other
Products
ABB PM583-ETH-XC controller CPU product views
ABB PM583-ETH-XC controller CPU product views
ABB PM583-ETH-XC controller CPU product views

ABB PM583-ETH-XC controller CPU

EMAIL SALES
ABB AC500-XC
PM583-ETH-XC — controller CPU

PM583-ETH-XC is an AC500-XC controller CPU with 1024 kB of user program memory and a separate 1024 kB integrated user-data allocation. It provides Ethernet and configurable serial interfaces for the approved control installation.

ABBAC500-XCcontroller CPU
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
PM583-ETH-XC product profile
Product familyAC500-XC
Exact modelPM583-ETH-XC
Program memory1024 kB
User data memory1024 kB
Ethernet interfacesOne
Local operationLC display and eight function keys
  • Brand:

    ABB
  • Item NO.:

    PM583-ETH-XC
  • Part Number:

  • Weight:

  • Dimensions:

  • Manufacture Year:

  • Place of Origin:

  • Certification:

  • Description:

PM583-ETH-XC configuration inquiry

Get a precise quote for PM583-ETH-XC

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

PM583-ETH-XC functions and installation

PM583-ETH-XC is an AC500-XC controller CPU with 1024 kB of user program memory and a separate 1024 kB integrated user-data allocation. It provides Ethernet and configurable serial interfaces for the approved control installation. Runs the engineered control program within its specified memory resources. Separates program storage from user-data allocation and the saved data portion.

Application processingRuns the engineered control program within its specified memory resources.
Data handlingSeparates program storage from user-data allocation and the saved data portion.
Connection planningCoordinate the Ethernet and two configurable serial interfaces with the actual terminal base.
Controlled commissioningRestore the accepted project and validate machine functions after any processor change.

Installation and selection boundaries

  • Supply voltage: 24 VDC.
  • Data buffering: Battery.
  • A compatible mechanical assembly still requires project, firmware and functional acceptance checks.
Official product data

PM583-ETH-XC key specifications

Supply voltage 24 VDC
User program memory 1024 kB, Flash EPROM and RAM
Integrated user data memory 1024 kB; 288 kB saved
Ethernet interface One
Serial interfaces Two configurable RS232/RS485
Minimum binary instruction time 0.05 microseconds
Local display LC display with eight function keys
Data buffering Battery

Source: ABB PLC Automation main catalogue, 3ADR020077C0204 Rev B, ordering data and technical tables, PDF pages 134,145.

Pre-order check 01

Installation environment

Prepare the installation and controlled change plan for PM583-ETH-XC.

  • Check the approved CPU/base combination, cabinet mounting, ventilation and access to the actual connectors.
  • Make affected circuits safe and verify the specified DC supply, polarity and protective-earth arrangement before connecting.
  • Retain a controlled project backup and record network addresses, serial settings and installed expansion hardware.
  • Restore the approved application in a safe state, inspect diagnostics and verify the required I/O and communication functions.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

System build
Check the selected AC500-XC base, processor revision and expansion hardware as one installation.
Retained data
Review the 288 kB saved portion separately from the complete 1024 kB user-data allocation.
Project timing
Validate actual task and I/O timing; the minimum instruction figure is not a full scan-time guarantee.
Communication
Retain electrical modes, addresses and protocol settings for the actual network and serial devices.
Replacement control
A compatible mechanical assembly still requires project, firmware and functional acceptance checks.
Confirm the complete item, installed arrangement and controlled acceptance results before normal operation.
Recommended model families

More ABB models

ABBABB 3HAC061275-001ABB PM5132-T-ETHABB PM5112-R-ETH

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB PM5072-T-ETHABB PM5072-R-ETHABB IM60

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB SDCS-UCM-1-COAT 3ADT220090R0008ABB IIMKM02AABB DO525

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB CM576-PNIOABB DI525ABB V18345-1010261001

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

HoneywellHoneywell MLF-DC04CHoneywell MLF-DV04AHoneywell MLF-DV04C

Separate product references; inclusion does not establish compatibility or interchangeability.

HoneywellHoneywell MLF-HD02AHoneywell MLF-PD02AHoneywell MLF-RD04A

Separate product references; inclusion does not establish compatibility or interchangeability.

HoneywellHoneywell MLF-TC04SHoneywell MLI-DN10EHoneywell MLI-DN14E

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330854-080-25-05Bently Nevada 330854-080-24-05Bently Nevada 330130-070-01-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330130-075-01-00Bently Nevada 330104-00-08-15-02-00Bently Nevada 330102-00-12-10-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330103-02-04-10-02-CNBently Nevada 330103-02-08-10-02-CNBently Nevada 330905-00-25-05-02-CN

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330903-00-07-10-01-CNBently Nevada 330903-00-07-10-01-00Bently Nevada 330876-03-10-00-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330906-02-12-10-02-05Bently Nevada 330902-00-95-05-02-05Bently Nevada 330876-01-50-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

PM583-ETH-XC Order Guide

Check the complete requested item against the actual installation before ordering.
1Record the identityKeep PM583-ETH-XC and the supplied revision on the maintenance record.
2Check the systemCheck the selected AC500-XC base, processor revision and expansion hardware as one installation.
3Prepare the mountingCheck the approved CPU/base combination, cabinet mounting, ventilation and access to the actual connectors.
4Plan the connectionsMake affected circuits safe and verify the specified DC supply, polarity and protective-earth arrangement before connecting.
5Control the changeRetain a controlled project backup and record network addresses, serial settings and installed expansion hardware.
6Verify operationRestore the approved application in a safe state, inspect diagnostics and verify the required I/O and communication functions.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
HoneywellMEL-BSSRT

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMEL-BSSRT-CC

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-AH04A

A separate product reference; verify its own installation and configuration.

Specialist model
Bently Nevada330851-01-000-020-10-00-00

A separate product reference; verify its own installation and configuration.

Specialist model
Bently Nevada330879-03-00

A separate product reference; verify its own installation and configuration.

Specialist model
Bently Nevada330851-02-000-040-10-00-05

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for PM583-ETH-XC selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

PM583-ETH-XC FAQ

How are program and user-data memory distinguished on PM583-ETH-XC?There is 1024 kB of program memory and a separate 1024 kB integrated user-data allocation. The user-data figure must not be added to the program-memory limit when sizing an application.
What does the 288 kB saved figure mean for PM583-ETH-XC data planning?It identifies the saved part of the integrated user-data allocation. Review which application values require retention instead of assuming that every working value has the same saved-data treatment.
Does the minimum instruction time describe the complete PM583-ETH-XC scan?No. The 0.05 microsecond figure is the minimum binary-instruction time. Actual task duration also depends on the executed program, scheduling, data handling and I/O or communication work.
How many Ethernet interfaces are available on PM583-ETH-XC?The CPU arrangement has one Ethernet interface. Match the actual base connection and project network settings; an expansion module's additional ports are a separate part of the station.
Why should the serial electrical mode be recorded for PM583-ETH-XC?Its two serial interfaces can be configured for RS232 or RS485. The chosen mode and the connected device's wiring must agree before communication is tested.
What is the role of the display during PM583-ETH-XC troubleshooting?The LC display and eight function keys provide local access to operating, status and diagnostic information. Interpret that information with the project state and circuit tests rather than using display activity as proof of correct control operation.
What supply check is required before energizing PM583-ETH-XC?Verify the prescribed 24 VDC input, correct polarity and the installation's protective arrangements. Account for the complete station power requirement separately from the CPU voltage designation.
Can an existing application be loaded into PM583-ETH-XC without a compatibility review?First check the processor target, hardware revision, engineering configuration and required firmware. A successful file transfer does not establish that all configured I/O and communication features match the installed station.
How should expansion hardware be handled during a PM583-ETH-XC replacement?Record every installed module and its position before the CPU is removed. Preserve the accepted station arrangement and compare the restored configuration with the actual hardware before outputs are enabled.
Which results should be recorded after commissioning PM583-ETH-XC?Record the accepted project version, restored network settings, diagnostic state and the results of the required machine-function tests. Keep these with the complete CPU identity and the maintenance change record.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
ABB AC500-XC

Applications & Why Choose Nordwel

Application and maintenance planning for PM583-ETH-XC in the correctly matched installation.

Application areas

01Application processingRuns the engineered control program within its specified memory resources.
02Data handlingSeparates program storage from user-data allocation and the saved data portion.
03Connection planningCoordinate the Ethernet and two configurable serial interfaces with the actual terminal base.
04Controlled commissioningRestore the accepted project and validate machine functions after any processor change.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Confirm the complete item, installed arrangement and controlled acceptance results before normal operation.
Need help matching PM583-ETH-XC to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact