6ES7157-1AB00-0AB0 — IM 157-1 PN interface module

Connect an ET 200AL installation to PROFINET through the IM 157-1 PN interface. Separate the electronics supply, passed-through load power and configured I/O data when reviewing the installation.

SiemensET 200ALIM 157-1 PN interface module
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
6ES7157-1AB00-0AB0 product profile
Product familyET 200AL
Exact model6ES7157-1AB00-0AB0
NetworkPROFINET IO; 100BASE-TX
Supply24 VDC; permitted range 20.4–28.8 VDC
Network connectors2 D-coded M12 connections
Rated interface current100 mA
  • Brand:

    SIEMENS
  • Item NO.:

    6ES7157-1AB00-0AB0
6ES7157-1AB00-0AB0 configuration inquiry

Get a precise quote for 6ES7157-1AB00-0AB0

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

6ES7157-1AB00-0AB0 functions and installation

The interface provides two D-coded M12 PROFINET connections using 100BASE-TX. Its 24 VDC power arrangement distinguishes the interface current demand from the 1L+ and 2L+ power paths, each of which has its own 4 A pass-through limit.

PROFINET couplingConnects ET 200AL field I/O to the controller.
Rugged connectionUses D-coded M12 network connectors.
Power-path planningAssess 1L+ and 2L+ loading independently of electronics demand.
Configured exchangeMatch the station data allocation to the controller project.

Installation and selection boundaries

  • Do not interpret a 4 A pass-through limit as interface self-consumption.
  • Retain the permitted supply range at the module under the intended load.
  • Check the installed software and device-description support before configuring the station.
Official product data

6ES7157-1AB00-0AB0 key specifications

Network PROFINET IO; 100BASE-TX
Supply 24 VDC; permitted range 20.4–28.8 VDC
Network connectors 2 D-coded M12 connections
Rated interface current 100 mA
1L+ power pass-through Maximum 4 A
2L+ power pass-through Maximum 4 A
Typical power loss 2.9 W
Maximum station I/O area 1430 bytes
Enclosure protection IP67

Siemens ET 200AL IM 157-1 PN equipment manual; technical, connection and engineering-support sections.

Pre-order check 01

Installation environment

Prepare the installed ET 200AL assembly for a controlled component exchange.

  • Secure the process and isolate the affected electronics and load-power circuits.
  • Label the two M12 network connections and the 1L+/2L+ power arrangement.
  • Check voltage, cable condition, connector sealing and the loading of each power path.
  • Restore the PROFINET device configuration and test the mapped ET 200AL signals.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Station identity
Match the IM 157-1 PN device entry and fitted hardware.
Network connection
Use the correct D-coded M12 arrangement and engineered PROFINET topology.
Power distribution
Check both passed-through power paths and their connected loads separately.
Engineering support
Confirm the supported GSDML and engineering-software release for the installed firmware.
Commissioning
Validate station diagnostics, data allocation and controlled field-signal operation.
Release the installation only after its configured function and required acceptance checks agree.
Recommended model families

More Siemens models

SiemensSiemens 6ES7143-4BF50-0AA0Siemens 6ES7142-6BH00-0AB0Siemens 6GK1143-0TA02

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6GK1143-0AA01Siemens 6ES5951-7LB21Siemens 6ES5948-3UA23

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES5948-3UA13Siemens 6ES5945-7UA23Siemens 6ES5941-7UA12

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES5921-3WB12Siemens 6ES5541-8AA11Siemens 6ES5470-4UC13

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

ABBABB PM5132-T-ETHABB PM5112-R-ETHABB PM5072-T-ETH

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB PM5072-R-ETHABB IM60ABB SDCS-UCM-1-COAT 3ADT220090R0008

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB IIMKM02AABB DO525ABB CM576-PNIO

Separate product references; inclusion does not establish compatibility or interchangeability.

ABB / General ElectricABB DI525General Electric DS200SHVIG1AGeneral Electric DS200PTCTG1A

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric DS200PLIBG1AGeneral Electric DS200PANAH1AGeneral Electric DS200FHVAG1A

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric DS200FCGDH1AGeneral Electric DS200EXPSG1ABBGeneral Electric DS200EXDEG1A

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric DS200DMCBG2AKGGeneral Electric DS200DMCBG2AGeneral Electric DS200ACNAG1A

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric DS200AAHAH1AGeneral Electric DS200SVIAG1AGeneral Electric DS200SPCBG1A

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

6ES7157-1AB00-0AB0 Order Guide

Check the complete requested item against the actual installation before ordering.
1Identify the itemUse 6ES7157-1AB00-0AB0 and record the fitted hardware revision before selecting the supplied scope.
2Define the stationMatch the IM 157-1 PN device entry and fitted hardware.
3Check connectionsLabel the two M12 network connections and the 1L+/2L+ power arrangement.
4Review operating limitsDo not interpret a 4 A pass-through limit as interface self-consumption.
5Agree the supplied scopeValidate station diagnostics, data allocation and controlled field-signal operation.
6Validate the installationRestore the PROFINET device configuration and test the mapped ET 200AL signals.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
Siemens6ES7143-5BF00-0BA0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-5KD00-0BA0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-4PF00-0AB0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-4JF00-0AB0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-4FF01-0AB0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-1JB31-0XB0

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for 6ES7157-1AB00-0AB0 selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

6ES7157-1AB00-0AB0 FAQ

What network connectors are fitted to 6ES7157-1AB00-0AB0?The interface has two D-coded M12 connections for PROFINET using 100BASE-TX. Match connector coding, cabling and topology to the installed network.
Does the 4 A figure describe the IM 157-1 PN electronics demand?No. The 4 A maximum applies separately to the 1L+ and 2L+ power pass-through paths. The rated interface current is 100 mA, so these are different parts of the power assessment.
Which DC supply range should be present at the ET 200AL interface?The rated supply is 24 VDC and the permitted range is 20.4–28.8 VDC. Check the module-side voltage with the intended cable and load arrangement.
How large can the station I/O address area be?The maximum stated station area is 1430 bytes. Confirm the actual mapped data and supported configuration in the controller project.
Which engineering support should be checked before station configuration?The manual lists GSDML 2.3.1 and support from TIA Portal V13 SP1 or STEP 7 V5.5 SP4 HF3 under the stated configuration conditions. Match the actual software, device description and firmware combination.
What enclosure protection is specified for the interface?The interface is specified as IP67. Retaining that protection in service depends on correct mating connectors, sealing and installation of the field cables.
What heat contribution is stated for the IM 157-1 PN?The typical power loss is 2.9 W. Include the interface and other installed components in the environmental assessment of the mounting location.
Should 1L+ and 2L+ loads be assessed as a single unrestricted feed?Review the two paths independently and keep each within its own pass-through limit. Trace the actual connected loads and protective arrangement from the field power drawing.
What should be recorded before disconnecting the M12 field assembly?Record network-port routing, power-path connections, device identity and the mapped field-signal configuration. Preserve connector coding and sealing details during the exchange.
What remains to be checked after PROFINET communication is restored?Verify the device diagnostic state and intended I/O allocation, then test the connected field signals under controlled conditions. Communication recovery does not by itself confirm the process wiring or signal mapping.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
Siemens ET 200AL

Applications & Why Choose Nordwel

Application and maintenance planning for 6ES7157-1AB00-0AB0 in the correctly matched installation.

Application areas

01Distributed field I/OConnect an ET 200AL installation to the PROFINET controller.
02Field power reviewsSeparate electronics demand from each passed-through load-power path.
03M12 network maintenancePreserve connector coding, routing and sealing during exchange.
04Station commissioningVerify device configuration and actual signal behavior before release.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Release the installation only after its configured function and required acceptance checks agree.
Need help matching 6ES7157-1AB00-0AB0 to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp