other
Products
Bently Nevada 133819-01 internally terminated RTD/TC I/O module product views
Bently Nevada 133819-01 internally terminated RTD/TC I/O module product views
Bently Nevada 133819-01 internally terminated RTD/TC I/O module product views

Bently Nevada 133819-01 RTD/TC non-isolated I/O module with internal terminations

EMAIL SALES
Bently Nevada 3500/60 temperature monitoring
133819-01 — RTD/TC non-isolated I/O module with internal terminations

Connects RTD and thermocouple signals to a 3500/60 temperature monitor. Internal terminations support direct field wiring in the matched non-isolated installation.

Bently Nevada3500/60 temperature monitoringRTD / TC I/O module
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
133819-01 product profile
Product family3500/60
Exact model133819-01
Sensor inputsRTD and thermocouple
Termination arrangementInternal terminations
Isolation variantNon-isolated
Rack locationOne full-height rear slot
  • Brand:

    Bently Nevada
  • Item NO.:

    133819-01
  • Part Number:

    133819-01
  • Weight:

    0.4 kg
  • Dimensions:

    2.6x11.2x24.2cm
  • Manufacture Year:

    The latest year
  • Place of Origin:

    USA
  • Certification:

    COO
  • Description:

    Bently Nevada | 133819-01 | I/O MODULE
133819-01 configuration inquiry

Get a precise quote for 133819-01

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

133819-01 functions and installation

The rear I/O module provides the sensor connection arrangement for the temperature-monitoring channel configuration. Select it against the installed monitor, transducer types and terminal schedule; the I/O assembly is not a stand-alone temperature controller.

Sensor allocationMatch each configured channel to the RTD or thermocouple actually connected.
Field terminationReview conductor assignment at the internal terminal connectors.
Rack integrationConfirm the rear I/O assembly matches the installed temperature monitor.
Acceptance planningCheck the displayed temperature and configured alarm response before handover.

Installation and selection boundaries

  • Non-isolated input configurations can combine RTD and thermocouple channels.
  • The 3500/60 monitoring arrangement does not provide recorder outputs.
  • Record the sensor type, measuring range and terminal connections before replacement.
Official product data

133819-01 key specifications

Monitor signal capacity 1–6 RTD or thermocouple signals in the matched monitoring arrangement
Input impedance 10 MΩ per lead input
RTD connection formats 3-wire or 4-wire, with a supported RTD type selected in configuration
Thermocouple types E, J, K and T; select the corresponding channel configuration
I/O dimensions, H × W × D 241.3 × 24.4 × 99.1 mm
I/O module weight 0.45 kg
Operating temperature −30 to +65 °C for the internal-termination I/O arrangement
Storage temperature −40 to +85 °C

Bently Nevada 3500/60 and 3500/61 Temperature Modules, datasheet 141540 Rev. L; input specifications, physical data and 3500/60 spare-parts listing.

Pre-order check 01

Installation environment

Plan rear-rack access and verify the sensor wiring and configuration before putting the channel back into service.

  • Use the site isolation and maintenance procedure before disturbing field conductors; do not treat a rack configuration as permission for live rewiring.
  • Provide access for one full-height rear I/O slot and check the module outline against the installed rack.
  • Record RTD lead assignments or thermocouple polarity before moving wiring to the replacement assembly.
  • After installation, compare the channel reading with a known input and check the configured alarm response under controlled conditions.
Retain the approved installation drawing and record the controlled acceptance checks.
Pre-order check 02

Compatibility confirmation

Match the complete item, actual connections and required installed function.

Monitor arrangement
Match the I/O module to the 3500/60 temperature-monitor installation.
Termination method
Use the internal-termination wiring arrangement; an external-termination installation is a different selection.
Sensor configuration
Confirm RTD type and wire count, or thermocouple type and polarity, against each configured channel.
Isolation requirement
This is the non-isolated variant; do not assume the isolated thermocouple version’s channel-to-channel rating.
Measurement setup
Retain the approved range and alarm settings and verify the measurement chain after replacement.
Confirm the complete spare number, rear I/O arrangement and sensor schedule together before releasing the replacement for use.
Recommended model families

More Bently Nevada models

Bently NevadaBently Nevada 330854-080-25-05Bently Nevada 330854-080-24-05Bently Nevada 330130-070-01-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330130-075-01-00Bently Nevada 330104-00-08-15-02-00Bently Nevada 330102-00-12-10-01-05

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330103-02-04-10-02-CNBently Nevada 330103-02-08-10-02-CNBently Nevada 330905-00-25-05-02-CN

Separate product references; inclusion does not establish compatibility or interchangeability.

Bently NevadaBently Nevada 330903-00-07-10-01-CNBently Nevada 330903-00-07-10-01-00Bently Nevada 330876-03-10-00-00

Separate product references; inclusion does not establish compatibility or interchangeability.

Additional published brands

Additional Advantage Models

SiemensSiemens 6ES7143-5BF00-0BA0Siemens 6ES7144-5KD00-0BA0Siemens 6ES7144-4PF00-0AB0

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES7144-4JF00-0AB0Siemens 6ES7144-4FF01-0AB0Siemens 6ES7144-1JB31-0XB0

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES7144-1GB31-0XB0Siemens 6GK5308-2FM10-2AA3Siemens 6ES7143-5AH00-0BA0

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES7143-4BF50-0AA0Siemens 6ES7142-6BH00-0AB0Siemens 6GK1143-0TA02

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6GK1143-0AA01Siemens 6ES5951-7LB21Siemens 6ES5948-3UA23

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES5948-3UA13Siemens 6ES5945-7UA23Siemens 6ES5941-7UA12

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES5921-3WB12Siemens 6ES5541-8AA11Siemens 6ES5470-4UC13

Separate product references; inclusion does not establish compatibility or interchangeability.

SiemensSiemens 6ES5465-4UA13Siemens 6ES5464-8MF21Siemens 6ES5464-8ME11

Separate product references; inclusion does not establish compatibility or interchangeability.

Every model above links to an existing Nordwel product page. Send the full part number for configuration and availability confirmation. CHECK WITH SALES

133819-01 Order Guide

Check the complete requested item against the actual installation before ordering.
1Identify the spareMatch the complete module marking with the installed assembly and order.
2Record the hostIdentify the fitted temperature monitor and rear-rack position.
3List sensor circuitsRecord each RTD or thermocouple type and its assigned channel.
4Review terminalsCheck internal-termination conductors, polarity and RTD lead count.
5Preserve settingsRetain the range, engineering units and alarm settings for the installation.
6Plan commissioningAgree input simulation, temperature-reading and alarm checks before handover.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Compare the complete identity, installed hardware and application requirements before selection.
vibro-meterVM600 RPS6U SIM-275D-24 200-582-200-013 DC

A separate product reference; verify its own installation and configuration.

Specialist model
ABBV18345-1010261001

A separate product reference; verify its own installation and configuration.

Specialist model
ABB3HAC061275-001

A separate product reference; verify its own installation and configuration.

Specialist model
ABBPM5132-T-ETH

A separate product reference; verify its own installation and configuration.

Specialist model
ABBPM5112-R-ETH

A separate product reference; verify its own installation and configuration.

Specialist model
ABBPM5072-T-ETH

A separate product reference; verify its own installation and configuration.

Specialist model
Nordwel customer support

Company Services & FAQ

Support for 133819-01 selection, quotation and controlled replacement planning.

Company services

Item and application reviewCompare the complete item with the installed configuration and required supplied scope.
Fast quotation supportConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide shipping coordinationConfirm destination, freight option, packing requirements and shipment tracking workflow.
Order follow-upProvide pre-order clarification and shipment-status support through the assigned sales contact.

133819-01 FAQ

Does 133819-01 include the front temperature monitor?It is the rear RTD/TC I/O module for the 3500/60 arrangement. The front monitor is a separate assembly; identify the required supplied scope on the order rather than assuming both assemblies are included.
Can RTD and thermocouple circuits be mixed on this non-isolated arrangement?Yes. The supported non-isolated configuration can use RTD inputs, thermocouple inputs or a mixture. Configure each channel for its actual sensor type rather than connecting mixed circuits to an unchanged setup.
Does internal termination mean an external terminal block is required?No. This spare is the internal-termination variant, with field connections at the I/O assembly. External-termination hardware belongs to a different wiring arrangement and must not be assumed interchangeable.
Is 250 VDC channel-to-channel isolation a rating of this module?No. That figure applies to the isolated thermocouple version in the product family. 133819-01 is explicitly non-isolated, so selection must account for the actual field grounding and isolation requirement.
Which RTD lead arrangements can the matched monitor accept?Supported RTD types use three-wire or four-wire connections. Select the correct material and resistance characteristic in configuration, then match the conductor assignment to that connection format.
What must be checked when changing a channel from one thermocouple type to another?The supported thermocouple types are E, J, K and T. Match the selected channel type, polarity and configured measurement range to the installed sensor before accepting the reading.
How much rear-rack space and physical clearance should be reviewed?The I/O assembly requires one full-height rear slot. Its specified outline is 241.3 mm high, 24.4 mm wide and 99.1 mm deep; also allow practical access for the fitted field wiring.
Does this 3500/60 installation provide a recorder output for each temperature channel?No. The 3500/60 arrangement is the version without recorder outputs. This I/O spare must not be selected on the assumption that it adds a per-channel current recorder interface.
What operating ambient limit applies to the internal-termination arrangement?The specified operating range is −30 to +65 °C for the arrangement using internal or external termination I/O. Storage limits are separate and do not authorize operation outside that range.
Are temperature ranges fixed by the spare number alone?No. The monitor’s full-scale range is set for each channel through the rack configuration software and must remain within the selected sensor’s supported range. Check those settings and the alarm setpoints when commissioning the replacement.
Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
Bently Nevada 3500/60 temperature monitoring

Applications & Why Choose Nordwel

Application and maintenance planning for 133819-01 in the correctly matched installation.

Application areas

01Machine temperature channelsConnect supported RTD or thermocouple circuits to the matched monitoring channel setup.
02Mixed-sensor installationsPlan individual RTD and thermocouple channel assignments within the non-isolated arrangement.
03Rear I/O replacementUse the full spare identity and terminal record to prepare a controlled rack maintenance task.
04Monitoring-chain verificationCompare known sensor inputs with the configured readings and alarms after installation.

Why choose Nordwel

Configuration-aware supportReview complete identity, installation conditions and the required application before quotation.
Fast quotationConfirm pricing, availability and lead time against current Nordwel business records.
Worldwide coordinationSupport destination, freight, packing and shipment-tracking requirements.
Dedicated sales contactWork directly with an assigned contact for pre-order clarification and order follow-up.
Confirm the complete spare number, rear I/O arrangement and sensor schedule together before releasing the replacement for use.
Need help matching 133819-01 to your installation?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
Control, Power & Communication6ES59417UA12Siemens S5 module reference; confirm the installed rack function.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
Control, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
Control, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
Control, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
Control, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
Control, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
Control, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
Control, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp