6ES7215-1BG31-0XB0 — dual-port AC/DC/relay compact controller

Adds two PROFINET ports and integrated analog output capability to local machine control. The CPU combines digital and analog I/O with 100 KB of program/data memory.

SiemensS7-1200 / CPU 1215Cdual-port AC/DC/relay compact controller
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
6ES7215-1BG31-0XB0 product profile
Product familyS7-1200 / CPU 1215C
Exact model6ES7215-1BG31-0XB0
PROFINET ports2
Digital I/O14 DC inputs; 10 relay outputs
Analog I/O2 voltage inputs; 2 current outputs
Program/data memory100 KB
  • Brand:

    SIEMENS
  • Item NO.:

    6ES7215-1BG31-0XB0
6ES7215-1BG31-0XB0 configuration inquiry

Get a precise quote for 6ES7215-1BG31-0XB0

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

6ES7215-1BG31-0XB0 functions and installation

Map the voltage inputs, current-command outputs and relay circuits separately in the wiring schedule. Record both network cable destinations and retain the accepted project configuration before replacing the CPU.

Application controlCoordinates the configured digital and analog control tasks.
Network connectionProvides two PROFINET ports.
Analog actuationSupplies integrated current-output channels.
Signal acquisitionCombines discrete inputs with voltage measurement inputs.

Installation and selection boundaries

  • Record both network cable destinations before removal.
  • Preserve the distinction between analog voltage inputs and analog current outputs.
  • Review the relay load circuits independently from analog signal wiring.
Official product data

6ES7215-1BG31-0XB0 key specifications

Controller CPU 1215C
Execution AC/DC/relay
PROFINET ports 2
Digital inputs 14 at 24 V DC
Digital outputs 10 relay outputs, 2 A
Analog inputs 2, 0–10 V DC
Analog outputs 2, 0–20 mA DC
Program/data memory 100 KB

Siemens exact-product catalogue and applicable S7 installation information.

Pre-order check 01

Installation environment

Use the installation drawing for the actual equipment and complete these checks before return to service.

  • Shut down and isolate the CPU and all connected field circuits under the site procedure.
  • Identify both network cable destinations and retain the accepted network settings.
  • Label the voltage-input and current-output wiring before disconnecting terminals.
  • Check the restored program and verify analog output commands with the process secured.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Controller execution
Match CPU 1215C AC/DC/relay and the complete requested item.
Analog circuit type
Keep 0–10 V inputs distinct from 0–20 mA outputs.
Network arrangement
Compare both physical port connections and the project network configuration.
Program resources
Confirm the application fits the listed integrated memory.
Actuator circuits
Review relay load protection and current-output scaling before operation.
Keep network configuration, analog circuit type and relay-load suitability in the replacement review.
Recommended model families

More Siemens models

SiemensSiemens 6GK1143-0AA01Siemens 6ES5470-4UC13Siemens 6ES5464-8ME11

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES5464-8MF21Siemens 6GK5308-2FM10-2AA3Siemens 6ES7144-4FF01-0AB0

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6GK1143-0TA02Siemens 6ES7144-1GB31-0XB0Siemens 6ES5921-3WB12

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES7144-4PF00-0AB0Siemens 6ES5465-4UA13Siemens 6ES5951-7LB21

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

Siemens / Bently NevadaSiemens 6ES5541-8AA11Bently Nevada 330103-02-04-10-02-CNBently Nevada 330102-00-12-10-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

ABB / SiemensABB PM5112-R-ETHSiemens 6ES5948-3UA23Siemens 6ES7144-5KD00-0BA0

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently Nevada / SiemensBently Nevada 330104-00-08-15-02-00Siemens 6ES5948-3UA13Bently Nevada 330851-01-000-020-10-00-00

Separate product references; inclusion does not establish compatibility or interchangeability.

ABB / Bently Nevada / SiemensABB 3HAC061275-001Bently Nevada 330903-00-07-10-01-00Siemens 6ES7143-5BF00-0BA0

Separate product references; inclusion does not establish compatibility or interchangeability.

Siemens / Bently NevadaSiemens 6ES7143-5AH00-0BA0Bently Nevada 330906-02-12-10-02-05Bently Nevada 330876-03-10-00-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently Nevada / ABB / SiemensBently Nevada 330902-00-95-05-02-05ABB IM60Siemens 6ES5945-7UA23

Separate product references; inclusion does not establish compatibility or interchangeability.

Siemens / Bently Nevada / ABBSiemens 6ES5941-7UA12Bently Nevada 330854-080-25-05ABB PM5072-R-ETH

Separate product references; inclusion does not establish compatibility or interchangeability.

Siemens / ABBSiemens 6ES7144-1JB31-0XB0ABB PM5072-T-ETHSiemens 6ES7143-4BF50-0AA0

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

6ES7215-1BG31-0XB0 Order Guide

Check the complete requested item against the actual installation before ordering.
1Confirm the itemRecord 6ES7215-1BG31-0XB0 exactly as requested and compare the delivered nameplate.
2Describe the installationProvide the host equipment, existing connections and required supplied scope.
3Review the applicationMatch CPU 1215C AC/DC/relay and the complete requested item.
4Check the electrical interfaceKeep 0–10 V inputs distinct from 0–20 mA outputs.
5Plan the replacementShut down and isolate the CPU and all connected field circuits under the site procedure.
6Accept the assemblyKeep network configuration, analog circuit type and relay-load suitability in the replacement review.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
Siemens6ES7144-4JF00-0AB0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7142-6BH00-0AB0

A separate product reference; verify its own installation and configuration.

Specialist model
Bently Nevada330854-080-24-05

A separate product reference; verify its own installation and configuration.

Specialist model
Bently Nevada330130-070-01-00

A separate product reference; verify its own installation and configuration.

Specialist model
Bently Nevada330130-075-01-00

A separate product reference; verify its own installation and configuration.

Specialist model
Bently Nevada330103-02-08-10-02-CN

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for 6ES7215-1BG31-0XB0 selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

6ES7215-1BG31-0XB0 FAQ

How many PROFINET ports are integrated in 6ES7215-1BG31-0XB0?Two PROFINET ports are integrated. Record the actual cable arrangement and project network settings before changing the CPU.
Does this CPU provide analog outputs as well as analog inputs?Yes. It provides two 0–10 V DC analog inputs and two 0–20 mA DC analog outputs. Keep the input and output circuit types distinct during wiring checks.
Can an actuator expecting a voltage command use a built-in current output unchanged?No. The integrated analog outputs are current outputs. The actuator input and any required conversion interface must match the selected signal and scaling.
What is the integrated memory figure for this CPU 1215C execution?The program/data memory is listed as 100 KB. Check the application resource requirements and actual project configuration before transfer.
Are the ten digital outputs semiconductor switching outputs?No. This AC/DC/relay execution provides ten relay outputs. Their switching application must be reviewed as relay-contact circuits.
What must be preserved when reconnecting the two network cables?Retain cable identification, the intended connected devices and the network configuration. Two available ports do not make an arbitrary network reconnection acceptable.
Which onboard signals should be included in the initial I/O test?Test the 14 digital inputs, the relay output commands and the analog input/output channels used by the application. Keep unused channels identified rather than assuming their wiring is correct.
Can the CPU be substituted on the basis of the 1215C designation alone?No. The full item code, electrical execution, firmware and configured devices must agree with the installation. A shared designation does not prove a drop-in replacement.
How should current-output scaling be checked after a CPU replacement?Compare the application command, the current measured in the properly connected loop and the actuator response. Verify the configured process range before permitting automatic control.
What should be reviewed before the first automatic cycle with 6ES7215-1BG31-0XB0?Complete the wiring, network and project checks, then validate the required interlocks and actuator behavior in a controlled test. The machine should remain secured until the acceptance checks pass.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
Siemens S7-1200 / CPU 1215C

Applications & Why Choose Nordwel

Application and maintenance planning for 6ES7215-1BG31-0XB0 in the correctly matched installation.

Application areas

01Networked machine controlCombines a dual-port network connection with local I/O.
02Current-command actuationProvides integrated current outputs for a suitably matched actuator interface.
03Mixed-signal cabinetsBrings discrete signals and analog measurements into one compact CPU.
04Planned system maintenanceRequires coordinated restoration of the program, network and signal scaling.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Keep network configuration, analog circuit type and relay-load suitability in the replacement review.
Need help matching 6ES7215-1BG31-0XB0 to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
Control, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
Control, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
Control, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
Control, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
Control, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
Control, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
Control, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
Control, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp