PM592-ETH-XC — controller CPU

PM592-ETH-XC is an ABB AC500-XC controller CPU with a 4 GB integrated user flashdisk and 4096 kB of program memory. Program memory, user-data memory and file storage are separate resources in application planning.

ABBAC500-XCcontroller CPU
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
PM592-ETH-XC product profile
Product familyAC500-XC
Exact modelPM592-ETH-XC
Program memory4096 kB
User flashdisk4 GB, non-removable
Ethernet interfacesOne
DC supply24 VDC
  • Brand:

    ABB
  • Item NO.:

    PM592-ETH-XC
  • Part Number:

  • Weight:

  • Dimensions:

  • Manufacture Year:

  • Place of Origin:

  • Certification:

  • Description:

PM592-ETH-XC configuration inquiry

Get a precise quote for PM592-ETH-XC

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

PM592-ETH-XC functions and installation

PM592-ETH-XC is an ABB AC500-XC controller CPU with a 4 GB integrated user flashdisk and 4096 kB of program memory. Program memory, user-data memory and file storage are separate resources in application planning. Combines control-program execution with integrated user flash storage for the engineered application. Provides the single Ethernet interface used by the approved project and access arrangement.

Control and file storageCombines control-program execution with integrated user flash storage for the engineered application.
Network accessProvides the single Ethernet interface used by the approved project and access arrangement.
Serial-device integrationMatch the two configurable serial interfaces to the actual connected devices and wiring.
Service preparationBack up the application and required files and record the station before processor maintenance.

Installation and selection boundaries

  • Supply voltage: 24 VDC.
  • Data buffering: Battery.
  • Verify restored logic, required data and communication functions before normal process operation.
Official product data

PM592-ETH-XC key specifications

Supply voltage 24 VDC
User program memory 4096 kB
Integrated user data memory 5632 kB; 1536 kB saved
User flashdisk 4 GB, non-removable
Ethernet interface One
Serial interfaces Two configurable RS232/RS485
Operator display LC display and eight function keys
Data buffering Battery

Source: ABB PLC Automation main catalogue, 3ADR020077C0204 Rev B, ordering data and technical tables, PDF pages 134,146.

Pre-order check 01

Installation environment

Prepare the installation and controlled change plan for PM592-ETH-XC.

  • Check the approved CPU/base combination, cabinet mounting, ventilation and access to the actual connectors.
  • Make affected circuits safe and verify the specified DC supply, polarity and protective-earth arrangement before connecting.
  • Retain a controlled project backup and record network addresses, serial settings and installed expansion hardware.
  • Restore the approved application in a safe state, inspect diagnostics and verify the required I/O and communication functions.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Hardware scope
Match the complete AC500-XC CPU identity, base and installed expansion hardware.
Storage resource
Treat the 4 GB flashdisk as file storage, not additional control-program memory.
Retained values
Plan saved user data independently of file backup and program restoration.
Communication setup
Confirm Ethernet addressing and the selected RS232/RS485 interface modes.
Acceptance plan
Verify restored logic, required data and communication functions before normal process operation.
Confirm the complete item, installed arrangement and controlled acceptance results before normal operation.
Recommended model families

More ABB models

ABBABB PM5072-T-ETHABB PM5072-R-ETHABB IM60

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB SDCS-UCM-1-COAT 3ADT220090R0008ABB IIMKM02AABB DO525

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB CM576-PNIOABB DI525ABB V18345-1010261001

Separate product references; inclusion does not establish compatibility or interchangeability.

ABBABB 3HAC061275-001ABB PM5132-T-ETHABB PM5112-R-ETH

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

Bently NevadaBently Nevada 330854-080-25-05Bently Nevada 330854-080-24-05Bently Nevada 330130-070-01-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330130-075-01-00Bently Nevada 330104-00-08-15-02-00Bently Nevada 330102-00-12-10-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330103-02-04-10-02-CNBently Nevada 330103-02-08-10-02-CNBently Nevada 330905-00-25-05-02-CN

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330903-00-07-10-01-CNBently Nevada 330903-00-07-10-01-00Bently Nevada 330876-03-10-00-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330906-02-12-10-02-05Bently Nevada 330902-00-95-05-02-05Bently Nevada 330876-01-50-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330851-01-000-020-10-00-00Bently Nevada 330879-03-00Bently Nevada 330851-02-000-040-10-00-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330180-X1-05 MOD 145004-75Bently Nevada 330851-02-000-080-90-01-05Bently Nevada 24701-28-05-XX-014-04-XX MOD 323933-40-02

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 24701-28-05-XX-025-04-XX MOD 323933-30-02Bently Nevada 129716-XXX-040-15 MOD 166797-0133Bently Nevada 24701-28-05-XX-104-03-XX MOD 323933-00-02

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

PM592-ETH-XC Order Guide

Check the complete requested item against the actual installation before ordering.
1Record the identityKeep PM592-ETH-XC and the supplied revision on the maintenance record.
2Check the systemMatch the complete AC500-XC CPU identity, base and installed expansion hardware.
3Prepare the mountingCheck the approved CPU/base combination, cabinet mounting, ventilation and access to the actual connectors.
4Plan the connectionsMake affected circuits safe and verify the specified DC supply, polarity and protective-earth arrangement before connecting.
5Control the changeRetain a controlled project backup and record network addresses, serial settings and installed expansion hardware.
6Verify operationRestore the approved application in a safe state, inspect diagnostics and verify the required I/O and communication functions.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
HoneywellMEL-BSSRT

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMEL-BSSRT-CC

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-AH04A

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-DC04C

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-DV04A

A separate product reference; verify its own installation and configuration.

Specialist model
HoneywellMLF-DV04C

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for PM592-ETH-XC selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

PM592-ETH-XC FAQ

What is the integrated flashdisk capacity of PM592-ETH-XC?The CPU includes a 4 GB non-removable user flashdisk. Plan the application files and data-storage function for that resource separately from the control-program and working-data memory.
Does the PM592-ETH-XC flashdisk increase its compiled program limit?No. The user program allocation remains 4096 kB. File-storage capacity and executable program memory are different resources and should not be combined when checking application size.
Can the internal PM592-ETH-XC flashdisk be treated as a removable SD card?It is identified as non-removable integrated flash storage. A plug-in memory card is a separate arrangement with its own approved type and backup procedure.
Which values should be considered when planning PM592-ETH-XC data retention?The integrated user-data memory is 5632 kB, with 1536 kB identified as saved. Identify the values that must persist and keep an appropriate controlled backup rather than assuming that a file copy preserves every runtime value.
What Ethernet arrangement should be expected for PM592-ETH-XC?Its processor arrangement provides one Ethernet interface. Confirm the terminal base's actual connection and the project's address and access settings before restoring network service.
How are serial field devices matched to PM592-ETH-XC?Confirm the electrical mode and communication configuration of the two configurable RS232/RS485 interfaces against each connected device. Preserve the actual terminal and cable assignments during a replacement.
What power verification is needed when fitting PM592-ETH-XC?Use the specified 24 VDC supply arrangement and verify polarity, grounding and the complete station power requirement. Do not assign a field-load capacity from the CPU input-voltage marking.
How does the PM592-ETH-XC local display assist a controlled restart?The LC display and eight function keys support status and diagnostic checks during restart. Use those indications alongside the approved application state and the actual field-circuit tests.
What should be backed up before PM592-ETH-XC is exchanged?Retain the accepted engineering project, required flashdisk files, relevant retained application values and the station connection record. Confirm the intended restore procedure before removing the old processor.
When can a restored PM592-ETH-XC station be released for use?After the correct project, necessary data and files, network operation and required I/O behavior have been checked under the site's acceptance procedure. A successful power-up alone does not demonstrate complete restoration.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
ABB AC500-XC

Applications & Why Choose Nordwel

Application and maintenance planning for PM592-ETH-XC in the correctly matched installation.

Application areas

01Control and file storageCombines control-program execution with integrated user flash storage for the engineered application.
02Network accessProvides the single Ethernet interface used by the approved project and access arrangement.
03Serial-device integrationMatch the two configurable serial interfaces to the actual connected devices and wiring.
04Service preparationBack up the application and required files and record the station before processor maintenance.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Confirm the complete item, installed arrangement and controlled acceptance results before normal operation.
Need help matching PM592-ETH-XC to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp