ARM55D-000 — Mechanical Relay Board for Dry Contact Output

A 32-point Yokogawa mechanical relay output board providing normally-open dry contacts for single or dual-redundant FIO output applications.

Yokogawa CENTUM VP FIO hardwareDry-contact output relay interfaceExact-order review
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
Officially reviewed product profile
Product familyYokogawa CENTUM VP FIO hardware
Exact modelARM55D-000
Product typeMechanical Relay Board for Dry Contact Output
Contact points32
Internal supply24 V DC; 0.65 A max.
Field terminalsM4 screws
Maximum load250 V AC: 2 A; 30 V DC: 2 A; 125 V DC: 0.1 A per point
Verified functionDry-contact output relay interface
  • Brand:

    Others
  • Item NO.:

    ARM55D-000
  • Goods Stock:

    1
  • Part Number:

    ARM55D-000
  • Description:

    A 32-point Yokogawa mechanical relay output board providing normally-open dry contacts for single or dual-redundant FIO output applications.
ARM55D-000 configuration inquiry

Get a precise quote for ARM55D-000

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

ARM55D-000 official identification

A 32-point Yokogawa mechanical relay output board providing normally-open dry contacts for single or dual-redundant FIO output applications.

Complete modelARM55D-000
Documented familyYokogawa CENTUM VP FIO hardware
Verified functionDry-contact output relay interface
Interface or ordering factAKB331 for ADV551 or two AKB337 paths for ADV561

Engineering and installation checks

  • Keep the complete designation ARM55D-000 in the quotation and receiving record.
  • Confirm ADV551 or ADV561 pairing and preserve the output-to-relay mapping.
  • Manufacturer verification basis: Yokogawa GS 33J60H60-01EN.
Official product data

ARM55D-000 key specifications

Contact points 32
Contact form Dry, normally open
Field terminals M4 screws
Maximum load 250 V AC: 2 A; 30 V DC: 2 A; 125 V DC: 0.1 A per point
Minimum load 5 V, 10 mA
Internal supply 24 V DC; 0.65 A max.
Ambient 0–50 °C; 10–90 %RH
Size / weight 482.6 mm wide × 132.5 mm high (3U); approx. 2.2 kg

Source: Yokogawa GS 33J60H60-01EN.

Pre-order check 01

Installation environment

Verify the installed mounting, connection and environmental conditions before this exact configuration is removed or energized.

  • Confirm ADV551 or ADV561 pairing and preserve the output-to-relay mapping.
  • Verify each load rating and add suppression for inductive loads as required by the manufacturer.
  • Inspect M4 terminals, board mounting, 24 V supply and grounding.
  • Test outputs individually and verify redundant paths before return to service.
Record the as-found installation and final controlled checks in the commissioning file.
Pre-order check 02

Compatibility confirmation

Match the complete designation to the installed mechanical arrangement, connection and measurement chain.

I/O modules
ADV551 / ADV561
Signal cables
AKB331 / AKB337
Output type
Dry contact, normally open
Configuration
Single / dual-redundant
Field terminals
M4 screws
Final selection: Use the complete ARM55D-000 designation. Confirm the installed I/O module, connection accessories and project release before replacement.
Recommended model families

More Yokogawa models

Yokogawa verified models 01Yokogawa S2SC70D-FA412010Yokogawa ALF111-S50Yokogawa NFLP121-S00

ARM55D-000 — Identity focus: compare Yokogawa S2SC70D-FA412010 and Yokogawa ALF111-S50 by complete model code.

Yokogawa verified models 02Yokogawa NFCCC01Yokogawa NFBU200-S05Yokogawa CP333D S3

ARM55D-000 — Application check: review the documented role of Yokogawa CP333D S3 before selection.

Yokogawa verified models 03Yokogawa ANB10D-427/CU2TYokogawa ANB10D-427/CU2NYokogawa EC402-51

ARM55D-000 — Interface check: confirm Yokogawa ANB10D-427/CU2T connector and communication requirements.

Yokogawa verified models 04Yokogawa AFV30D-A41262Yokogawa SNB10D-425/CU2TYokogawa SNB10D-425/CU2N

ARM55D-000 — Installation check: match Yokogawa SNB10D-425/CU2T mounting and cabinet conditions.

Additional published brands

Additional Advantage Models

Tiffany verified models 01Woodhead SST-DNP-PCI-4Vibro-Meter AF70982 / 111-412-000-012Vibro-Meter S3960 AC46286 / 144-201-000-222

ARM55D-000 — Electrical check: verify Vibro-Meter S3960 AC46286 / 144-201-000-222 supply and signal limits.

Tiffany verified models 02Westinghouse 5X00241G02Westinghouse 5X00058G01Westinghouse 5X00226G01

ARM55D-000 — Revision control: retain every suffix shown for Westinghouse 5X00241G02.

Tiffany verified models 03AREVA MVAJ101RA0802ABently Nevada 21505-00-28-05-02Pepperl+Fuchs RSD-GW3-Ex2.DPE

ARM55D-000 — Replacement scope: treat Bently Nevada 21505-00-28-05-02 as a separate configuration.

Tiffany verified models 04Load Cell Central OM-19-2Schneider AP4423ABB 086364-001

ARM55D-000 — Project matching: reconcile ABB 086364-001 with approved drawings and slot data.

Tiffany verified models 05ABB ACS880-04-330A-7ABB NTR012-AABB NDBU-95 64008366D

ARM55D-000 — Receiving check: inspect the full identity of ABB ACS880-04-330A-7 on arrival.

Tiffany verified models 06ABB RAI02JABB PFEA113 3BSE028144R0020ABB 3BHE037649R0101 PDD500A101

ARM55D-000 — Commissioning note: keep ABB PFEA113 3BSE028144R0020 settings and wiring records distinct.

Tiffany verified models 07ABB 3BHE019633R0101 PDD200A101ABB 3BHE015619R0001 XVD825A01ABB DSTA002B 3BSE018317R1

ARM55D-000 — Availability review: request ABB DSTA002B 3BSE018317R1 using its complete published designation.

Tiffany verified models 08Schneider PN072132P902 / 3D658187G901Schneider BMXDDO1602Schneider BMENOC0301

ARM55D-000 — Final shortlist: select Schneider PN072132P902 / 3D658187G901 only after technical evidence agrees.

Every model above links to an existing Nordwel page. Confirm the complete model before ordering.CHECK WITH SALES

ARM55D-000 Order Guide

Use the complete Yokogawa designation and installed hardware record for engineering review.
1Exact identityARM55D-000 must be retained without shortening or normalizing its suffixes.
2Product familyYokogawa CENTUM VP FIO hardware / Mechanical Relay Board for Dry Contact Output
3Primary functionDry-contact output relay interface
4Mechanical checkADV551 / ADV561
5Connection checkAKB331 for ADV551 or two AKB337 paths for ADV561
6Official sourceYokogawa GS 33J60H60-01EN

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Recent demand based on Nordwel inquiry records.
Confirm the exact part number before ordering.
SCHNEIDER ELECTRIC / OUTPUT MODULEBMXDDO1602

Output-module reference for control-system projects.

Tiffany-verified target
SCHNEIDER ELECTRIC / ETHERNET MODULEBMENOC0301

Ethernet-module reference for network compatibility review.

Tiffany-verified target
VIBRO-METER / PROXIMITY SENSORAF70982 / 111-412-000-012

Proximity-sensor reference for machinery applications.

Tiffany-verified target
VIBRO-METER / ACCELEROMETERS3960 AC46286 / 144-201-000-222

Accelerometer reference for vibration-monitoring projects.

Tiffany-verified target
WESTINGHOUSE / PROCESSOR MODULE5X00241G02

Processor-module reference for installed control systems.

Tiffany-verified target
ABB / ANALOG INPUT BOARDDSTA002B / 3BSE018317R1

Analog-input board reference for replacement review.

Tiffany-verified target
Nordwel engineering support

Company Services & FAQ

Configuration-aware support for quotation, replacement review and shipment coordination.

Support scope

Model verificationCompare the complete Yokogawa code and installed nameplate.
Compatibility reviewCheck mounting, connection, system length, approvals and application context.
Quotation coordinationConfirm quantity, availability, lead time and destination.
Documentation boundaryUse only manufacturer-published facts; undocumented values are not inferred.

ARM55D-000 FAQ

During shutdown preparation, how should ARM55D-000 be identified?

Retain the complete ARM55D-000 designation and compare it with the installed nameplate, approved parts list and removal photographs. A shortened family code is not an exact match.

What official product role is documented for ARM55D-000?

ARM55D-000 is reviewed as Mechanical Relay Board for Dry Contact Output. The documented role is Dry-contact output relay interface; site suitability still depends on the approved project record.

Which host hardware must be checked before fitting ARM55D-000?

Confirm ADV551 / ADV561, the installed carrier or base, keying, adjacent hardware and every mating connection before approval.

What connection evidence is required for ARM55D-000?

The reviewed interface is AKB331 for ADV551 or two AKB337 paths for ADV561. Preserve terminal assignments, cable identification, shielding, grounding and protective-device records before disconnection.

Can a similar suffix replace ARM55D-000 without a separate review?

No. Treat every suffix and revision as configuration-controlled. Compare the complete ordering code and manufacturer documentation before accepting a substitute.

Which installation conditions belong in the ARM55D-000 work pack?

Confirm ADV551 or ADV561 pairing and preserve the output-to-relay mapping. Also record enclosure protection, temperature, humidity, contamination, grounding, mounting direction and access for inspection.

What should technicians test after installing ARM55D-000?

Complete the manufacturer-required power-up checks, diagnostics, channel or signal verification and a controlled functional test. Retain the results with the commissioning record.

What should a quotation request for ARM55D-000 include?

Provide ARM55D-000, quantity, destination, clear nameplate images, installed-system context, mating hardware and required schedule to Tiffany Guan.

Which value leads the specification review for ARM55D-000?

Start with the manufacturer-published value 32, then verify every other listed parameter against the full code and the as-installed configuration.

What data boundary applies to this ARM55D-000 page?

Use the complete ARM55D-000 designation. Confirm the installed I/O module, connection accessories and project release before replacement.

Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
Yokogawa CENTUM VP FIO hardware application review

ARM55D-000 Applications

Typical inquiry contexts based on the documented product role; final suitability depends on the installed system.

Application contexts

01 · Dry-contact output interfacingUse ARM55D-000 only where the manufacturer-documented function and the approved project conditions match.
02 · ADV551 relay-board connectionUse ARM55D-000 only where the manufacturer-documented function and the approved project conditions match.
03 · ADV561 redundant output connectionUse ARM55D-000 only where the manufacturer-documented function and the approved project conditions match.
04 · FIO output retrofitUse ARM55D-000 only where the manufacturer-documented function and the approved project conditions match.

Why choose Nordwel

Exact-model controlKeep the complete designation in every quotation and replacement record.
Technical cautionSeparate verified manufacturer data from site-specific engineering decisions.
Fast coordinationReview model, quantity, destination and required schedule in one inquiry.
Dedicated contactTiffany Guan manages pre-order clarification and follow-up.
Best fit: projects whose approved drawings and parts list specify ARM55D-000. Check first: Confirm ADV551 or ADV561 pairing and preserve the output-to-relay mapping.
Need help matching this Yokogawa configuration?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
Power & CommunicationIS200STAIH2ADCGE analog terminal board reference; confirm the installed I/O arrangement.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp