21500-00-28-10-02 — 5 mm standard-mount proximity probe

21500-00-28-10-02 is a Bently Nevada 7200-family 5 mm standard-mount proximity probe with a 2.8-inch case and 1.0-metre total probe lead. Use the complete probe, extension-cable and conditioner selection for the installed measuring chain.

Bently Nevada7200 proximity transducers5 mm standard-mount proximity probe
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
21500-00-28-10-02 product profile
Product family7200 proximity transducers
Exact model21500-00-28-10-02
Probe tip diameter5 mm
Case thread1/4-28
Case length2.8 inches
Total probe lead1.0 metre
  • Brand:

    Bently Nevada
  • Item NO.:

    21500-00-28-10-02
  • Part Number:

  • Weight:

  • Dimensions:

  • Manufacture Year:

  • Place of Origin:

  • Certification:

  • Description:

21500-00-28-10-02 configuration inquiry

Get a precise quote for 21500-00-28-10-02

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

21500-00-28-10-02 functions and installation

21500-00-28-10-02 is a Bently Nevada 7200-family 5 mm standard-mount proximity probe with a 2.8-inch case and 1.0-metre total probe lead. Use the complete probe, extension-cable and conditioner selection for the installed measuring chain. Supports noncontact static displacement measurement in the matched proximity-transducer system. The correctly matched chain can support the required vibration-related displacement measurement.

Shaft positionSupports noncontact static displacement measurement in the matched proximity-transducer system.
Dynamic displacementThe correctly matched chain can support the required vibration-related displacement measurement.
Mechanical selectionCompare the 1/4-28 mounting thread, case length and target access with the approved machine arrangement.
Installed-chain verificationPreserve the required total system length, conditioner selection and controlled gap verification.

Installation and selection boundaries

  • Probe tip diameter: 5 mm.
  • Tip construction: Fiberglass.
  • Check target material, gap and the required measurement response as one installed system.
Official product data

21500-00-28-10-02 key specifications

Probe tip diameter 5 mm
Mounting and thread Standard mount; 1/4-28
Unthreaded length 0.0 inches
Overall case length 2.8 inches
Total probe lead length 1.0 metre
Lead armor None
Connector Miniature male coaxial connector
Tip construction Fiberglass

Source: Bently Nevada L5001 (04/90), 7200 Proximity Transducer Systems, standard-mount ordering fields and construction table; original pages preserved in NASA report 19960001274, PDF pages 106-109.

Pre-order check 01

Installation environment

Prepare the installation and controlled change plan for 21500-00-28-10-02.

  • Confirm the 1/4-28 mounting, 2.8-inch case and required target clearance against the approved mechanical drawing.
  • Support the unarmored lead and protect the miniature coaxial connector from damage and contamination.
  • Select the extension cable and conditioner for the accepted total system arrangement, keeping every complete item marking.
  • Set the intended gap and verify the system output and required shaft measurement before normal machine operation.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Probe construction
Match the 5 mm standard-mount probe construction and the complete supplied ordering code.
Mechanical dimensions
Check 0.0-inch unthreaded length and 2.8-inch overall case length against the actual mounting.
Lead and connector
Retain the 1.0-metre probe lead and intended miniature male coaxial connection.
Transducer chain
Confirm the appropriate extension cable and conditioner for the approved system length.
Calibration
Check target material, gap and the required measurement response as one installed system.
Confirm the complete item, installed arrangement and controlled acceptance results before normal operation.
Recommended model families

More Bently Nevada models

Bently NevadaBently Nevada 330903-00-07-10-01-CNBently Nevada 330903-00-07-10-01-00Bently Nevada 330876-03-10-00-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330906-02-12-10-02-05Bently Nevada 330902-00-95-05-02-05Bently Nevada 330876-01-50-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330851-01-000-020-10-00-00Bently Nevada 330879-03-00Bently Nevada 330851-02-000-040-10-00-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330180-X1-05 MOD 145004-75Bently Nevada 330851-02-000-080-90-01-05Bently Nevada 24701-28-05-XX-014-04-XX MOD 323933-40-02

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

SiemensSiemens 6ES5948-3UA13Siemens 6ES5945-7UA23Siemens 6ES5941-7UA12

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES5921-3WB12Siemens 6ES5541-8AA11Siemens 6ES5470-4UC13

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES5465-4UA13Siemens 6ES5464-8MF21Siemens 6ES5464-8ME11

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600BF830General Electric IC600BF908General Electric IC600BF914

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600BF915General Electric IC600BF923General Electric IC600BF940

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600BF941General Electric IC600BF942General Electric IC600BF948

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600CB504General Electric IC600CB507General Electric IC600CB513

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600CB516General Electric IC600CB525General Electric IC600CB536

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

21500-00-28-10-02 Order Guide

Check the complete requested item against the actual installation before ordering.
1Record the identityKeep 21500-00-28-10-02 and the supplied revision on the maintenance record.
2Check the systemMatch the 5 mm standard-mount probe construction and the complete supplied ordering code.
3Prepare the mountingConfirm the 1/4-28 mounting, 2.8-inch case and required target clearance against the approved mechanical drawing.
4Plan the connectionsSupport the unarmored lead and protect the miniature coaxial connector from damage and contamination.
5Control the changeSelect the extension cable and conditioner for the accepted total system arrangement, keeping every complete item marking.
6Verify operationSet the intended gap and verify the system output and required shaft measurement before normal machine operation.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
HoneywellMEL-BSSRT

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMEL-BSSRT-CC

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-AH04A

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-DC04C

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-DV04A

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-DV04C

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for 21500-00-28-10-02 selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

21500-00-28-10-02 FAQ

What does the 5 mm designation mean for 21500-00-28-10-02?It is the probe-tip diameter, not the case length or measuring range. Match the tip construction and the required target access to the approved machine installation.
How do the case dimensions of 21500-00-28-10-02 affect mounting?The ordering fields specify 0.0 inches of unthreaded length and a 2.8-inch overall case. Compare those dimensions with the housing and available adjustment travel before accepting the fit.
Is the 1.0-metre dimension on 21500-00-28-10-02 an extension-cable length?It is the total probe lead length associated with this probe configuration. Any separate extension cable must be selected as part of the approved combined system rather than counted as part of the mechanical case.
Which connector is specified for 21500-00-28-10-02?The connector option identifies a miniature male coaxial connector. Check the actual mating connector, cleanliness and retention before joining the measuring chain.
How should the unarmored 21500-00-28-10-02 lead be routed?Support the lead and protect it from sharp edges, vibration-related chafing and mechanical loads at the probe junction. Leave appropriate service access without changing the required electrical system configuration.
Can 21500-00-28-10-02 measure both static position and changing displacement?The correctly matched 7200 measuring chain can measure static and dynamic distance between the probe tip and a conductive target. Establish the required monitor and application setup for the intended machine measurement.
What does the fiberglass tip construction of 21500-00-28-10-02 imply for inspection?Inspect the sensing tip for cracks, contamination or physical damage and compare its condition with the accepted maintenance criteria. The material description is not permission to use a damaged tip or force the probe against the target.
Can 21500-00-28-10-02 be connected directly as a conventional DC-powered sensor?No. It works with the appropriate proximity signal conditioner and cable arrangement. Connect and power the conditioner according to its own terminal instructions rather than applying a transmitter supply to the probe lead.
Why must the system arrangement be checked when 21500-00-28-10-02 is replaced?The probe lead, any extension cable and the conditioner form the measuring chain. Preserve the approved combined length and matching arrangement so that a mechanically fitting probe does not introduce an incorrect electrical configuration.
How is the final gap setting of 21500-00-28-10-02 established?Use the applicable installed-system procedure and verify the required output with the actual target. A nominal family measuring range is not a universal mounting gap, so record the accepted setting and functional result for the machine.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
Bently Nevada 7200 proximity transducers

Applications & Why Choose Nordwel

Application and maintenance planning for 21500-00-28-10-02 in the correctly matched installation.

Application areas

01Shaft positionSupports noncontact static displacement measurement in the matched proximity-transducer system.
02Dynamic displacementThe correctly matched chain can support the required vibration-related displacement measurement.
03Mechanical selectionCompare the 1/4-28 mounting thread, case length and target access with the approved machine arrangement.
04Installed-chain verificationPreserve the required total system length, conditioner selection and controlled gap verification.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Confirm the complete item, installed arrangement and controlled acceptance results before normal operation.
Need help matching 21500-00-28-10-02 to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp