PM595-4ETH-F — controller CPU

PM595-4ETH-F is an ABB AC500 controller CPU with 16384 kB of program memory and integrated 4 GB user flash storage. It combines two independent Ethernet interfaces with two Ethernet-based fieldbus interfaces, each incorporating a two-port switch.

ABBAC500controller CPU
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
PM595-4ETH-F product profile
Product familyAC500
Exact modelPM595-4ETH-F
Program memory16384 kB
Independent EthernetTwo interfaces
Fieldbus EthernetTwo interfaces, two-port switch each
Serial interfacesTwo configurable RS232/RS485
  • Brand:

    ABB
  • Item NO.:

    PM595-4ETH-F
  • Part Number:

  • Weight:

  • Dimensions:

  • Manufacture Year:

  • Place of Origin:

  • Certification:

  • Description:

PM595-4ETH-F configuration inquiry

Get a precise quote for PM595-4ETH-F

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

PM595-4ETH-F functions and installation

PM595-4ETH-F is an ABB AC500 controller CPU with 16384 kB of program memory and integrated 4 GB user flash storage. It combines two independent Ethernet interfaces with two Ethernet-based fieldbus interfaces, each incorporating a two-port switch. Executes the engineered application using the specified program and user-data resources. Provides the switched Ethernet-based fieldbus interfaces for the accepted protocol configuration.

Control processingExecutes the engineered application using the specified program and user-data resources.
Fieldbus connectivityProvides the switched Ethernet-based fieldbus interfaces for the accepted protocol configuration.
Network servicesKeep the two independent Ethernet connections distinct from the fieldbus switch ports.
Expansion planningReview the approved limit and actual configuration of added communication modules before a change.

Installation and selection boundaries

  • Supply voltage: 24 VDC.
  • Additional communication modules: Up to two, in the approved arrangement.
  • Validate the restored program, network paths and required process functions before release.
Official product data

PM595-4ETH-F key specifications

Supply voltage 24 VDC
User program memory 16384 kB
Integrated user data memory 16384 kB; 3072 kB saved
User flashdisk 4 GB, non-removable
Independent Ethernet Two interfaces
Ethernet-based fieldbus Two interfaces with a two-port switch each; four RJ45 fieldbus connections
Serial interfaces Two configurable RS232/RS485
Additional communication modules Up to two, in the approved arrangement

Source: ABB PLC Automation main catalogue, 3ADR020077C0204 Rev B, ordering data and technical tables, PDF pages 87,99.

Pre-order check 01

Installation environment

Prepare the installation and controlled change plan for PM595-4ETH-F.

  • Check the approved CPU/base combination, cabinet mounting, ventilation and access to the actual connectors.
  • Make affected circuits safe and verify the specified DC supply, polarity and protective-earth arrangement before connecting.
  • Retain a controlled project backup and record network addresses, serial settings and installed expansion hardware.
  • Restore the approved application in a safe state, inspect diagnostics and verify the required I/O and communication functions.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Application target
Match the actual processor revision, supported engineering target and approved application.
Network topology
Separate the two independent Ethernet interfaces from the two switched fieldbus interfaces.
Protocol setup
Confirm the protocol loaded and configured for each fieldbus interface in the actual project.
Communication expansion
Respect the limit of up to two additional communication modules in the specified arrangement.
Operational verification
Validate the restored program, network paths and required process functions before release.
Confirm the complete item, installed arrangement and controlled acceptance results before normal operation.
Recommended model families

More ABB models

ABBABB PM5072-R-ETHABB IM60ABB SDCS-UCM-1-COAT 3ADT220090R0008

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB IIMKM02AABB DO525ABB CM576-PNIO

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB DI525ABB V18345-1010261001ABB 3HAC061275-001

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB PM5132-T-ETHABB PM5112-R-ETHABB PM5072-T-ETH

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

Bently NevadaBently Nevada 330130-075-01-00Bently Nevada 330104-00-08-15-02-00Bently Nevada 330102-00-12-10-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330103-02-04-10-02-CNBently Nevada 330103-02-08-10-02-CNBently Nevada 330905-00-25-05-02-CN

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330903-00-07-10-01-CNBently Nevada 330903-00-07-10-01-00Bently Nevada 330876-03-10-00-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330906-02-12-10-02-05Bently Nevada 330902-00-95-05-02-05Bently Nevada 330876-01-50-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330851-01-000-020-10-00-00Bently Nevada 330879-03-00Bently Nevada 330851-02-000-040-10-00-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330180-X1-05 MOD 145004-75Bently Nevada 330851-02-000-080-90-01-05Bently Nevada 24701-28-05-XX-014-04-XX MOD 323933-40-02

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 24701-28-05-XX-025-04-XX MOD 323933-30-02Bently Nevada 129716-XXX-040-15 MOD 166797-0133Bently Nevada 24701-28-05-XX-104-03-XX MOD 323933-00-02

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES7143-5BF00-0BA0Siemens 6ES7144-5KD00-0BA0Siemens 6ES7144-4PF00-0AB0

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

PM595-4ETH-F Order Guide

Check the complete requested item against the actual installation before ordering.
1Record the identityKeep PM595-4ETH-F and the supplied revision on the maintenance record.
2Check the systemMatch the actual processor revision, supported engineering target and approved application.
3Prepare the mountingCheck the approved CPU/base combination, cabinet mounting, ventilation and access to the actual connectors.
4Plan the connectionsMake affected circuits safe and verify the specified DC supply, polarity and protective-earth arrangement before connecting.
5Control the changeRetain a controlled project backup and record network addresses, serial settings and installed expansion hardware.
6Verify operationRestore the approved application in a safe state, inspect diagnostics and verify the required I/O and communication functions.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
HoneywellMEL-BSSRT

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMEL-BSSRT-CC

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-AH04A

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-DC04C

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-DV04A

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-DV04C

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for PM595-4ETH-F selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

PM595-4ETH-F FAQ

How should the Ethernet connections on PM595-4ETH-F be counted?There are two independent Ethernet interfaces and two additional Ethernet-based fieldbus interfaces. Each fieldbus interface has a two-port switch, giving four fieldbus RJ45 connections; switch ports are not four independent fieldbus interfaces.
What user-program capacity is specified for PM595-4ETH-F?The technical table specifies 16384 kB of program memory. Keep that executable-memory allocation separate from the similarly sized user-data memory and the integrated flashdisk.
Which storage is available for PM595-4ETH-F application files?The processor includes a 4 GB non-removable user flashdisk for the appropriate application data-storage arrangement. File storage does not replace a controlled backup of the engineering project or retained control values.
Can both fieldbus switch ports on PM595-4ETH-F be treated as unrelated networks?The two ports belonging to one fieldbus interface form its integrated switch arrangement. Follow the engineered topology and protocol configuration instead of assigning each port an unrelated interface identity.
Does PM595-4ETH-F automatically support every Ethernet-based protocol at once?Protocol operation depends on the software and configuration applied to the relevant interface. Confirm the required protocol and its actual project setup rather than assuming that an RJ45 connector establishes a particular fieldbus function.
How many extra communication modules can be added to PM595-4ETH-F?The ordering information allows up to two additional communication modules in the applicable arrangement. Confirm the selected module combination and project support before expanding the station.
What serial electrical options are provided by PM595-4ETH-F?It provides two configurable RS232/RS485 serial interfaces. Set the correct mode and verify the actual terminal allocation, cabling and partner-device settings before communication is enabled.
How is saved user data distinguished on PM595-4ETH-F?The integrated user-data allocation is 16384 kB, with 3072 kB identified as saved. Review the application's retention needs and restore procedure separately from program loading and file-storage recovery.
What needs to be checked on the PM595-4ETH-F supply before startup?Verify the prescribed 24 VDC supply, polarity and the installation's grounding and protection arrangements. Evaluate the complete CPU and expansion assembly rather than treating the input-voltage value as a station current budget.
What tests are appropriate after a PM595-4ETH-F communication reconfiguration?Test the intended independent network paths, each configured fieldbus function and the application's required data exchange. Complete the checks in a controlled machine state and retain the accepted topology and configuration record.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
ABB AC500

Applications & Why Choose Nordwel

Application and maintenance planning for PM595-4ETH-F in the correctly matched installation.

Application areas

01Control processingExecutes the engineered application using the specified program and user-data resources.
02Fieldbus connectivityProvides the switched Ethernet-based fieldbus interfaces for the accepted protocol configuration.
03Network servicesKeep the two independent Ethernet connections distinct from the fieldbus switch ports.
04Expansion planningReview the approved limit and actual configuration of added communication modules before a change.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Confirm the complete item, installed arrangement and controlled acceptance results before normal operation.
Need help matching PM595-4ETH-F to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp