other
Products
ABB CI501-PNIO official product image
ABB CI501-PNIO official product image
ABB CI501-PNIO official product image

ABB CI501-PNIO S500 PROFINET Interface Module

EMAIL SALES
ABB official data verified
CI501-PNIO — PROFINET Interface Module

CI501-PNIO is a PROFINET IO RT device with four analog inputs, two analog outputs, eight 24 V DC digital inputs and eight 24 V DC transistor outputs. Confirm CI501-PNIO order 1SAP220600R0001, PROFINET station settings, terminal unit, I/O map and device index before replacement.

AC500 / S500PROFINET Interface Module24 V DC process supplyCI501-PNIO
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
Officially verified product profile
Product familyAC500 / S500
Exact modelCI501-PNIO
Module typePROFINET Interface Module
Electrical profile24 V DC process supply
Verified feature4 AI; 2 AO; 8 DI; 8 DO
Selection boundaryConfirm complete ABB revision
Interface / order detailTU507-ETH or TU508-ETH
Engineering applicationPROFINET remote mixed I/O
  • Brand:

    ABB
  • Item NO.:

    CI501-PNIO
  • Goods Stock:

    1
  • Part Number:

    CI501-PNIO
  • Description:

    CI501-PNIO PROFINET Interface Module for AC500 / S500
CI501-PNIO configuration inquiry

Get a precise quote for CI501-PNIO

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

CI501-PNIO official identification

ABB identifies CI501-PNIO as a PROFINET Interface Module in the AC500 / S500 family. CI501-PNIO is a PROFINET IO RT device with four analog inputs, two analog outputs, eight 24 V DC digital inputs and eight 24 V DC transistor outputs.

Complete modelCI501-PNIO
Documented platformAC500 / S500
Verified function4 AI; 2 AO; 8 DI; 8 DO
Interface or ordering factTU507-ETH or TU508-ETH

Engineering and installation checks

  • Confirm CI501-PNIO order 1SAP220600R0001, PROFINET station settings, terminal unit, I/O map and device index before replacement.
  • Confirm the terminal unit, I/O expansion, process wiring, network configuration, firmware and hardware index before replacement.
  • Manufacturer verification basis: ABB CI501 data sheet 3ADR010013 and AC500 hardware manual.
Official product data

CI501-PNIO key specifications

Product familyAC500 / S500
ProtocolPROFINET IO RT device
Analog inputs4
Analog outputs2
Digital inputs8 × 24 V DC
Digital outputs8 × 24 V DC, 0.5 A
Terminal unitTU507-ETH or TU508-ETH
Order code1SAP220600R0001
Weight0.20 kg

Source: ABB CI501 data sheet 3ADR010013 and AC500 hardware manual.

Pre-order check 01

Installation environment

Verify the Ethernet terminal unit, mixed-signal wiring and network identity before replacing the interface module.

  • Mount CI501-PNIO on TU507-ETH or TU508-ETH.
  • De-energize process and module supplies before wiring changes.
  • Record the station name, IP settings, device index and analog channel modes.
  • Verify 24 V DC field supply, Ethernet topology and attached S500 I/O modules.
Retain the network identity, process-data map and all analog channel modes with the commissioning record.
Pre-order check 02

Compatibility confirmation

Match the interface module to the fieldbus role, mixed I/O configuration and terminal unit.

Network role
PROFINET IO RT device
Integrated I/O
4 AI, 2 AO, 8 DI and 8 DO
Terminal hardware
TU507-ETH or TU508-ETH
Control project
Existing station identity and I/O configuration
Replacement check
Match order code, GSDML, firmware and device index
Final selection: confirm every row against the complete model, installed assembly and approved project documentation.
Recommended model families

More ABB models

ABB VERIFIED MODELS 01ABB NTR012-AABB NDBU-95 64008366DABB RAI02J

Each target page displays Tiffany Guan and sales2@mooreplc.com.

ABB VERIFIED MODELS 02ABB PFEA113 3BSE028144R0020ABB 3BHE037649R0101 PDD500A101ABB 3BHE019633R0101 PDD200A101

Each target page displays Tiffany Guan and sales2@mooreplc.com.

ABB VERIFIED MODELS 03ABB 3BHE015619R0001 XVD825A01ABB DSTA002B / 3BSE018317R1ABB 3BHE037864R0104 UFC911 B104

Each target page displays Tiffany Guan and sales2@mooreplc.com.

ABB VERIFIED MODELS 04ABB RB4C-355/170 3AXD50000006934ABB 086364-001ABB ACS880-04-330A-7

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Additional published brands

Additional Advantage Models

TIFFANY VERIFIED MODELS 01Bently Nevada 330104-00-07-05-02-00Bently Nevada 3500/92 136180-01Bently Nevada 3500/42M 176449-02

Each target page displays Tiffany Guan and sales2@mooreplc.com.

TIFFANY VERIFIED MODELS 02Bently Nevada 330730-040-01-05Bently Nevada 144181-51-05Bently Nevada 102045-040-01-05

Each target page displays Tiffany Guan and sales2@mooreplc.com.

TIFFANY VERIFIED MODELS 03Bently Nevada 146054-34-20-02-05GE DS200TCQAG1BFDSchneider PN072132P902 / 3D658187G901

Each target page displays Tiffany Guan and sales2@mooreplc.com.

TIFFANY VERIFIED MODELS 04Schneider BMXDDO1602Schneider BMENOC0301GE SST-PFB3-VME2

Each target page displays Tiffany Guan and sales2@mooreplc.com.

TIFFANY VERIFIED MODELS 05Woodhead SST-DNP-PCI-4SST SST-PB3-SLCVibro-Meter AF70982 / 111-412-000-012

Each target page displays Tiffany Guan and sales2@mooreplc.com.

TIFFANY VERIFIED MODELS 06Vibro-Meter S3960 AC46286 / 144-201-000-222VIPA 315-2AG12 / CPU315SB DPMWestinghouse 5X00241G02

Each target page displays Tiffany Guan and sales2@mooreplc.com.

TIFFANY VERIFIED MODELS 07Westinghouse 5X00058G01Westinghouse 5X00226G01Bently Nevada 200152-XX-XX-XX MOD 323357-10-03-10

Each target page displays Tiffany Guan and sales2@mooreplc.com.

TIFFANY VERIFIED MODELS 08Bently Nevada 86691-02150-0400-15-05Bently Nevada 330171-00-12-05-01-05Bently Nevada 330171-00-33-50-01-05

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Every model above links to an existing Nordwel product page. Confirm the complete model before ordering.CHECK WITH SALES

CI501-PNIO Order Guide

Use the complete ABB model and the installed hardware record for engineering review.
1Exact identityCI501-PNIO must be retained without shortening.
2PlatformAC500 / S500 / PROFINET Interface Module
3Electrical check24 V DC process supply
4Documented feature4 AI; 2 AO; 8 DI; 8 DO
5Connection checkTU507-ETH or TU508-ETH
6Official sourceABB CI501 data sheet 3ADR010013 and AC500 hardware manual

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Recent demand based on Nordwel inquiry records.
Confirm the exact part number before ordering.
SCHNEIDER ELECTRIC / OUTPUT MODULEBMXDDO1602

Output-module reference for control-system projects.

Tiffany-verified target
SCHNEIDER ELECTRIC / ETHERNET MODULEBMENOC0301

Ethernet-module reference for network compatibility review.

Tiffany-verified target
VIBRO-METER / PROXIMITY SENSORAF70982 / 111-412-000-012

Proximity-sensor reference for machinery applications.

Tiffany-verified target
VIBRO-METER / ACCELEROMETERS3960 AC46286 / 144-201-000-222

Accelerometer reference for vibration-monitoring projects.

Tiffany-verified target
WESTINGHOUSE / PROCESSOR MODULE5X00241G02

Processor-module reference for installed control systems.

Tiffany-verified target
ABB / ANALOG INPUT BOARDDSTA002B / 3BSE018317R1

Analog-input board reference for replacement review.

Tiffany-verified target
Nordwel engineering support

Company Services & FAQ

Configuration-aware support for quotation, replacement review and shipment coordination.

Support scope

Model verificationCompare the complete ABB code and installed nameplate.
Compatibility reviewCheck platform, connection hardware, power, firmware and application context.
Quotation coordinationConfirm quantity, availability, lead time and destination.
Documentation boundaryUse only manufacturer-published facts; undocumented values are not inferred.

CI501-PNIO FAQ

How is the exact CI501-PNIO configuration identified for replacement?

Match CI501-PNIO, order code 1SAP220600R0001, device index, PROFINET IO RT device role, terminal unit and the saved station configuration.

What network role does CI501-PNIO perform?

ABB defines CI501-PNIO as a PROFINET IO RT device. Confirm that the controller project expects this role rather than a different Ethernet interface type.

Which local I/O channels are included with CI501-PNIO?

CI501-PNIO provides 4 AI, 2 AO, 8 DI and 8 DO. Preserve the configured signal modes and channel directions when migrating the station.

Which terminal unit should be checked with CI501-PNIO?

Use the documented TU507-ETH or TU508-ETH terminal unit and confirm both its connector style and installed wiring before quotation.

Can CI501-PNIO be selected only by matching the Ethernet connector?

No. An RJ45 connection does not identify the protocol, I/O map, station behavior or terminal unit. Use the full ABB type and order code.

What project data should be backed up before replacing CI501-PNIO?

Retain network identity, address settings, process-data mapping, channel parameters, diagnostics and the controller project version.

How should the connected S500 expansion be checked for CI501-PNIO?

List every attached module in physical order and verify power, supported device indices, I/O-bus limits and project mapping before commissioning.

What commissioning checks are appropriate for CI501-PNIO?

Confirm link and status indications, controller diagnostics, station discovery, input states, output interlocks and an end-to-end functional test.

Is the standard CI501-PNIO interchangeable with an XC version?

Do not assume so. The suffix identifies a different environmental variant; match the installed nameplate and approved cabinet conditions.

What should accompany a CI501-PNIO request to Tiffany?

Provide CI501-PNIO, 1SAP220600R0001, quantity, destination, nameplate images, terminal-unit code, network topology and a copy of the relevant I/O map.

Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
AC500 / S500 application review

CI501-PNIO Applications

Typical inquiry contexts based on the documented module function; final suitability depends on the installed system.

Application contexts

01 · PROFINET remote mixed-I/O stationsUse CI501-PNIO only where the ABB-documented function, wiring and environmental limits match the approved project.
02 · Process skids with analog and digital pointsUse CI501-PNIO only where the ABB-documented function, wiring and environmental limits match the approved project.
03 · Machine-cell distributed I/OUse CI501-PNIO only where the ABB-documented function, wiring and environmental limits match the approved project.
04 · Installed CI501-PNIO replacementUse CI501-PNIO only where the ABB-documented function, wiring and environmental limits match the approved project.

Why choose Nordwel

Exact-model controlKeep the complete ABB designation in every quotation and replacement record.
Technical cautionSeparate verified manufacturer data from site-specific engineering decisions.
Fast coordinationReview model, quantity, destination and required schedule in one inquiry.
Dedicated contactTiffany Guan manages pre-order clarification and follow-up.
Best fit: projects whose approved drawings and parts list specify CI501-PNIO. Check first: Confirm CI501-PNIO order 1SAP220600R0001, PROFINET station settings, terminal unit, I/O map and device index before replacement.
Need help matching your ABB configuration?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
PLC, Power & CommunicationIS200STAIH2ADCGE analog terminal board reference; confirm the installed I/O arrangement.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
PLC, Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
PLC, Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
PLC, Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
PLC, Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
PLC, Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
PLC, Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
PLC, Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp