AAI835-S00 S2 — Analog I/O Module

Yokogawa identifies AAI835 as a 4 to 20 mA analog I/O module with 4 isolated input channels and 4 isolated output channels.

CENTUM VP Field I/OAnalog I/O ModuleStyle S2 review
Sales contactStella
Tel / WhatsApp+8618159889985
Officially reviewed product profile
Product familyCENTUM VP Field I/O
Exact modelAAI835-S00 S2
Product typeAnalog I/O Module
ManufacturerYokogawa
I/O signal4 to 20 mA
Channels4 input / 4 output
IsolationIsolated channels
StyleS2
  • Brand:

    Others
  • Item NO.:

    AAI835-S00 S2
  • Goods Stock:

    1
  • Part Number:

    AAI835-S00 S2
  • Weight:

    Approx. 0.30 kg
  • Dimensions:

    32.8 × 130 × 107.5 mm (W × H × overall D; 94 mm body depth shown)
  • Description:

    Yokogawa AAI835-S00 S2 analog I/O module with four isolated 4 to 20 mA input channels and four isolated 4 to 20 mA output channels. Confirm the complete suffix, style, node, terminal equipment, cable and manufacturer documentation before ordering.
AAI835-S00 S2 configuration inquiry

Get a precise quote for Yokogawa AAI835-S00 S2

Email Sales
Sales contactStella
WhatsApp+8618159889985

AAI835-S00 S2 official identification

Yokogawa identifies AAI835 as an analog I/O module for 4 to 20 mA signals with 4 isolated input channels and 4 isolated output channels.

Complete modelAAI835-S00 S2
Documented familyCENTUM VP Field I/O
Verified function4 to 20 mA analog input and output
Interface or ordering fact4 isolated input channels / 4 isolated output channels

Engineering and installation checks

  • Keep AAI835-S00 and Style S2 together in the quotation, nameplate record and receiving inspection.
  • Confirm the installed node unit, slot, redundancy arrangement, terminal block, cable and suffix code.
  • Manufacturer verification basis: Yokogawa Analog I/O Modules General Specifications GS 33J60F60-01EN.
Official product data

AAI835-S00 S2 key specifications

Manufacturer Yokogawa
Complete model AAI835-S00 / Style S2
I/O signal Input: 4 to 20 mA; Output: 4 to 20 mA
I/O channels 4 input / 4 output; isolated channels
Data update period 10 ms
External connection Pressure clamp terminal, MIL connector cable or dedicated KS1 cable
Dimensions 32.8 × 130 × 107.5 mm (W × H × overall D; 94 mm body depth shown)
Weight Approx. 0.30 kg

Source: Yokogawa Analog I/O Modules General Specifications — https://web-material3.yokogawa.com/GS33J60F60-01EN.pdf

Pre-order check 01

Module, slot and connection review

Verify the node unit, slot, terminal arrangement, field wiring and approved operating environment before installation.

  • Confirm the installed CENTUM VP Field I/O node and single or dual-redundant arrangement.
  • Record all 4 input and 4 output channel assignments and the existing 4 to 20 mA loops.
  • Verify the specified terminal block or adapter, KS1 or MIL cable, and field wiring.
  • Confirm the complete suffix, Style S2 nameplate and any explosion-protection requirement.
Record the as-found configuration and controlled loop checks in the commissioning file.
Pre-order check 02

Compatibility confirmation

Match AAI835-S00 S2 to the installed Field I/O node, terminal equipment, cable and redundancy configuration.

Complete model
AAI835-S00 S2
I/O channels
Input: 4 to 20 mA; Output: 4 to 20 mA
Signal and isolation
4 to 20 mA; channels isolated from field/system and each other
Accuracy
Input ±16 µA; output ±48 µA
Maximum current consumption
360 mA at 5 V DC; 450 mA at 24 V DC
Final selection: Confirm AAI835-S00 S2, node unit, slot, terminal equipment, cable, redundancy and Yokogawa documentation.
Related product references

More Yokogawa CENTUM VP Field I/O Models

Cross-brand references

Additional Advantage Models

ABBABB PM861AK01 3BSE018157R1ABB PSM0004 2RCA025059A0001RABB CI840A 3BSE041882R1

These references are not direct substitutes for AAI835-S00 S2.

Bently NevadaBently Nevada 330104-01-08-05-11-05Bently Nevada 330905-00-18-05-02-05Bently Nevada 330105-02-12-15-02-05

These references are not direct substitutes for AAI835-S00 S2.

SiemensSiemens 6GK5208-0BA00-2AB2Siemens 6ES7153-2BA02-0XB0Siemens 6ES7214-1AD22-0XB0

These references are not direct substitutes for AAI835-S00 S2.

Allen-BradleyAllen-Bradley 1715-A3IOAllen-Bradley 1768-L43Allen-Bradley 1756-ENBT

These references are not direct substitutes for AAI835-S00 S2.

GEGE 323A3347P5GE CRS-10-MBGE IC693MDL753E

These references are not direct substitutes for AAI835-S00 S2.

HoneywellHoneywell RM7823A1016Honeywell C7232B5820Honeywell T7412B1008

These references are not direct substitutes for AAI835-S00 S2.

ICS Triplex / TriconexICS Triplex T8313 5020-301ICS Triplex T8123 PoE-30WTriconex 3503E

These references are not direct substitutes for AAI835-S00 S2.

EmersonEmerson KJ3241X1-BA1 12P2506X032Emerson KJ3224X1-BA2 13P0137X022Emerson KJ2005X1-SQ1 12P6383X052

These references are not direct substitutes for AAI835-S00 S2.

Confirm manufacturer, complete model, suffix, style and installed-system compatibility before ordering.INQUIRY NOW

Yokogawa AAI835-S00 S2 Order Guide

Use the complete Yokogawa model, suffix, style, node unit, terminal equipment and cable record for engineering review.
1Exact identityRetain AAI835-S00 and Style S2 exactly as shown on the nameplate and Yokogawa documentation.
2Product familyYokogawa CENTUM VP Field I/O / Analog I/O Module
3Primary functionFour isolated 4 to 20 mA input channels and four isolated 4 to 20 mA output channels.
4Mechanical checkConfirm the installed node unit, slot and single or dual-redundant module arrangement before ordering.
5Connection checkVerify the pressure clamp terminal, MIL cable or dedicated KS1 cable and the exact terminal equipment.
6Official sourceYokogawa GS 33J60F60-01EN Analog I/O Modules General Specifications

Yokogawa AAI835 Configuration References

Official Field I/O modules, terminal blocks and adapters for configuration review.

These references are not automatic substitutes.
Confirm model, suffix, style, node, terminal equipment, cable and installed configuration before ordering.
YOKOGAWA / TARGET MODULEAAI835-S00 S2

Target 4-input/4-output isolated current I/O module, standard type, Style S2.

Yokogawa configuration reference
YOKOGAWA / RELATED MODULEAAI135-S50

Eight-channel isolated 4 to 20 mA input module; not a substitute for AAI835.

Yokogawa configuration reference
YOKOGAWA / TERMINAL BLOCKATI3S-00

Pressure clamp terminal block for isolated analog signals.

Yokogawa configuration reference
YOKOGAWA / DUAL TERMINAL BLOCKATI3D-00

Dual pressure clamp terminal block for isolated analog signals.

Yokogawa configuration reference
YOKOGAWA / KS ADAPTERATB3A-00

KS cable interface adapter used with AAI835 terminal-board arrangements.

Yokogawa configuration reference
YOKOGAWA / KS ADAPTERATK4A-00

KS cable interface adapter for supported analog I/O arrangements.

Yokogawa configuration reference
Nordwel Yokogawa AAI835-S00 S2 support

Company Services & FAQ

Configuration-aware support for model verification, compatibility review, quotation and shipment coordination.

Support scope

Model verificationCompare AAI835-S00, Style S2 and the installed nameplate.
Compatibility reviewCheck node unit, slot, redundancy, terminal equipment, cable, field signals and application context.
Quotation coordinationConfirm quantity, availability, lead time, destination and required terminal equipment.
Documentation boundaryUse only Yokogawa-published facts; undocumented values and site suitability are not inferred.

AAI835-S00 S2 FAQ

How should engineers identify AAI835-S00 S2 before approving a replacement?

Match AAI835-S00, Style S2, the installed nameplate, node unit, slot and connection hardware. A family match alone is not sufficient.

Which documented family contains AAI835?

AAI835 is documented by Yokogawa as a CENTUM VP Field I/O analog I/O module. Confirm the complete suffix, style and approved system documentation before release.

What is the first compatibility check for AAI835-S00 S2?

Verify the host node, slot and single or dual-redundant arrangement, then confirm all 4 input and 4 output channel assignments.

What installation detail is critical for AAI835-S00 S2?

Confirm the exact terminal block or adapter, KS1 or MIL cable, and retain the wiring and inspection record with the maintenance package.

Which connection facts must be confirmed for AAI835-S00 S2?

Confirm 4 to 20 mA input/output loops, channel isolation, field wiring, terminal equipment and cable before energizing.

Can AAI835-S00 S2 be substituted by another analog I/O model?

Not automatically. Related modules differ in channel count, isolation, signal type, communication and connection hardware. Use the exact code and style.

What environmental review applies to AAI835-S00 S2?

Use the limits in the applicable Yokogawa installation guidance and confirm the actual node, cabinet and site conditions.

What dimensions and weight are documented for AAI835?

The official drawing shows 32.8 mm width, 130 mm height and 107.5 mm overall depth with 94 mm body depth; approximate weight is 0.30 kg.

What should a sourcing request for AAI835-S00 S2 include?

Provide AAI835-S00, Style S2, quantity, destination, node model, terminal equipment, cable, nameplate images and schedule. Stella can coordinate the review.

What manufacturer-data boundary applies to this AAI835-S00 S2 review?

Only values traceable to Yokogawa official material are used. Final suitability still requires the approved project documentation and installed configuration.

Sales contactStella
WhatsApp+8618159889985
YOKOGAWA / CENTUM VP FIELD I/O

CENTUM VP Field I/O Model Directory

Analog I/O modules, terminal equipment and cable-interface references.

Isolated current I/O modules

AAI835-S00 S2Target 4-input/4-output isolated current I/O module.
AAI135-S50Eight-channel isolated current input module.
AAI143-S50Sixteen-channel isolated current input module.
AAI543-S50Sixteen-channel isolated current output module.
AAI841-S50Eight-input/eight-output current I/O module.
AAB141-H50Sixteen-channel voltage/current input module.
AAB841-S50Eight-input/eight-output voltage/current I/O module.

Analog input/output module families

AAB842-H50Eight-input/eight-output voltage/current I/O module.
AAI141-S50Sixteen-channel current input module.
AAV144-S50Sixteen-channel isolated voltage input module.
AAV544-S50Sixteen-channel isolated voltage output module.
AAP135-S50Eight-channel isolated pulse input module.
ATI3S-00Pressure clamp terminal block for isolated analog.
ATI3D-00Dual pressure clamp terminal block for isolated analog.

Terminal blocks, adapters & boards

ATB3A-00KS cable interface adapter for AAI835.
ATK4A-00KS cable interface adapter for analog modules.
AEA4DTerminal board for analog module connections.
AEA3DTerminal board used with the AAI835 ATB3A arrangement.
These Yokogawa references are system-related products, not direct substitutes for AAI835-S00 S2. Confirm each complete model, suffix and style before ordering.
YOKOGAWA / CONNECTION COMPONENTS

Terminal, Adapter and Cable References

Officially documented terminal blocks, adapters, boards and cable references for AAI835 configuration review.

YOKOGAWA · CONFIGURATION COMPONENT
ATI3S-00

Pressure clamp terminal block for isolated analog signals.

YOKOGAWA · CONFIGURATION COMPONENT
ATI3D-00

Dual pressure clamp terminal block for isolated analog signals.

YOKOGAWA · CONFIGURATION COMPONENT
ATB3A-00

KS cable interface adapter for AAI835 terminal-board connection.

YOKOGAWA · CONFIGURATION COMPONENT
ATK4A-00

KS cable interface adapter for AEA4D arrangements.

YOKOGAWA · CONFIGURATION COMPONENT
AEA4D

Analog terminal board for supported Field I/O arrangements.

YOKOGAWA · CONFIGURATION COMPONENT
AEA3D

Analog terminal board for AAI835 with ATB3A.

YOKOGAWA · CONFIGURATION COMPONENT
KS1

Dedicated cable used in supported module connections.

YOKOGAWA · CONFIGURATION COMPONENT
ACCC01

Connector cover for MIL cable connection.

YOKOGAWA · CONFIGURATION COMPONENT
CENTUM VP Node Unit

Installed host equipment whose exact model and slot must be confirmed.

These references are not automatic substitutes. Confirm AAI835-S00 S2, node unit, terminal equipment, cable and field-loop requirements before quotation.
Yokogawa CENTUM VP Field I/O application review

AAI835-S00 S2 Applications

Application contexts based on the documented isolated current I/O role; final suitability depends on the complete CENTUM VP configuration and Yokogawa documentation.

Application contexts

01 · Isolated 4–20 mA input loopsUse AAI835-S00 S2 only where four isolated 4 to 20 mA input channels match the approved system design.
02 · Isolated 4–20 mA output loopsUse the module only where four isolated 4 to 20 mA output channels match the approved field-device arrangement.
03 · Dual-redundant I/O configurationsConfirm identical module suffixes, adjacent slots, terminal equipment and Yokogawa redundancy requirements before use.
04 · Configuration-controlled module replacementMatch the complete model, suffix, style, node, slot, terminal equipment and cable before replacing an existing module.

Why choose Nordwel

Exact-model controlKeep AAI835-S00 and Style S2 together in every quotation and replacement record.
Technical cautionSeparate Yokogawa-verified product data from loop design and site-specific engineering decisions.
Fast coordinationReview model, suffix, style, node, terminals, cable, quantity, destination and schedule in one inquiry.
Dedicated contactStella manages pre-order clarification and follow-up.
Best fit: CENTUM VP configurations whose approved drawings and parts list specify AAI835-S00 S2. Check first: Confirm node, slot, redundancy, terminal equipment, cable and all field-loop assignments.
Need help matching this Yokogawa I/O module?INQUIRY NOW
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & CommunicationIS200STAIH2ADCGE analog terminal board reference; confirm the installed I/O arrangement.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
These industrial spare references are not direct substitutes for AAI835-S00 S2. Confirm manufacturer, complete model, revision and installed-system compatibility before ordering.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp