other
Products
General Electric IC600PM500 AC-input CPU/DPU power supply product views
General Electric IC600PM500 AC-input CPU/DPU power supply product views
General Electric IC600PM500 AC-input CPU/DPU power supply product views

General Electric IC600PM500 AC-input CPU/DPU power supply

EMAIL SALES
General Electric Series Six
IC600PM500 — AC-input CPU/DPU power supply

Supply the Series Six CPU/DPU rack from the specified AC input configuration. Assess each DC output and the combined output-power limit before accepting the connected backplane load.

General ElectricSeries SixAC-input CPU/DPU power supply
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
IC600PM500 product profile
Product familySeries Six
Exact modelIC600PM500
Rack applicationCPU/DPU
Input range95–260 VAC
Input frequency47–63 Hz
Combined output limitLess than 90 W
  • Brand:

    General Electric
  • Item NO.:

    IC600PM500
  • Part Number:

  • Weight:

  • Dimensions:

  • Manufacture Year:

  • Place of Origin:

  • Certification:

  • Description:

IC600PM500 configuration inquiry

Get a precise quote for IC600PM500

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

IC600PM500 functions and installation

IC600PM500 supplies the CPU/DPU rack with +5, +12 and −12 VDC outputs. The original GEK-83505 data specifies a 95–260 VAC input at 47–63 Hz and requires the total power drawn from all outputs to remain below 90 W.

Rack electronics supplyPowers the CPU/DPU backplane circuits.
Multi-rail outputProvides the three specified DC supply rails.
Processor controlsIncludes the RUN/STOP and memory-protection key controls.
Power supervisionThe POWER indication relates to the DC output voltage condition.

Installation and selection boundaries

  • Check individual rail limits and keep combined output power below 90 W.
  • A matching DC voltage does not establish interchangeability with an I/O-rack power supply.
  • Record the operating and memory-protection settings before a controlled exchange.
Official product data

IC600PM500 key specifications

Input voltage 95–260 VAC
Input frequency 47–63 Hz
DC outputs +5 V, +12 V and −12 V
Combined output power Less than 90 W across all outputs
+5 V output limit 16.5 A maximum
+12 V output limit 1.5 A maximum
−12 V output limit 1.0 A maximum
Operating temperature 0 to +60 °C outside the rack
Humidity 5–95%, non-condensing

GEK-83505 CPU/DPU Power Supply Module data sheet in the user-approved GEK-25367E original-manual archive.

Pre-order check 01

Installation environment

Prepare the fitted Series Six installation for a controlled exchange.

  • Secure the process, stop the system as required and isolate all affected supplies before terminal work.
  • Record the AC input, grounding, backplane wiring and any auxiliary battery connection.
  • Check the CPU/DPU rack role, output loads and permitted ambient conditions.
  • Restore the approved wiring and key settings, then verify power indication and controlled processor operation.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Rack purpose
Use the supply in the supported CPU/DPU rack arrangement.
Input circuit
Match the installed AC supply to the documented voltage and frequency range.
Output loading
Assess +5, +12 and −12 V loads individually and against the combined power limit.
Controls and retention
Preserve the required RUN/STOP, memory-protection and battery arrangements.
Hardware revision
Compare the fitted power unit, connection arrangement and supplied revision.
Confirm the supplied scope, installed revision and required functional checks before operational release.
Recommended model families

More General Electric models

General ElectricGeneral Electric IC600BF908General Electric IC600BF914General Electric IC600BF915

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600BF923General Electric IC600BF940General Electric IC600BF941

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600BF942General Electric IC600BF948General Electric IC600CB504

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600CB507General Electric IC600CB513General Electric IC600CB516

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

SiemensSiemens 6ES7144-4JF00-0AB0Siemens 6ES7144-4FF01-0AB0Siemens 6ES7144-1JB31-0XB0

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES7144-1GB31-0XB0Siemens 6GK5308-2FM10-2AA3Siemens 6ES7143-5AH00-0BA0

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES7143-4BF50-0AA0Siemens 6ES7142-6BH00-0AB0Siemens 6GK1143-0TA02

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB V18345-1010261001ABB 3HAC061275-001ABB PM5132-T-ETH

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB PM5112-R-ETHABB PM5072-T-ETHABB PM5072-R-ETH

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB IM60ABB SDCS-UCM-1-COAT 3ADT220090R0008ABB IIMKM02A

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB DO525ABB CM576-PNIOABB DI525

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330854-080-25-05Bently Nevada 330854-080-24-05Bently Nevada 330130-070-01-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

IC600PM500 Order Guide

Check the complete requested item against the actual installation before ordering.
1Identify the itemRetain IC600PM500 and the fitted revision when agreeing the replacement.
2Match the installed roleUse the supply in the supported CPU/DPU rack arrangement.
3Record connectionsRecord the AC input, grounding, backplane wiring and any auxiliary battery connection.
4Review operating limitsCheck individual rail limits and keep combined output power below 90 W.
5Agree the supplied scopeCompare the fitted power unit, connection arrangement and supplied revision.
6Validate restorationRestore the approved wiring and key settings, then verify power indication and controlled processor operation.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
General ElectricIC600BF830

A separate product reference; verify its own installation and configuration.

Specialist model
General ElectricIC600CB525

A separate product reference; verify its own installation and configuration.

Specialist model
General ElectricIC600CB536

A separate product reference; verify its own installation and configuration.

Specialist model
General ElectricIC600CB537

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7143-5BF00-0BA0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-5KD00-0BA0

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for IC600PM500 selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

IC600PM500 FAQ

What AC input range is specified for IC600PM500?GEK-83505 specifies 95–260 VAC at 47–63 Hz. Check the actual input circuit and protective arrangement against both voltage and frequency.
Which DC rails does the CPU/DPU AC supply provide?The outputs are +5 VDC, +12 VDC and −12 VDC. Match each backplane load to its correct rail and the corresponding current limit.
Can every individual output-current maximum be used simultaneously?Not if their combined power reaches the overall limit. The total output power must remain below 90 W, so a rail-by-rail current check is not sufficient on its own.
What current ceiling applies to the +5 V rail?The listed maximum is 16.5 A. The other output loads must still be included in the combined power assessment.
Is this CPU/DPU supply automatically suitable for an I/O rack?No. Match the power-supply role, backplane and connection arrangement. Similar output voltages do not establish an unconditional rack replacement.
What do the two processor-related key switches control?The front controls provide CPU RUN/STOP selection and memory protection. Record their required operating positions before replacement and restore them under the site procedure.
What does the POWER light indicate on this supply?The manual associates an illuminated POWER light with all three DC outputs being within tolerance. An unlit indication can mean at least one output is too low; it is not a substitute for the required electrical checks.
Which ambient conditions are stated for the AC CPU supply?The operating temperature is 0 to +60 °C outside the rack, with 5–95% non-condensing humidity. Assess the actual installed environment and cooling conditions.
Which connections need to be recorded before disconnecting this unit?Identify the incoming AC supply, protective ground, backplane connections and any auxiliary battery wiring. Preserve terminal assignments rather than relying on wire position alone.
What should be checked when the processor does not recover after a supply exchange?Verify the input circuit, output conditions, backplane wiring and required key-switch positions. Then review the retained application and processor diagnostics before restoring normal control.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
General Electric Series Six

Applications & Why Choose Nordwel

Application and maintenance planning for IC600PM500 in the correctly matched installation.

Application areas

01CPU/DPU power restorationReplace the correct AC-fed rack supply under a controlled procedure.
02Backplane load assessmentCheck individual rail currents and combined output power.
03Retention and control reviewPreserve battery wiring and processor key-control settings.
04Processor acceptanceConfirm the power condition and tested system response.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Confirm the supplied scope, installed revision and required functional checks before operational release.
Need help matching IC600PM500 to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp