power budget.
Configuration reviewSet link termination and diagnostic configuration for the actual rack position and receiver revision.
CommissioningVerify the I/O-link status and controlled responses of the rack’s assigned field circuits.

Engineering selection points

  • Rack location: Leftmost I/O-rack slot.
  • Front connections: Two 37-pin connectors.
  • Logic supply: 5 VDC.
  • Typical logic current: 680 mA for the covered manual revision.
Official product data

IC600BF830 key specifications

Rack locationLeftmost I/O-rack slot
Front connectionsTwo 37-pin connectors
Logic supply5 VDC
Typical logic current680 mA for the covered manual revision
Maximum logic current1.2 A for the covered manual revision
External rack ambient0–60 °C
Humidity5–95%, noncondensing

Technical reference: GEK-90771, Advanced I/O Receiver instruction sheet in the approved GE Series Six archive.

Pre-order check 01

Installation environment

Check the mounting, connection and operating conditions for this exact configuration before installation.

  • Isolate the affected rack and record its position in the I/O chain.
  • Retain the link-cable identification and inspect both 37-pin connections.
  • Compare the installed termination and diagnostic settings with the rack arrangement.
  • Check rack power, link status and assigned field signals before process release.
Record the installed arrangement and the final controlled checks in the commissioning file.
Pre-order check 02

Compatibility confirmation

Match the complete item to its field interface, mechanical arrangement and configured system.

Complete item
Retain IC600BF830 and record the supplied board revision.
Installed assembly
Leftmost I/O-rack position; two 37-pin connections.
Electrical conditions
Include the covered receiver revision in the rack 5 VDC power budget.
Configuration
Set link termination and diagnostic configuration for the actual rack position and receiver revision.
Acceptance
Verify the I/O-link status and controlled responses of the rack’s assigned field circuits.
Match the complete supplied identity, board revision and installed circuit requirements before operational release.
Recommended model families

More General Electric models

General Electric selections 01General Electric DS200SHVIG1AGeneral Electric DS200PTCTG1AGeneral Electric DS200PLIBG1A

Match the complete ordering code and installed-system requirements before selection.

General Electric selections 02General Electric DS200PANAH1AGeneral Electric DS200FHVAG1AGeneral Electric DS200FCGDH1A

Match the complete ordering code and installed-system requirements before selection.

General Electric selections 03General Electric DS200EXPSG1ABBGeneral Electric DS200EXDEG1AGeneral Electric DS200DMCBG2AKG

Match the complete ordering code and installed-system requirements before selection.

General Electric selections 04General Electric DS200DMCBG2AGeneral Electric DS200ACNAG1AGeneral Electric DS200AAHAH1A

Match the complete ordering code and installed-system requirements before selection.

Additional published brands

Additional Advantage Models

Additional selections 01Siemens 6ES7155-5BA00-0AB0Siemens 6GK7177-1MA20-0AA0Siemens 6ES7143-5BF00-0BA0

Match the complete ordering code and installed-system requirements before selection.

Additional selections 02Siemens 6ES7144-5KD00-0BA0Siemens 6ES7144-4PF00-0AB0Siemens 6ES7144-4JF00-0AB0

Match the complete ordering code and installed-system requirements before selection.

Additional selections 03Siemens 6ES7144-4FF01-0AB0Siemens 6ES7144-1JB31-0XB0Siemens 6ES7144-1GB31-0XB0

Match the complete ordering code and installed-system requirements before selection.

Additional selections 04Siemens 6GK5308-2FM10-2AA3Siemens 6ES7143-5AH00-0BA0Siemens 6ES7143-4BF50-0AA0

Match the complete ordering code and installed-system requirements before selection.

Additional selections 05Siemens 6ES7142-6BH00-0AB0Siemens 6GK1143-0TA02Siemens 6GK1143-0AA01

Match the complete ordering code and installed-system requirements before selection.

Additional selections 06Siemens 6ES5951-7LB21Siemens 6ES5948-3UA23Siemens 6ES5948-3UA13

Match the complete ordering code and installed-system requirements before selection.

Additional selections 07Siemens 6ES5945-7UA23Siemens 6ES5941-7UA12Siemens 6ES5921-3WB12

Match the complete ordering code and installed-system requirements before selection.

Additional selections 08Siemens 6ES5541-8AA11Siemens 6ES5470-4UC13Siemens 6ES5465-4UA13

Match the complete ordering code and installed-system requirements before selection.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

IC600BF830 Order Guide

Match the complete configuration to the installed requirement before finalizing the order.
1Confirm the exact itemIC600BF830 — Advanced I/O receiver module.
2Check the field interfaceLeftmost I/O-rack position; two 37-pin connections.
3Review the installationIsolate the affected rack and record its position in the I/O chain.
4Match the configured systemRetain IC600BF830 and record the supplied board revision.
5Agree the supplied scopeConfirm the requested quantity, condition, package contents and destination with the quotation.
6Plan a controlled acceptanceMatch the complete supplied identity, board revision and installed circuit requirements before operational release.

Middle East Demand & Specialist Models

Selected published product references for regional projects and installed-system maintenance.

Published references for regional project selection.
Confirm the exact part number before ordering.
Siemens6ES7151-8AB00-0AB0

IM151-8 PN/DP CPU module. Match the complete configuration and supplied scope.

Published model reference
Siemens6ES7152-1BA00-0AB0

IM152-1PN interface module. Match the complete configuration and supplied scope.

Published model reference
Siemens6ES7153-2BB00-0XB0

IM153-2 FO interface module. Match the complete configuration and supplied scope.

Specialist brand
Siemens6ES7154-2AA01-0AB0

IM154-2 DP HF interface module. Match the complete configuration and supplied scope.

Specialist brand
Siemens6ES7155-5BA00-0AB0

IM155-5 DP ST interface module. Match the complete configuration and supplied scope.

Specialist brand
Siemens6GK7177-1MA20-0AA0

CSM12/24 unmanaged Ethernet switch. Match the complete configuration and supplied scope.

Specialist brand
Nordwel customer support

Company Services & FAQ

Configuration and order support for General Electric IC600BF830.

Company services

Model & configuration checkReview the complete item and leftmost i/o-rack position; two 37-pin connections requirements before quotation.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

IC600BF830 FAQ

Where is IC600BF830 installed in the I/O rack?It occupies the leftmost I/O-rack slot in the covered arrangement. Confirm that position from the installed rack layout before reconnecting the link cables.
How many front link connections are provided?The receiver has two 37-pin front connections. Identify the cable paths before removal so the restored connection follows the correct rack-chain arrangement.
What logic-supply capacity should be allowed for the receiver?The covered instruction sheet lists a 5 VDC supply, 680 mA typical current and 1.2 A maximum current. Check that the actual receiver revision and rack supply budget agree with those figures.
Does a receiver replacement always keep the same termination setting?The required termination depends on the receiver’s position in the installed link and its configuration. Record the existing settings and compare them with the intended rack arrangement rather than relying on the replacement’s arrival setting.
Which temperature is relevant to the 0–60 °C range?The stated range refers to the external rack ambient. A room reading alone does not establish the temperature around a loaded rack inside a cabinet.
Can the rack be accepted after only its power indicator is checked?Power is only one part of acceptance. Check the I/O-link diagnostics and test the required field-signal behavior for the rack before authorizing operation.
Why does the receiver revision belong in the spare record?Revision-dependent termination and diagnostic arrangements can affect integration. Preserve the fitted revision and configuration record together with the requested base designation.
What should be inspected at the link connectors?Inspect pins, mating condition, cable retention and the identified cable routes with the rack isolated. A damaged or incorrectly restored link connection can prevent normal rack communication.
Is condensation allowed within the stated humidity range?No. The humidity specification is 5–95% noncondensing. Evaluate cabinet conditions that could produce condensation during temperature changes or shutdown periods.
How should an I/O-link fault be investigated after installation?Compare rack power, cable paths, connector condition and the required termination/diagnostic settings. Relate the link indications to the rack position before attributing the problem to a field device.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
General Electric Series Six

Applications & Why Choose Nordwel

Engineering contexts for IC600BF830 and the available order-coordination support.

Application areas

01Remote I/O link receptionConnect the installed Series Six rack to its approved I/O-link arrangement.
02Rack-chain maintenancePreserve link order and termination configuration when replacing the receiver.
03Power-budget assessmentInclude the actual receiver revision in rack logic-supply calculations.
04I/O restoration testingVerify link diagnostics and assigned field-signal operation together.

Why choose Nordwel

Configuration-aware supportReview the exact item, leftmost i/o-rack position; two 37-pin connections and installed-system requirements before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Match the complete supplied identity, board revision and installed circuit requirements before operational release.
Need help matching IC600BF830?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp