other
Products
Vibro-Meter MPC4 Mk2 machinery protection and monitoring processor product views
Vibro-Meter MPC4 Mk2 machinery protection and monitoring processor product views
Vibro-Meter MPC4 Mk2 machinery protection and monitoring processor product views

Vibro-Meter MPC4 Mk2 machinery protection and monitoring processor

EMAIL SALES
Vibro-Meter VM600 Mk2
MPC4 Mk2 — machinery protection and monitoring processor

MPC4 Mk2 is offered for matched VM600 Mk2 installations. Processes the configured machinery-protection and monitoring signals in the matched module.

Vibro-MeterVM600 Mk2machinery protection and monitoring pr
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
MPC4 Mk2 product profile
Product familyVM600 Mk2
Exact modelMPC4 Mk2
Dynamic inputs4 channels in the matched module
Auxiliary inputs2 channels in the matched module
Hardware positionFront processing portion
Software conditionCondition monitoring licence dependent
  • Brand:

    Others
  • Item NO.:

    MPC4 Mk2
MPC4 Mk2 configuration inquiry

Get a precise quote for MPC4 Mk2

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

MPC4 Mk2 functions and installation

Processes the configured machinery-protection and monitoring signals in the matched module. Use the approved paired rear input/output hardware. Specify front processor, rear interface and software/configuration scope independently.

Application purposeProcesses the configured machinery-protection and monitoring signals in the matched module.
Connection arrangementUse the approved paired rear input/output hardware.
Installation preparationPreserve sensor assignments, alarm settings and the configuration backup.
Operational acceptanceProve configured measurements, alarms and outputs before protection is released.

Installation and selection boundaries

  • Retain sensor types and assignments for the four dynamic and two auxiliary channels.
  • Restore the accepted alarm and output configuration.
  • Agree condition-monitoring licensing separately from default protection functionality.
Official product data

MPC4 Mk2 key specifications

Platform VM600 Mk2
Hardware role Front machinery-monitoring processor
Dynamic channels 4 in the matched module
Auxiliary channels 2 in the matched module
Protection function Machinery protection
Condition monitoring Optional, dependent on purchased software licence

Vibro-Meter VM600 product and system documentation.

Pre-order check 01

Installation environment

Prepare MPC4 Mk2 against the accepted equipment drawing and maintenance procedure.

  • Place machinery protection under the approved maintenance and process controls.
  • Preserve sensor assignments, alarm settings and the configuration backup.
  • Inspect front-module contacts and the matching rear-interface arrangement.
  • Prove configured measurements, alarms and outputs before protection is released.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Rear interface
Use the approved paired rear input/output hardware.
Measurement configuration
Retain sensor types and assignments for the four dynamic and two auxiliary channels.
Protection settings
Restore the accepted alarm and output configuration.
Software entitlement
Agree condition-monitoring licensing separately from default protection functionality.
Supplied module
Specify front processor, rear interface and software/configuration scope independently.
Specify front processor, rear interface and software/configuration scope independently.
Recommended model families

More Vibro-Meter models

Vibro-MeterVibro-Meter S3960 AC46286 144-201-000-222Vibro-Meter TQ402 111-402-000-012 A1-B1-D000-E010-F0-G000-H05Vibro-Meter TQ402 111-402-000-012

Separate product references; inclusion does not establish compatibility or interchangeability.

Vibro-MeterVibro-Meter AF70982 111-412-000-012Vibro-Meter TQ402 111-402-000-013 S3960 A1-B1-C042-D000-E010-F0-G000Vibro-Meter CA134 144-134-000-612

Separate product references; inclusion does not establish compatibility or interchangeability.

Vibro-MeterVibro-Meter CA202 144-202-000-215Vibro-Meter CA202 144-202-000-205Vibro-Meter TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

Siemens / General ElectricSiemens 6ES7143-5AH00-0BA0General Electric IC600BF948General Electric IC600BF942

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently Nevada / General ElectricBently Nevada 330103-02-08-10-02-CNGeneral Electric IC600BF923General Electric IC600CB513

Separate product references; inclusion does not establish compatibility or interchangeability.

General Electric / Bently NevadaGeneral Electric IC600BF908Bently Nevada 330905-00-25-05-02-CNBently Nevada 330102-00-12-10-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

General Electric / Bently Nevada / SiemensGeneral Electric IC600BF941Bently Nevada 330130-075-01-00Siemens 6ES7144-4FF01-0AB0

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently Nevada / SiemensBently Nevada 330876-03-10-00-00Bently Nevada 330103-02-04-10-02-CNSiemens 6ES7144-4JF00-0AB0

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently Nevada / General ElectricBently Nevada 330130-070-01-00General Electric IC600BF940General Electric IC600BF914

Separate product references; inclusion does not establish compatibility or interchangeability.

Siemens / General ElectricSiemens 6GK1143-0TA02Siemens 6ES7142-6BH00-0AB0General Electric IC600BF915

Separate product references; inclusion does not establish compatibility or interchangeability.

General Electric / SiemensGeneral Electric IC600CB507Siemens 6ES7143-5BF00-0BA0Siemens 6ES7144-4PF00-0AB0

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

MPC4 Mk2 Order Guide

Check the complete requested item against the actual installation before ordering.
1Retain the full identityRecord MPC4 Mk2 with its complete hardware identification.
2Review the assemblyUse the approved paired rear input/output hardware.
3Capture the operating configurationRetain sensor types and assignments for the four dynamic and two auxiliary channels.
4Inspect the installationInspect front-module contacts and the matching rear-interface arrangement.
5Define the order scopeSpecify front processor, rear interface and software/configuration scope independently.
6Prove the restored functionProve configured measurements, alarms and outputs before protection is released.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
Siemens6ES7144-5KD00-0BA0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-1JB31-0XB0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-1GB31-0XB0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6GK5308-2FM10-2AA3

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7143-4BF50-0AA0

A separate product reference; verify its own installation and configuration.

Specialist model
General ElectricIC600BF830

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for MPC4 Mk2 selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

MPC4 Mk2 FAQ

How many dynamic channels are defined for MPC4 Mk2's matched module?The matched module has four dynamic channels. Preserve each configured sensor and measurement assignment when planning replacement.
What is the auxiliary-channel count of the machinery-monitoring module?The matched module provides two auxiliary channels. Check their actual configured use rather than treating them as additional dynamic channels.
Is the front processor delivered with its rear field interface automatically?The supplied scope must distinguish the front processor and rear input/output hardware. A photograph of a pair does not define a processor-only order.
Does machinery-protection functionality depend on buying the CMS licence?Machinery protection is the default function described for the module. Optional condition monitoring has its own purchased software-licence condition.
Can all monitoring capabilities be assumed active immediately after hardware replacement?Restore the accepted configuration and purchased software scope. Hardware presence alone does not establish every optional function.
What signal information should be preserved before the front module is changed?Preserve sensor types, measurement assignments, alarm settings and the matching rear-interface identity with the configuration backup.
How should a standard versus safety module be chosen?Match the complete required configuration and its system acceptance requirements. The general type name is not a substitute for the selected variant.
What should receiving inspection confirm on MPC4 Mk2?Check complete hardware/configuration identification, connector condition and the agreed front-module scope before fitting it into the rack.
Which test should precede returning machinery protection to service?Prove required measurements, configured alarm behaviour and associated outputs under the accepted controlled commissioning procedure.
What records should remain after a processor replacement?Retain the fitted identity, configuration version, software entitlement scope and completed protection/monitoring acceptance results.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
Vibro-Meter VM600 Mk2

Applications & Why Choose Nordwel

Application and maintenance planning for MPC4 Mk2 in the correctly matched installation.

Application areas

01Machinery protectionProcess the configured monitoring signals in the approved module arrangement.
02Condition-monitoring projectsApply the separately purchased software scope and configuration.
03Processor replacementPreserve sensor and alarm settings during a controlled outage.
04Protection acceptanceVerify the required signal, alarm and output responses.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Specify front processor, rear interface and software/configuration scope independently.
Need help matching MPC4 Mk2 to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp