other
Products
ABB ACS510-01-031A-4 15 kW wall-mounted variable-speed drive product views
ABB ACS510-01-031A-4 15 kW wall-mounted variable-speed drive product views
ABB ACS510-01-031A-4 15 kW wall-mounted variable-speed drive product views

ABB ACS510-01-031A-4 15 kW wall-mounted variable-speed drive

EMAIL SALES
ABB ACS510
ACS510-01-031A-4 — wall-mounted variable-speed drive

ACS510-01-031A-4 is an ABB ACS510 wall-mounted drive for normal pump and fan duty. Its published ratings are 31 A continuous output and 15 kW typical motor power at 400 V.

ABBACS510Wall-mounted AC drive
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
ACS510-01-031A-4 product profile
Product familyACS510
Exact modelACS510-01-031A-4
Typical motor power15 kW at 400 V, normal use
Continuous output current31 A RMS
Frame sizeR3
Basic protectionIP21
  • Brand:

    ABB
  • Item NO.:

    ACS510-01-031A-4
  • Part Number:

  • Weight:

  • Dimensions:

  • Manufacture Year:

  • Place of Origin:

  • Certification:

  • Description:

ACS510-01-031A-4 configuration inquiry

Get a precise quote for ACS510-01-031A-4

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

ACS510-01-031A-4 functions and installation

The ACS510-01-031A-4 operates from a three-phase 380–480 VAC supply and uses the R3 frame with an IP21 basic enclosure. ABB lists 31 A continuous output and 15 kW typical motor power at 400 V for normal use. Embedded Modbus over RS485 supports integration with an appropriately configured control system. Selection must account for the motor nameplate, actual duty, cooling conditions and any required derating rather than relying on power alone.

Motor speed regulationControls the speed of a suitably selected motor in normal pump and fan applications.
Process controlSupports a commissioned process-control arrangement using correctly scaled references and feedback.
Network integrationEmbedded Modbus over RS485 requires matching network settings and suitable wiring.
Installation planningR3 cooling, cable routing and protective earthing must be accommodated before commissioning.

Installation and selection boundaries

  • 15 kW is the typical motor-power figure at 400 V for normal use; 31 A is the continuous output-current rating.
  • The R3 cooling figures are 457 W heat dissipation and 134 m³/h airflow; keep the specified cooling space available.
  • The basic IP21 enclosure and three-phase supply rating must be matched to the actual installation environment and electrical supply.
Official product data

ACS510-01-031A-4 key specifications

Supply voltage Three-phase 380–480 VAC
Typical motor power 15 kW at 400 V, normal use
Continuous output current 31 A RMS
Frame size R3
Basic enclosure protection IP21
Input frequency 48–63 Hz
Heat dissipation 457 W
Cooling airflow 134 m³/h
Embedded communication Modbus over RS485

Source: ABB ACS510 technical catalogue, 3ABD00017601 Rev D, ratings and technical-data tables; ABB ACS510-01 User’s Manual, Rev D.

Pre-order check 01

Installation environment

Plan the mounting, supply and motor connections for ACS510-01-031A-4 before an authorized commissioning trial.

  • Mount in the permitted orientation and maintain 200 mm free cooling space above and below the drive.
  • Verify the three-phase supply, protective earthing and motor-circuit connections before energizing.
  • Separate input, motor and control wiring as required for electrical safety and EMC performance.
  • Commission with the actual motor nameplate data, selected command source and process interlocks checked.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Electrical supply
Three-phase 380–480 VAC, 48–63 Hz; confirm the actual site supply.
Motor and load
Assess motor nameplate current and normal-duty load against the 31 A continuous output rating.
Thermal environment
Allow for 457 W heat dissipation, 134 m³/h airflow and derating where operating conditions require it.
Control integration
Match I/O signal configuration, command sources and embedded RS485 Modbus settings to the control system.
Braking arrangement
The R3 frame requires an appropriately selected external arrangement when resistor braking is needed.
Use the complete ACS510-01-031A-4 ordering code together with the connected motor, process duty and accepted commissioning configuration when planning supply or replacement.
Recommended model families

More ABB models

ABBABB ACS510-01-09A4-4ABB ACS510-01-012A-4ABB ACS510-01-017A-4

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB ACS355-03E-04A1-4ABB ACS355-03E-07A3-4ABB ACS355-03E-08A8-4

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB ACS355-03E-12A5-4ABB ACS355-03E-15A6-4ABB ACS355-03E-23A1-4

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB ACS355-03E-31A0-4ABB PM5132-T-ETHABB PM5112-R-ETH

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

Bently NevadaBently Nevada 330854-080-25-05Bently Nevada 330854-080-24-05Bently Nevada 330130-070-01-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330130-075-01-00Bently Nevada 330104-00-08-15-02-00Bently Nevada 330102-00-12-10-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330103-02-04-10-02-CNBently Nevada 330103-02-08-10-02-CNBently Nevada 330905-00-25-05-02-CN

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330903-00-07-10-01-CNBently Nevada 330903-00-07-10-01-00Bently Nevada 330876-03-10-00-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330906-02-12-10-02-05Bently Nevada 330902-00-95-05-02-05Bently Nevada 330876-01-50-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330851-01-000-020-10-00-00Bently Nevada 330879-03-00Bently Nevada 330851-02-000-040-10-00-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330180-X1-05 MOD 145004-75Bently Nevada 330851-02-000-080-90-01-05Bently Nevada 24701-28-05-XX-014-04-XX MOD 323933-40-02

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 24701-28-05-XX-025-04-XX MOD 323933-30-02Bently Nevada 129716-XXX-040-15 MOD 166797-0133Bently Nevada 24701-28-05-XX-104-03-XX MOD 323933-00-02

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

ACS510-01-031A-4 Order Guide

Check the complete requested item against the actual installation before ordering.
1Confirm identityRequest the complete ACS510-01-031A-4 code and the required supplied scope.
2Check motor and dutyCompare motor current and load with the 31 A rating and normal-duty application.
3Review site supplyConfirm the three-phase voltage and frequency before selection.
4Plan mounting and coolingAllow R3 mounting space and 457 W heat removal with the required cooling clearance.
5Record control requirementsCapture terminal assignments, reference sources and communication settings.
6Arrange acceptance checksAgree the identity, supplied items and controlled commissioning checks before ordering.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
ABBPM5072-T-ETH

A separate product reference; verify its own installation and configuration.

Specialist model
ABBPM5072-R-ETH

A separate product reference; verify its own installation and configuration.

Specialist model
ABBIM60

A separate product reference; verify its own installation and configuration.

Specialist model
ABBSDCS-UCM-1-COAT 3ADT220090R0008

A separate product reference; verify its own installation and configuration.

Specialist model
ABBIIMKM02A

A separate product reference; verify its own installation and configuration.

Specialist model
ABBDO525

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for ACS510-01-031A-4 selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

ACS510-01-031A-4 FAQ

How should I interpret the 15 kW rating of ACS510-01-031A-4?15 kW is the typical motor power at 400 V for normal pump and fan duty. The continuous output-current rating is 31 A. Check the motor nameplate current and actual load as well as power; the kW figure alone does not establish suitability for a different duty or operating condition.
Which supply is required for ACS510-01-031A-4?The drive is rated for a three-phase 380–480 VAC supply at 48–63 Hz. Confirm the site supply before connecting the input terminals. A single-phase connection or a supply outside this range is not established by this rating.
How much cooling clearance does ACS510-01-031A-4 need?Keep 200 mm of free space above and below the drive for cooling airflow. Do not obstruct the air path with cable ducts or adjacent equipment. Allow additional practical access for cable terminations, inspection and service without reducing that cooling space.
What ventilation allowance applies to ACS510-01-031A-4?ABB lists 457 W of heat dissipation and 134 m³/h of cooling airflow for this R3 drive. Enclosure ventilation must remove the generated heat while maintaining acceptable inlet-air conditions. These figures do not mean that a sealed cabinet can dissipate the heat without a thermal assessment.
Is the basic ACS510-01-031A-4 enclosure suitable for an exposed outdoor position?The basic unit has IP21 protection. That designation does not establish protection against outdoor weather, water jets or the contamination conditions of every plant area. Use an installation location and enclosure arrangement appropriate to the actual environment while preserving the required ventilation.
Does pressing Stop make ACS510-01-031A-4 safe to wire?No. A panel Stop command does not isolate hazardous voltage. Electrical work requires qualified personnel, isolation of the relevant power sources, a wait of at least five minutes for the DC circuit to discharge, and verification that hazardous voltage is absent before touching connections.
Can ACS510-01-031A-4 use a resistor as though it had a built-in brake chopper?Do not assume that arrangement. The R3 frame does not inherit the internal brake-chopper arrangement of smaller frames. An application requiring resistor braking needs a suitable external braking unit or chopper and resistor arrangement, selected and connected for the drive and load.
Which motor values should be entered when commissioning ACS510-01-031A-4?Enter the motor nameplate data required by the startup parameters, including rated voltage and current. Use the actual connected motor values rather than the drive catalogue power as a substitute. The drive cannot provide a motor output voltage higher than its available supply voltage.
How should power and signal wiring be arranged around ACS510-01-031A-4?Route input power, motor and control wiring with the separation and shielding required for the installation. Terminate protective earth correctly and keep sensitive signal circuits away from power-cable coupling. Cable selection must address electrical safety and EMC together rather than relying only on cable length.
What should be checked before ACS510-01-031A-4 starts the pump or fan?Check wiring, protective earthing, motor data, the selected control source and the process interlocks before an authorized trial. Then verify rotation and commanded response under controlled conditions. Confirm that the process can tolerate the trial and that an unexpected remote start is prevented during preparation.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
ABB ACS510

Applications & Why Choose Nordwel

Application and maintenance planning for ACS510-01-031A-4 in the correctly matched installation.

Application areas

01Pump speed controlRegulates a suitably matched pump motor using a commissioned reference and the required process safeguards.
02Fan-duty installationsSupports normal fan applications where motor current, airflow and site conditions fit the drive ratings.
03Process-feedback regulationUses correctly scaled process feedback and PID settings where the application calls for closed-loop regulation.
04Controlled replacementRetain the installed motor, wiring and accepted parameter records so replacement work can be checked before restart.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Use the complete ACS510-01-031A-4 ordering code together with the connected motor, process duty and accepted commissioning configuration when planning supply or replacement.
Need help matching ACS510-01-031A-4 to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp