ICMK-CS31-A1.0 1SBP260057R1001 — 120/230 V AC remote replacement unit

ICMK-CS31-A1.0 1SBP260057R1001 is a CS31 remote replacement unit with a 120/230 V AC power supply. Its eight isolated 24 V DC inputs select the replacement configuration; field I/O is provided through the correctly selected extensions rather than assumed from the housing markings.

ABBAC31 / CS31CS31 remote replacement unit
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
ICMK-CS31-A1.0 1SBP260057R1001 product profile
Product familyAC31 / CS31
Exact modelICMK-CS31-A1.0 1SBP260057R1001
Supply version120/230 V AC
Configuration inputs8 isolated, nominal 24 V DC
System busCS31 over RS485
Dimensions W × H × D120 × 93 × 84 mm
  • Brand:

    ABB
  • Item NO.:

    ICMK-CS31-A1.0 1SBP2
ICMK-CS31-A1.0 1SBP260057R1001 configuration inquiry

Get a precise quote for ICMK-CS31-A1.0 1SBP260057R1001

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

ICMK-CS31-A1.0 1SBP260057R1001 functions and installation

The ICMK-CS31-A1.0 1SBP260057R1001 unit supports controlled replacement of legacy remote stations on the CS31 system bus. Compatibility depends on the original remote function, central unit, addressing and extension arrangement; it is not an unrestricted drop-in replacement for every station.

Legacy station replacementAdapts the supported remote-station behavior to a configured AC31 extension arrangement.
CS31 communicationUses the established serial bus and the replacement station address.
Hardware configurationUses the isolated inputs to select the required signal format and replacement mode.
Extension connectionProvides the remote-unit interface for separately chosen I/O extensions.

Installation and selection boundaries

  • The incorporated inputs configure the remote unit; they must not be advertised as eight unrestricted process inputs.
  • The remote unit has no available onboard process outputs, even if a shared housing has output indicators.
  • Replacement can require new wiring and additional panel space; central-unit and remote-function restrictions still apply.
Official product data

ICMK-CS31-A1.0 1SBP260057R1001 key specifications

Nominal mains supply 120/230 V AC, 50/60 Hz
Permitted mains ranges 97.75–126.5 V AC or 195.5–253 V AC
Configuration inputs 8 isolated inputs, nominal 24 V DC; PNP and NPN types
Input logic levels State 0: 0–5 V; state 1: 15–30 V
System-bus interface RS485, shielded twisted-pair CS31 bus
Onboard process outputs None; select the required separate I/O extensions
Isolated input-supply output 19.2–30 V DC, maximum 400 mA, short-circuit protected
Operating ambient Horizontal mounting: 0–55 °C; vertical mounting: 0–40 °C
Dimensions W × H × D 120 × 93 × 84 mm

ABB AC31 technical documentation, Chapter 20: ICMK-CS31 remote unit, 1SBC121001M0201-b, February 2007, sections 1.1–1.5; exact ordering reference in section 1.3.

Pre-order check 01

Installation environment

Prepare a controlled installation of ICMK-CS31-A1.0 1SBP260057R1001 using the accepted circuit and commissioning records.

  • Isolate the mains and field circuits; record the original bus address, base switches, conductor labels and remote function before removal.
  • Verify the AC supply version and the L, N and protective-earth connections against the accepted circuit drawing.
  • Select the documented extensions and configuration-input states for the particular remote function; leave reserved inputs unused.
  • Check bus polarity, shield and end termination, then carry out the controlled I/O and diagnostic acceptance checks before handover.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Complete item
Match ICMK-CS31-A1.0 1SBP260057R1001 and the actual identification marks; do not infer an undocumented suffix meaning.
Power version
Use the 120/230 V AC circuit and its permitted voltage range, not the wiring of a DC-powered variant.
Original application
Check the legacy station function, central-unit type and each replacement restriction before selecting extensions.
Bus and address
Retain the required CS31 address, BUS1/BUS2 continuity and the approved shield and termination arrangement.
Cabinet and wiring
Allow for the unit plus extensions, orientation-dependent temperature limits and the changed conductor layout.
Check the supported replacement case, AC supply, configuration-input states, extensions and CS31 address together. Match the complete nameplate identity and revision to the installed unit before reconnection.
Recommended model families

More ABB models

ABBABB 3HAC061275-001ABB PM5132-T-ETHABB PM5112-R-ETH

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB PM5072-T-ETHABB PM5072-R-ETHABB IM60

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB SDCS-UCM-1-COAT 3ADT220090R0008ABB IIMKM02AABB DO525

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB CM576-PNIOABB DI525ABB V18345-1010261001

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

HoneywellHoneywell MLF-AH04AHoneywell MLF-DC04CHoneywell MLF-DV04A

Separate product references; inclusion does not establish compatibility or interchangeability.

HoneywellHoneywell MLF-DV04CHoneywell MLF-HD02AHoneywell MLF-PD02A

Separate product references; inclusion does not establish compatibility or interchangeability.

HoneywellHoneywell MLF-RD04AHoneywell MLF-TC04SHoneywell MLI-DN10E

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600BF830General Electric IC600BF908General Electric IC600BF914

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600BF915General Electric IC600BF923General Electric IC600BF940

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600BF941General Electric IC600BF942General Electric IC600BF948

Separate product references; inclusion does not establish compatibility or interchangeability.

General ElectricGeneral Electric IC600CB504General Electric IC600CB507General Electric IC600CB513

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES7143-5BF00-0BA0Siemens 6ES7144-5KD00-0BA0Siemens 6ES7144-4PF00-0AB0

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

ICMK-CS31-A1.0 1SBP260057R1001 Order Guide

Check the complete requested item against the actual installation before ordering.
1Record the legacy stationKeep the original remote function, address, base switches and conductor identification before isolation.
2Match the complete new itemSpecify ICMK-CS31-A1.0 1SBP260057R1001 and confirm the AC-power identification on the delivered unit.
3Select the permitted replacementAssess the central unit, supported remote-function mapping and required extension arrangement.
4Plan panel changesAllow for the complete assembly dimensions and prepare the revised power, bus and field-wiring drawing.
5Agree the order scopeList the remote unit, separate I/O extensions and any required connection hardware explicitly.
6Complete controlled acceptanceCheck configuration, communication and field signals; retain the accepted settings for maintenance.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
HoneywellCC-ZHR041

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMEL-BSSRT

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMEL-BSSRT-CC

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-4JF00-0AB0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-4FF01-0AB0

A separate product reference; verify its own installation and configuration.

Specialist model
Siemens6ES7144-1JB31-0XB0

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for ICMK-CS31-A1.0 1SBP260057R1001 selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

ICMK-CS31-A1.0 1SBP260057R1001 FAQ

What is the role of ICMK-CS31-A1.0 1SBP260057R1001 in a CS31 installation?It is a remote replacement unit that connects an appropriately configured extension station to the CS31 bus. It is not the central processor, and the required process input and output functions depend on the selected extensions and supported replacement arrangement.
Which power supply belongs to ICMK-CS31-A1.0 1SBP260057R1001?The ordering reference is the 120/230 V AC version at 50/60 Hz. The documented ranges are 97.75–126.5 V AC for the lower nominal supply and 195.5–253 V AC for the higher one. Match the actual circuit before energizing.
Are the eight inputs on ICMK-CS31-A1.0 1SBP260057R1001 ordinary field inputs?They are isolated 24 V DC configuration inputs used to define the replacement format and operating mode. Their number must not be used to promise eight independent process channels; determine process I/O from the documented extension configuration.
Does ICMK-CS31-A1.0 1SBP260057R1001 have six usable relay outputs?No. The manufacturer states that this remote unit has no available onboard outputs. Housing indicators or a photograph of a different basic unit do not establish usable relay outputs or supplied process-I/O capacity.
Can ICMK-CS31-A1.0 1SBP260057R1001 replace every legacy remote without changes?No. Applicability depends on the original station function and central-unit type, and the replacement may require new wiring. Review the specific replacement restrictions and preserve the original configuration records before disconnecting the station.
How should the address of ICMK-CS31-A1.0 1SBP260057R1001 be selected?Use the CS31 address required for the remote station being replaced, after recording the original address and switch settings. Check the resulting configuration and communication during acceptance; a different physical unit must not create a duplicate bus address.
What are the bus-wiring requirements for ICMK-CS31-A1.0 1SBP260057R1001?The CS31 link uses shielded twisted-pair RS485 wiring. Preserve BUS1-to-BUS1 and BUS2-to-BUS2 continuity, connect the shield as specified, and retain the required 120-ohm termination at the bus ends rather than adding termination at every station.
Why does mounting orientation matter for ICMK-CS31-A1.0 1SBP260057R1001?The allowed operating ambient is 0–55 °C in the horizontal position and 0–40 °C vertically. Assess the actual cabinet temperature and complete station arrangement against the applicable orientation limit, not the higher value alone.
Can the isolated supply from ICMK-CS31-A1.0 1SBP260057R1001 feed any panel load?It is the documented supply for the input circuits, with a 19.2–30 V DC range and a maximum output of 400 mA. Keep its intended use and load limit separate from the mains rating; it is not an unrestricted auxiliary panel supply.
What should be preserved before installing ICMK-CS31-A1.0 1SBP260057R1001?Record the old remote function, address, base switches, any analogue-module settings and every conductor assignment. Also check the new unit-plus-extension dimensions, since a replacement station can require more space than the original assembly.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
ABB AC31 / CS31

Applications & Why Choose Nordwel

Application and maintenance planning for ICMK-CS31-A1.0 1SBP260057R1001 in the correctly matched installation.

Application areas

01CS31 remote-station renewalApply ICMK-CS31-A1.0 1SBP260057R1001 to a supported legacy station replacement with the documented extension and address arrangement.
02AC-powered remote panelsIntegrate the correct mains version while keeping the isolated configuration circuits distinct from the AC power terminals.
03Configured extension stationsUse the unit as the bus interface and hardware-configuration element for the selected process I/O extensions.
04Planned migration outagesRecord existing switches and field wiring, provide the required additional space, and validate the restored station before returning the process to service.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Check the supported replacement case, AC supply, configuration-input states, extensions and CS31 address together. Match the complete nameplate identity and revision to the installed unit before reconnection.
Need help matching ICMK-CS31-A1.0 1SBP260057R1001 to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp