other
Products
ICS TRIPLEX TC-201-02-15M0 15 m internal-routing input cable product view
ICS TRIPLEX TC-201-02-15M0 15 m internal-routing input cable product view
ICS TRIPLEX TC-201-02-15M0 15 m internal-routing input cable product view

ICS TRIPLEX TC-201-02-15M0 15 m internal-routing input cable

EMAIL SALES
Trusted companion-slot cables
TC-201-02-15M0 — 15 m internal-routing input cable

TC-201-02-15M0 is an internal-routing companion-slot cable for a compatible forty-channel input and field termination assembly. Its 15.0 m length is at the manual’s recommended maximum, so the actual cabinet route and termination pairing should be checked before ordering.

ICS TRIPLEXTrusted companion-slot cables40-channel input-to-FTA companion-slot connectionInternal routing; LSZH insulation
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
TC-201-02-15M0 product profile
ManufacturerICS TRIPLEX
Exact modelTC-201-02-15M0
Product type15 m internal-routing input cable
Product familyTrusted companion-slot cables
Primary roleConnects a 40-channel input to its FTA
Interface contextInternal routing; LSZH insulation
  • Brand:

    ICS TRIPLEX
  • Item NO.:

    TC-201-02-15M0
TC-201-02-15M0 configuration inquiry

Get a precise quote for TC-201-02-15M0

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

15 m internal-routing input cable configuration

TC-201-02-15M0 is an internal-routing companion-slot cable for a compatible forty-channel input and field termination assembly. Its 15.0 m length is at the manual’s recommended maximum, so the actual cabinet route and termination pairing should be checked before ordering.

System roleTC-201-02-15M0 is an internal-routing companion-slot cable for a compatible forty-channel input and field termination assembly. Its 15.0 m length is at the manual’s recommended maximum, so the actual cabinet route and termination pairing should be checked before ordering.
Electrical integrationReview the actual input circuit, cable path and termination pairing; do not assign an independent power-supply function to the cable.
Configuration reviewMatch the input-side companion-slot arrangement and corresponding FTA connection.
CommissioningConfirm end-to-end circuit identity and connection integrity with the installed equipment isolated.

Engineering selection points

  • Cable application: 40-channel input-to-FTA companion-slot connection.
  • Routing arrangement: Internal.
  • Nominal cable length: 15.0 m.
  • Insulation option: 02: low-smoke zero-halogen.
Official product data

TC-201-02-15M0 key specifications

Cable application40-channel input-to-FTA companion-slot connection
Routing arrangementInternal
Nominal cable length15.0 m
Insulation option02: low-smoke zero-halogen
Recommended length ceiling15 m in the covered cable guidance

Technical reference: ICSTT-RM311 companion-slot-to-FTA cable manual and ordering guidance.

Pre-order check 01

Installation environment

Check the mounting, connection and operating conditions for this exact configuration before installation.

  • Measure the intended internal route including dressing and service allowance.
  • Identify both mating ends and preserve the channel-to-terminal allocation.
  • Protect the cable from sharp edges, excessive tension and connector loading.
  • Inspect the installed route and complete the approved circuit checks before reconnecting the input system.
Record the installed arrangement and the final controlled checks in the commissioning file.
Pre-order check 02

Compatibility confirmation

Match the complete item to its field interface, mechanical arrangement and configured system.

Complete item
Retain TC-201-02-15M0 and record the supplied board revision.
Installed assembly
Internal routing; LSZH insulation.
Electrical conditions
Review the actual input circuit, cable path and termination pairing; do not assign an independent power-supply function to the cable.
Configuration
Match the input-side companion-slot arrangement and corresponding FTA connection.
Acceptance
Confirm end-to-end circuit identity and connection integrity with the installed equipment isolated.
Match the complete supplied identity, board revision and installed circuit requirements before operational release.
Recommended model families

More ICS TRIPLEX and specialist models

Model selections 01ICS TRIPLEX T8451ICS TRIPLEX T8311CXICS TRIPLEX TC-203-02-10M5

Match the complete ordering code and installed-system requirements before selection.

Model selections 02Siemens 6ES7152-1BA00-0AB0Siemens 6ES7153-2BB00-0XB0Siemens 6ES7154-2AA01-0AB0

Match the complete ordering code and installed-system requirements before selection.

Model selections 03Siemens 6ES7155-5BA00-0AB0Siemens 6GK7177-1MA20-0AA0Siemens 6ES7143-5BF00-0BA0

Match the complete ordering code and installed-system requirements before selection.

Model selections 04Siemens 6ES7144-5KD00-0BA0Siemens 6ES7144-4PF00-0AB0Siemens 6ES7144-4JF00-0AB0

Match the complete ordering code and installed-system requirements before selection.

Additional published brands

Additional Advantage Models

Additional selections 01Siemens 6ES7144-4FF01-0AB0Siemens 6ES7144-1JB31-0XB0Siemens 6ES7144-1GB31-0XB0

Match the complete ordering code and installed-system requirements before selection.

Additional selections 02Siemens 6GK5308-2FM10-2AA3Siemens 6ES7143-5AH00-0BA0Siemens 6ES7143-4BF50-0AA0

Match the complete ordering code and installed-system requirements before selection.

Additional selections 03Siemens 6ES7142-6BH00-0AB0Siemens 6GK1143-0TA02Siemens 6GK1143-0AA01

Match the complete ordering code and installed-system requirements before selection.

Additional selections 04Siemens 6ES5951-7LB21Siemens 6ES5948-3UA23Siemens 6ES5948-3UA13

Match the complete ordering code and installed-system requirements before selection.

Additional selections 05Siemens 6ES5945-7UA23Siemens 6ES5941-7UA12Siemens 6ES5921-3WB12

Match the complete ordering code and installed-system requirements before selection.

Additional selections 06Siemens 6ES5541-8AA11Siemens 6ES5470-4UC13Siemens 6ES5465-4UA13

Match the complete ordering code and installed-system requirements before selection.

Additional selections 07Siemens 6ES5464-8MF21Siemens 6ES5464-8ME11Bently Nevada 330854-080-25-05

Match the complete ordering code and installed-system requirements before selection.

Additional selections 08Bently Nevada 330854-080-24-05Bently Nevada 330130-070-01-00Bently Nevada 330130-075-01-00

Match the complete ordering code and installed-system requirements before selection.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

TC-201-02-15M0 Order Guide

Match the complete configuration to the installed requirement before finalizing the order.
1Confirm the exact itemTC-201-02-15M0 — 15 m internal-routing input cable.
2Check the field interfaceInternal routing; LSZH insulation.
3Review the installationMeasure the intended internal route including dressing and service allowance.
4Match the configured systemRetain TC-201-02-15M0 and record the supplied board revision.
5Agree the supplied scopeConfirm the requested quantity, condition, package contents and destination with the quotation.
6Plan a controlled acceptanceMatch the complete supplied identity, board revision and installed circuit requirements before operational release.

Middle East Demand & Specialist Models

Selected published product references for regional projects and installed-system maintenance.

Published references for regional project selection.
Confirm the exact part number before ordering.
Siemens6ES7151-7AA00-0AB0

IM151-7 CPU interface module. Match the complete configuration and supplied scope.

Published model reference
Siemens6ES7151-7AA10-0AB0

IM151-7 CPU with MMC load memory. Match the complete configuration and supplied scope.

Published model reference
Siemens6ES7151-7AA11-0AB0

IM151-7 CPU with 64 KB working memory. Match the complete configuration and supplied scope.

Specialist brand
Siemens6ES7151-7FA21-0AB0

IM151-7F CPU interface module. Match the complete configuration and supplied scope.

Specialist brand
Siemens6ES7151-8AB00-0AB0

IM151-8 PN/DP CPU module. Match the complete configuration and supplied scope.

Specialist brand
Siemens6ES7152-1BA00-0AB0

IM152-1PN interface module. Match the complete configuration and supplied scope.

Specialist brand
Nordwel customer support

Company Services & FAQ

Configuration and order support for ICS TRIPLEX TC-201-02-15M0.

Company services

Model & configuration checkReview the complete item and internal routing; lszh insulation requirements before quotation.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

TC-201-02-15M0 FAQ

How long is TC-201-02-15M0?The 15M0 length field denotes 15.0 m. Include the intended cabinet route and service allowance when checking whether that length reaches both mating points.
Where is this cable intended to be routed?It is the internal-routing configuration of the covered companion-slot input cable. Plan the path within the installed cabinet arrangement and keep the connector transition free from strain.
What does the 02 cable option specify?The option identifies low-smoke zero-halogen insulation. It does not by itself establish an outdoor exposure rating, armor or a particular gland design.
Which circuit function uses this companion-slot cable?It carries the connection between a compatible forty-channel input arrangement and its field termination assembly. Select the matching input and termination pairing rather than treating the connectors as universal.
Does a 15 m cable leave room for an arbitrary extension?The covered guidance recommends a maximum cable length of 15 m. Assess the actual route within that limit; adding an extension or coupler creates a different installation that needs its own engineering assessment.
Should the cable be selected by connector appearance alone?No. Verify the companion-slot arrangement, input function and FTA pairing as well as the connector form. The same-looking connection does not prove identical circuit allocation.
What should be measured before the cable is ordered?Measure the full internal path, including bends, dressing and the space needed to reach the mating points without tension. A straight-line cabinet distance can underestimate the required route.
Can this cable be treated as an active diagnostic module?It is a cable assembly, not a powered processing or diagnostic module. Commissioning should focus on the route, connector condition and correct end-to-end input circuit connections.
How can connector damage be avoided during installation?Support the cable while mating and dressing it, keep pulling force off the connector body and avoid sharp-edge contact. Inspect both ends before the cabinet is closed.
What belongs in the cable acceptance file?Record the complete cable designation, route, mating points and circuit-check results. Retain photographs or routing drawings that make later input-channel identification unambiguous.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
ICS TRIPLEX Trusted companion-slot cables

Applications & Why Choose Nordwel

Engineering contexts for TC-201-02-15M0 and the available order-coordination support.

Application areas

01Internal input marshallingConnect the approved input companion-slot arrangement to its field termination.
02Long cabinet cable routesCheck the complete 15 m path before agreeing the spare length.
03Low-smoke insulation requirementsRetain the specified LSZH construction in the cable selection.
04Input-circuit maintenancePreserve end-to-end terminal allocation during cabinet work.

Why choose Nordwel

Configuration-aware supportReview the exact item, internal routing; lszh insulation and installed-system requirements before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Match the complete supplied identity, board revision and installed circuit requirements before operational release.
Need help matching TC-201-02-15M0?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp