other
Products
Bently Nevada 3500/40M 135489-04 Proximitor I/O module with internal barriers product view
Bently Nevada 3500/40M 135489-04 Proximitor I/O module with internal barriers product view
Bently Nevada 3500/40M 135489-04 Proximitor I/O module with internal barriers product view

Bently Nevada 3500/40M 135489-04 Proximitor I/O module with internal barriers

EMAIL SALES
Bently Nevada 3500/40M
3500/40M 135489-04 - Proximitor I/O module with internal barriers

3500/40M 135489-04 combines Proximitor I/O with internal barriers. Its internal terminations must match the approved sensor circuits.

Bently Nevada3500/40MInternal-barrier Proximitor I/O
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
3500/40M 135489-04 product profile
ManufacturerBently Nevada
Exact model3500/40M 135489-04
TerminationInternal
Barrier arrangementInternal barriers
Measurement contextProximity monitoring
Monitor configurationTwo channel pairs
Field wiringInternal I/O terminals
Verified functionBarrier-equipped Proximitor I/O
  • Brand:

    Bently Nevada
  • Item NO.:

    3500/40M 135489-04
  • Part Number:

  • Weight:

  • Dimensions:

  • Manufacture Year:

  • Place of Origin:

  • Certification:

  • Description:

3500/40M 135489-04 configuration inquiry

Get a precise quote for 3500/40M 135489-04

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

3500/40M 135489-04 function and interfaces

3500/40M 135489-04 is a Proximitor I/O module with internal barriers for the 3500/40M installation. External termination blocks cannot be used with internal-termination I/O modules.

Barrier-equipped sensor interfaceConnect the proximity field circuit through the internal-barrier I/O arrangement.
Internal field terminationTerminate the approved sensor conductors at the I/O assembly rather than an external block.
Vibration and position signal routingSupport the proximity signals used by the configured front monitor.
Installation integrityPreserve the barrier-related wiring, grounding and approval conditions during service.

Installation and selection boundaries

  • This spare combines internal barriers with internal terminations for the Proximitor monitor installation.
  • External termination blocks cannot be used with internal-termination I/O modules.
  • Match the complete barrier installation and sensor circuit before assigning hazardous-area suitability; the spare name alone is insufficient.
Official product data

3500/40M 135489-04 key specifications

Component Proximitor I/O module
Barrier provision Internal barriers
Termination location Internal terminations
Associated signal class Proximity transducer signals
Monitor channel grouping Channels 1-2 and 3-4
Configuration method 3500 Rack Configuration Software
External termination blocks Not used with this internal-termination arrangement

Bently Nevada datasheet 141535 Rev. R, pages 1 and 9-10.

Pre-order check 01

Installation environment

Preserve the approved protection arrangement while installing the correct component and field connections.

  • Retain the approved sensor-loop, internal terminal and barrier installation records.
  • Isolate the affected loop and coordinate protection availability before removing the rear I/O.
  • Restore the internal terminations, shielding and grounding without substituting an external block arrangement.
  • Verify barrier installation integrity and the configured channel response before returning the monitor to service.
Keep the installed wiring and configuration records available for controlled commissioning checks.
Pre-order check 02

Compatibility confirmation

Review the complete identity together with the fitted interfaces and installed configuration.

Assembly identity
3500/40M 135489-04 with internal barriers and internal terminations.
Termination route
Use the installed internal I/O terminals; do not add external termination blocks.
Sensor circuits
Match the proximity transducer system and the approved barrier loop.
Measurement setup
Retain channel-pair programming, sensor sensitivity and front-monitor revision requirements.
Barrier installation
Confirm the actual approval label, grounding, environmental limits and installed loop requirements.
Match 3500/40M 135489-04 with the installed monitor, field wiring, configuration and applicable installation requirements.
Recommended model families

More Bently Nevada models

Bently Nevada selection 01Bently Nevada 330130-075-01-00Bently Nevada 330104-00-08-15-02-00Bently Nevada 330102-00-12-10-01-05

Confirm the complete order code and installed-system requirements before selecting a replacement.

Bently Nevada selection 02Bently Nevada 330103-02-04-10-02-CNBently Nevada 330103-02-08-10-02-CNBently Nevada 330905-00-25-05-02-CN

Confirm the complete order code and installed-system requirements before selecting a replacement.

Bently Nevada selection 03Bently Nevada 330903-00-07-10-01-CNBently Nevada 330903-00-07-10-01-00Bently Nevada 330876-03-10-00-00

Confirm the complete order code and installed-system requirements before selecting a replacement.

Bently Nevada selection 04Bently Nevada 330906-02-12-10-02-05Bently Nevada 330902-00-95-05-02-05Bently Nevada 330876-01-50-01-05

Confirm the complete order code and installed-system requirements before selecting a replacement.

Additional published brands

Additional Advantage Models

General ElectricGeneral Electric IC200UAL004General Electric IC200UAL005General Electric IC200UAL006

Confirm the complete order code and installed-system requirements before selecting a replacement.

General ElectricGeneral Electric IC200UAR028General Electric IC200UDD112General Electric IC200UDD120

Confirm the complete order code and installed-system requirements before selecting a replacement.

General ElectricGeneral Electric DS200AAHAH1AGeneral Electric DS200SVIAG1AGeneral Electric DS200SPCBG1A

Confirm the complete order code and installed-system requirements before selecting a replacement.

General ElectricGeneral Electric DS200SLCCG2AGeneral Electric DS200SHVIG1AGeneral Electric DS200PTCTG1A

Confirm the complete order code and installed-system requirements before selecting a replacement.

SiemensSiemens 6ES7144-4JF00-0AB0Siemens 6ES7144-4FF01-0AB0Siemens 6ES7144-1JB31-0XB0

Confirm the complete order code and installed-system requirements before selecting a replacement.

SiemensSiemens 6ES7144-1GB31-0XB0Siemens 6GK5308-2FM10-2AA3Siemens 6ES7143-5AH00-0BA0

Confirm the complete order code and installed-system requirements before selecting a replacement.

SiemensSiemens 6ES7143-4BF50-0AA0Siemens 6ES7142-6BH00-0AB0Siemens 6GK1143-0TA02

Confirm the complete order code and installed-system requirements before selecting a replacement.

SiemensSiemens 6GK1143-0AA01Siemens 6ES5951-7LB21Siemens 6ES5948-3UA23

Confirm the complete order code and installed-system requirements before selecting a replacement.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

3500/40M 135489-04 Order Guide

Selection checks for the complete 3500/40M 135489-04 identity and installed arrangement.
1Identify the complete assemblySpecify 3500/40M 135489-04 and retain the supplied hardware revision and installed rack position.
2Map the field connectionsUse the installed internal I/O terminals; do not add external termination blocks.
3Check the connected equipmentMatch the proximity transducer system and the approved barrier loop.
4Retain the configurationRetain channel-pair programming, sensor sensitivity and front-monitor revision requirements.
5Review site conditionsConfirm the actual approval label, grounding, environmental limits and installed loop requirements.
6Coordinate the replacementProvide the quantity, delivery destination and controlled verification requirements before the replacement window.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Check the complete ordering code and the installed interface requirements before selection.
General ElectricIC200BEM104

Match the complete model, revision and required installed function before ordering.

Specialist model
General ElectricIC200CHS003

Match the complete model, revision and required installed function before ordering.

Specialist model
General ElectricIC200UAA007

Match the complete model, revision and required installed function before ordering.

Specialist model
General ElectricDS200PLIBG1A

Match the complete model, revision and required installed function before ordering.

Specialist model
General ElectricDS200PANAH1A

Match the complete model, revision and required installed function before ordering.

Specialist model
General ElectricDS200FHVAG1A

Match the complete model, revision and required installed function before ordering.

Specialist model
Nordwel customer support

Company Services & FAQ

Practical support for 3500/40M 135489-04 selection, quotation and order coordination.

Company services

Component and installation checkReview the complete ordering identity, actual interfaces and installed configuration before quotation.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

3500/40M 135489-04 FAQ

What is integrated into 3500/40M 135489-04?The spare is a Proximitor I/O module with internal barriers and internal terminations. It provides the designated field interface; the front monitor still carries out the configured measurement and alarm processing.
Can external termination blocks be added to 3500/40M 135489-04?No. The installation uses internal terminations, and the monitor ordering guidance states that external termination blocks cannot be used with internal-termination I/O modules. Preserve the actual internal wiring arrangement.
Does 3500/40M 135489-04 automatically approve any hazardous-area sensor circuit?No. The barrier hardware must be matched to the approved sensor circuit and installation conditions. Check the supplied module label, grounding arrangement and applicable barrier requirements before accepting the complete loop.
Who performs the measurement processing when 3500/40M 135489-04 is fitted?The matched front Proximitor monitor conditions the signals and compares the selected measurements with configured alarm setpoints. This spare supplies the barrier-equipped I/O path, not a separate standalone processing channel.
Can channel-pair programming be ignored when changing 3500/40M 135489-04?The monitor channels are configured in pairs. Retain the existing pair assignments and required measurement functions so that the restored sensor wiring feeds the intended processing configuration.
What makes 3500/40M 135489-04 different from an unprotected terminal adapter?Its defined assembly includes internal barriers as part of the I/O arrangement. Replacement therefore needs a check of the barrier installation and sensor loop, not just a mechanical terminal-to-terminal match.
Should the front-monitor power figure be used for 3500/40M 135489-04 alone?Treat the front monitor and rear I/O as separate components when reviewing power and supply scope. A figure specified for the complete monitor does not describe the bare barrier I/O spare on its own.
How should proximity sensitivity be checked with 3500/40M 135489-04?Match the connected transducer system to the sensitivity selected in the front monitor for the actual measurement. Retaining the same I/O spare does not establish that a different sensor system has the correct scale factor.
What wiring records are important before removing 3500/40M 135489-04?Retain the sensor-loop assignment, internal terminal connections, shield and ground arrangements, and the approved barrier installation records. These identify the circuit that must be restored after the module is fitted.
What should the return-to-service check for 3500/40M 135489-04 include?Check the restored loop connections, monitor channel health, expected measurement response and the configured alarms under the approved test procedure. Confirm that the barrier installation remains intact before ending the maintenance bypass or outage.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
Bently Nevada 3500/40M support

Applications & Why Choose Nordwel

Engineering uses of 3500/40M 135489-04 within the matched monitoring installation.

Application areas

01Barrier-based proximity installationsProvide the I/O barrier arrangement specified for the installed proximity sensor circuits.
02Internal-termination rack panelsRetain the direct I/O wiring arrangement without introducing external termination blocks.
03Shaft-position measurement pathsInterface the proximity signals used by the configured thrust or expansion measurement.
04Controlled barrier-module replacementPreserve the approved sensor wiring and verify measurement recovery after replacing the I/O component.

Why choose Nordwel

Configuration-aware supportReview the component identity, fitted interfaces and installed monitoring arrangement before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Final selection depends on the complete ordering identity, hardware revision, connected interfaces and installed configuration.
Need help matching 3500/40M 135489-04 to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp