other
Products
Control Techniques SM-APPLICATIONS programmable application processor module product photographs
Control Techniques SM-APPLICATIONS programmable application processor module product photographs
Control Techniques SM-APPLICATIONS programmable application processor module product photographs

Control Techniques SM-APPLICATIONS programmable application processor module

EMAIL SALES
Control Techniques Solutions Modules
SM-APPLICATIONS — programmable application processor module

Adds task-based application processing to a compatible drive. CTNet, serial communications and local digital I/O support coordinated machine control.

Control TechniquesSolutions Modulesprogrammable application processor module
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
SM-APPLICATIONS product profile
Product familySolutions Modules
Exact modelSM-APPLICATIONS
Primary roleRuns application-specific control tasks
Serial interfaceEIA-RS485
Digital I/O2 inputs and 2 outputs, 24 V
CTNet rateUp to 5 Mbit/s
  • Brand:

    Others
  • Item NO.:

    SM-APPLICATIONS
SM-APPLICATIONS configuration inquiry

Get a precise quote for SM-APPLICATIONS

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

SM-APPLICATIONS functions and installation

Adds task-based application processing to a compatible drive. CTNet, serial communications and local digital I/O support coordinated machine control.

Application executionRuns a downloaded, task-based control program.
Network arrangementCTNet and EIA-RS485 have different wiring and protocol roles.
Field-signal loadingReview output current and field-circuit insulation before connection.
Controlled restartProve the application and interlocks after replacement.

Installation and selection boundaries

  • Select the actual application processor variant required by the machine project.
  • Back up the program and parameters before disturbing the installed system.
  • Agree whether the module, connectors and engineering work are included in the quotation.
Official product data

SM-APPLICATIONS key specifications

Processor arrangement Dedicated application microprocessor
Power source Host drive internal supply
Serial protocols ANSI; Modbus RTU master/slave; Modbus ASCII master/slave
CTNet link Up to 5 Mbit/s
Digital inputs Two 24 V inputs
Digital outputs Two 24 V positive-logic outputs; up to 20 mA per output
Programming arrangement Task-based application programming
Synchronization CTSync

Control Techniques SM-Applications Modules and Motion Processors User Guide, issue 4, sections 2, 3 and 4.

Pre-order check 01

Installation environment

Fit the module only in a compatible, isolated drive installation.

  • Disconnect AC power, wait at least ten minutes and confirm any DC bus is discharged before module work.
  • Protect the module connector and seat it fully in the designated option slot.
  • Use screened CTNet twisted-pair wiring with correctly arranged network termination.
  • Keep field I/O insulated as required for the drive control-circuit installation.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Host selection
Compare the actual drive option-slot arrangement and approved module support.
Network wiring
Match CTNet and EIA-RS485 wiring separately; the two interfaces are not interchangeable.
Program resources
Retain the actual application project, task configuration and development-tool requirements.
Output loading
Limit each positive-logic digital output to its permitted 20 mA load.
Restart behavior
Validate the application startup and interlocks before returning the machine to service.
Record successful task execution, communications and machine-interlock checks before release.
Recommended model families

Recommended product references

Control TechniquesControl Techniques SM-PROFIBUSControl Techniques SPMD1423Control Techniques SPMD1424

Separate product references; inclusion does not establish compatibility or interchangeability.

General Electric / SiemensGeneral Electric IC600CB513Siemens 6ES7143-5AH00-0BA0General Electric IC600BF914

Separate product references; inclusion does not establish compatibility or interchangeability.

General Electric / Vibro-MeterGeneral Electric IC600BF915Vibro-Meter TQ902-011 111-902-000-011 A1-B1-C42-D2-E10000-F2-G9800-H10Vibro-Meter CA202 144-202-000-205

Separate product references; inclusion does not establish compatibility or interchangeability.

Vibro-Meter / Siemens / Bently NevadaVibro-Meter AF70982 111-412-000-012Siemens 6ES7143-4BF50-0AA0Bently Nevada 330876-03-10-00-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

Schneider Electric / Bently NevadaSchneider Electric S047059 MICROLOGIC 6.0 PBently Nevada 330854-080-24-05Bently Nevada 330104-00-08-15-02-00

Separate product references; inclusion does not establish compatibility or interchangeability.

General Electric / Schneider Electric / Bently NevadaGeneral Electric IC600CB507Schneider Electric ATV61HD75N4Bently Nevada 330103-02-08-10-02-CN

Separate product references; inclusion does not establish compatibility or interchangeability.

Schneider Electric / Bently NevadaSchneider Electric TSXP57302MBently Nevada 330854-080-25-05Schneider Electric AP4423

Separate product references; inclusion does not establish compatibility or interchangeability.

Vibro-Meter / General ElectricVibro-Meter TQ902-011 111-902-000-011 A1-B1-C40-D2-E5000-F0-G0-H05General Electric IC600BF942Vibro-Meter S3960 AC46286 144-201-000-222

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently Nevada / Vibro-MeterBently Nevada 330903-00-07-10-01-00Bently Nevada 330102-00-12-10-01-05Vibro-Meter TQ402 111-402-000-012 A1-B1-D000-E010-F0-G000-H05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently Nevada / General Electric / Vibro-MeterBently Nevada 330903-00-07-10-01-CNGeneral Electric IC600BF940Vibro-Meter TQ403 111-403-000-013 A1-B1-C036-D000-E100-F1-G098-H10

Separate product references; inclusion does not establish compatibility or interchangeability.

Vibro-Meter / Schneider ElectricVibro-Meter CA134 144-134-000-612Schneider Electric RM1-XA315Vibro-Meter TQ402 111-402-000-013 S3960 A1-B1-C042-D000-E010-F0-G000

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES7144-4FF01-0AB0Siemens 6ES7143-5BF00-0BA0Siemens 6GK5308-2FM10-2AA3

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

SM-APPLICATIONS Order Guide

Check the complete requested item against the actual installation before ordering.
1Identify the itemRecord SM-APPLICATIONS exactly as requested, including all marks on the installed unit.
2Capture the installationCompare the actual drive option-slot arrangement and approved module support.
3Define supply scopeAgree whether the module, connectors and engineering work are included in the quotation.
4Check the interfacesMatch CTNet and EIA-RS485 wiring separately; the two interfaces are not interchangeable.
5Plan the workDisconnect AC power, wait at least ten minutes and confirm any DC bus is discharged before module work.
6Document acceptanceRecord successful task execution, communications and machine-interlock checks before release.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
Schneider ElectricATV320U75N4B

A separate product reference; verify its own installation and configuration.

Specialist model
Schneider ElectricPN072132P902 3D658187G901

A separate product reference; verify its own installation and configuration.

Specialist model
Schneider ElectricXS4P18AB120

A separate product reference; verify its own installation and configuration.

Specialist model
Vibro-MeterVM600 RPS6U SIM-275D-24 200-582-200-013

A separate product reference; verify its own installation and configuration.

Specialist model
Vibro-MeterTQ402 111-402-000-012

A separate product reference; verify its own installation and configuration.

Specialist model
Vibro-MeterCA202 144-202-000-215

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for SM-APPLICATIONS selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

SM-APPLICATIONS FAQ

What work does SM-APPLICATIONS perform inside a drive?It provides an additional processor for application-specific software, allowing task-based control beyond the drive's built-in functions. It is an option module, not a complete motor power converter.
Can SM-APPLICATIONS communicate with both serial masters and slaves?Its EIA-RS485 port supports ANSI and Modbus RTU/ASCII master and slave operation. Choose the protocol and port configuration required by the installed application rather than assuming any RS485 device uses the same protocol.
How fast can the SM-APPLICATIONS CTNet connection operate?CTNet supports data rates up to 5 Mbit/s. Use suitable screened twisted-pair cable and correct segment termination; the maximum rate is not a guarantee for arbitrary cabling.
What local input and output signals are available on SM-APPLICATIONS?The module provides two 24 V digital inputs and two 24 V digital outputs. These are discrete signals, not analog measurement channels.
Can an SM-APPLICATIONS output directly drive a large contactor coil?Check the coil current first. Each positive-logic output supplies up to 20 mA; a load requiring more current needs a correctly engineered interface rather than a direct connection.
Does SM-APPLICATIONS need its own external power supply?The processor module is powered from the host drive's internal supply. External field circuits still need the correct supply, references and insulation for their individual connections.
Is it safe to insert SM-APPLICATIONS with the drive energized?No. Isolate AC power for at least ten minutes and ensure any DC bus supply is discharged before installing or removing the module. A stopped motor does not establish electrical isolation.
What should be retained before an SM-APPLICATIONS replacement?Preserve the application source project, downloaded program, task setup and relevant drive parameters. A replacement module must be loaded and commissioned for the actual machine function.
Why can SM-APPLICATIONS digital outputs switch off together?The outputs include short-circuit and overload protection. If the protection trips, both outputs are deactivated; check the connected loads and wiring before resetting or restarting.
How should an SM-APPLICATIONS installation be accepted after programming?Test task execution, serial/CTNet exchanges, local I/O and the machine's startup interlocks under controlled conditions. Release the machine only after the loaded application behaves as intended.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
Control Techniques Solutions Modules

Applications & Why Choose Nordwel

Application and maintenance planning for SM-APPLICATIONS in the correctly matched installation.

Application areas

01Custom drive sequencingExecute machine-specific tasks in SM-APPLICATIONS within the approved host drive.
02Coordinated equipmentUse CTNet for the application's designed process-data exchange.
03Serial integrationConnect appropriately configured serial equipment through EIA-RS485.
04Local discrete signalsHandle low-current status and control signals through the module digital I/O.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Record successful task execution, communications and machine-interlock checks before release.
Need help matching SM-APPLICATIONS to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp