CE4001S2T2B7 — 32-Channel Dry-Contact Discrete Input Assembly

A Series 2 Plus 32-channel 24 V DC dry-contact input card paired with a simplex mass termination block.

DeltaV M-series Series 2 Plus I/OHigh-density dry-contact status acquisitionExact-order review
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
Officially reviewed product profile
ManufacturerEmerson
Documented familyDeltaV M-series Series 2 Plus I/O
Product form32-Channel Dry-Contact Discrete Input Assembly
Primary functionHigh-density dry-contact status acquisition
Signal directionInput
Channel count32
Input methodDry contact
Field voltage24 V DC
  • Brand:

    Emerson
  • Item NO.:

    CE4001S2T2B7
  • Goods Stock:

    1
  • Part Number:

    CE4001S2T2B7
  • Description:

    A Series 2 Plus 32-channel 24 V DC dry-contact input card paired with a simplex mass termination block.
CE4001S2T2B7 configuration inquiry

Get a precise quote for CE4001S2T2B7

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

CE4001S2T2B7 official identification

A Series 2 Plus 32-channel 24 V DC dry-contact input card paired with a simplex mass termination block.

System roleHigh-density dry-contact status acquisition
Connection boundarySimplex mass termination block
Selection focusConfirm dry-contact wiring, 32-point density and the B7 mass-termination arrangement.
Release evidenceThirty-two-point schedule, mass-cable check, contact wetting review and scan test

Engineering and installation checks

  • undefined
  • Reconcile all 32 dry-contact points with the marshalling schedule.
  • Manufacturer verification basis: Emerson DeltaV M-series Traditional I/O product data sheet.
Official product data

CE4001S2T2B7 key specifications

Signal direction Input
Channel count 32
Input method Dry contact
Field voltage 24 V DC
Electronics Series 2 Plus
Termination Simplex mass termination block
Redundancy Simplex

Source: Emerson DeltaV M-series Traditional I/O product data sheet.

Pre-order check 01

Installation environment

Review the physical, electrical and environmental conditions that control installation of CE4001S2T2B7.

  • Reconcile all 32 dry-contact points with the marshalling schedule.
  • Seat the mass-termination connection without bent pins or displaced keying.
  • Separate spare cores from active contact pairs before insulation checks.
  • Simulate grouped and individual changes to confirm channel order.
Record the as-found condition and the final thirty-two-point schedule, mass-cable check, contact wetting review and scan test
Pre-order check 02

Compatibility confirmation

Close each documented selection boundary for CE4001S2T2B7 before purchase approval.

Point density
32 inputs
Contact source
Dry-contact circuits
Card generation
Series 2 Plus
Termination style
Simplex mass termination
Redundancy mode
Single card path
Final selection: Use only the values published for CE4001S2T2B7 in Emerson DeltaV M-series Traditional I/O product data sheet; site suitability remains an engineering decision.
Recommended model families

More Emerson models

Emerson verified models 01Emerson VE3012Emerson VE3051C1Emerson VE3051C2

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Emerson verified models 02Emerson VE3051C3Emerson VE3051C4Emerson KJ4002X1-BA1

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Emerson verified models 03Emerson KJ4002X1-CA1Emerson KJ3002X1-BH1Emerson VE4005S2B2

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Emerson verified models 04Emerson VE4005S2B3Emerson CE4001S2T1B1Emerson CE4002S1T2B6

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Additional published brands

Additional Advantage Models

Tiffany verified models 016ES7515-2AN03-0AB06ES7517-3UP00-0AB06ES7518-4UP00-0AB0

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 026ES7551-1AB00-0AB06ES7553-1AA00-0AB06ED1052-1MD08-0BA2

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 036ED1052-1FB08-0BA26ES7521-7EH00-0AB06ES7414-3FM07-0AB0

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 046ES7416-3FS07-0AB06ES7654-7HB00-0XA06ES7654-7HC00-0XA0

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 05AI563AO568CD522

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 06CI541-DPCI542-DPCI592-CS31

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 07CM5640-2ETHCM582-DPCM588-CN

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 08CM589-PNIOCM598-CNDC562

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Every model above links to an existing Nordwel page. Confirm the complete model before ordering.CHECK WITH SALES

CE4001S2T2B7 Order Guide

Use the complete Emerson designation and installed hardware record for engineering review.
1Ordering identityCE4001S2T2B7
2Official evidenceEmerson DeltaV M-series Traditional I/O product data sheet
3Installation surveySeat the mass-termination connection without bent pins or displaced keying.
4Compatibility gate32 inputs
5Commissioning recordThirty-two-point schedule, mass-cable check, contact wetting review and scan test
6Substitution limitundefined

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Recent demand based on Nordwel inquiry records.
Confirm the exact part number before ordering.
SCHNEIDER ELECTRIC / OUTPUT MODULEBMXDDO1602

Output-module reference for control-system projects.

Tiffany-verified target
SCHNEIDER ELECTRIC / ETHERNET MODULEBMENOC0301

Ethernet-module reference for network compatibility review.

Tiffany-verified target
VIBRO-METER / PROXIMITY SENSORAF70982 / 111-412-000-012

Proximity-sensor reference for machinery applications.

Tiffany-verified target
VIBRO-METER / ACCELEROMETERS3960 AC46286 / 144-201-000-222

Accelerometer reference for vibration-monitoring projects.

Tiffany-verified target
WESTINGHOUSE / PROCESSOR MODULE5X00241G02

Processor-module reference for installed control systems.

Tiffany-verified target
ABB / ANALOG INPUT BOARDDSTA002B / 3BSE018317R1

Analog-input board reference for replacement review.

Tiffany-verified target
Nordwel engineering support

Company Services & FAQ

Configuration-aware support for quotation, replacement review and shipment coordination.

Support scope

Document controlUse the exact CE4001S2T2B7 source record named on this page.
Interface reviewSimplex mass termination block
Receiving checkConfirm dry-contact wiring, 32-point density and the B7 mass-termination arrangement.
Release packageThirty-two-point schedule, mass-cable check, contact wetting review and scan test

CE4001S2T2B7 FAQ

What maintenance record preserves the point density evidence for CE4001S2T2B7 32-Channel Dry-Contact Discrete Input Assembly?

Use 32 inputs as the controlled point density value in the DeltaV M-series Series 2 Plus I/O review. For motor-control status banks, reconcile all 32 dry-contact points with the marshalling schedule. Mark the evidence source and revision so future reviewers can reproduce the decision.

How does termination style limit a proposed CE4001S2T2B7 32-Channel Dry-Contact Discrete Input Assembly substitute?

Termination style is published as Simplex mass termination for the DeltaV M-series Series 2 Plus I/O. For large valve feedback groups, seat the mass-termination connection without bent pins or displaced keying. Any mismatch requires an engineering disposition rather than an undocumented field adaptation.

How can a technician test CE4001S2T2B7 32-Channel Dry-Contact Discrete Input Assembly without exceeding the stated channel count?

The official CE4001S2T2B7 record gives channel count as 32 for its 32-channel dry-contact discrete input assembly function. For packaged skid contacts, separate spare cores from active contact pairs before insulation checks. Quarantine a received unit if the label, connection, envelope or documented duty differs from the approved request.

When can the CE4001S2T2B7 32-Channel Dry-Contact Discrete Input Assembly electronics entry be released for quotation?

For this high-density dry-contact status acquisition selection, electronics is Series 2 Plus. For dense cabinet marshalling, simulate grouped and individual changes to confirm channel order. If the official record is ambiguous, omit the disputed value and request nameplate or manufacturer clarification.

How should engineers verify point density before fitting CE4001S2T2B7 32-Channel Dry-Contact Discrete Input Assembly?

Use 32 inputs as the controlled point density value in the DeltaV M-series Series 2 Plus I/O review. For motor-control status banks, reconcile all 32 dry-contact points with the marshalling schedule. The commissioning sheet should name the instrument, method, acceptance limit and approving person.

What installation decision is controlled by termination style on CE4001S2T2B7 32-Channel Dry-Contact Discrete Input Assembly?

Termination style is published as Simplex mass termination for the DeltaV M-series Series 2 Plus I/O. For large valve feedback groups, seat the mass-termination connection without bent pins or displaced keying. Use the value as a selection boundary, not as a prediction of site performance.

What commissioning check confirms the documented channel count for CE4001S2T2B7 32-Channel Dry-Contact Discrete Input Assembly?

The official CE4001S2T2B7 record gives channel count as 32 for its 32-channel dry-contact discrete input assembly function. For packaged skid contacts, separate spare cores from active contact pairs before insulation checks. Acceptance requires the documented feature to work in the installed chain without unexplained diagnostics.

At which review gate should CE4001S2T2B7 32-Channel Dry-Contact Discrete Input Assembly electronics be challenged?

For this high-density dry-contact status acquisition selection, electronics is Series 2 Plus. For dense cabinet marshalling, simulate grouped and individual changes to confirm channel order. Trace the value to the cited manufacturer source and the as-installed drawing as separate evidence items.

Which drawing or schedule should carry the CE4001S2T2B7 32-Channel Dry-Contact Discrete Input Assembly point density record?

Use 32 inputs as the controlled point density value in the DeltaV M-series Series 2 Plus I/O review. For motor-control status banks, reconcile all 32 dry-contact points with the marshalling schedule. Confirm the relevant channel, port, jaw, axis or circuit individually instead of accepting a family-level statement.

Which companion item must agree with termination style for CE4001S2T2B7 32-Channel Dry-Contact Discrete Input Assembly?

Termination style is published as Simplex mass termination for the DeltaV M-series Series 2 Plus I/O. For large valve feedback groups, seat the mass-termination connection without bent pins or displaced keying. Log the comparison against the controlled parts list before the item enters the cabinet.

Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
DeltaV M-series Series 2 Plus I/O application review

CE4001S2T2B7 Applications

These contexts use the manufacturer-documented function of CE4001S2T2B7; each requires a separate site-fit decision.

Application contexts

01 · Motor-control status banksApply the documented high-density dry-contact status acquisition only after confirming point density as 32 inputs.
02 · Large valve feedback groupsApply the documented high-density dry-contact status acquisition only after confirming contact source as Dry-contact circuits.
03 · Packaged skid contactsApply the documented high-density dry-contact status acquisition only after confirming card generation as Series 2 Plus.
04 · Dense cabinet marshallingApply the documented high-density dry-contact status acquisition only after confirming termination style as Simplex mass termination.

Why choose Nordwel

Traceable identityCE4001S2T2B7 remains the controlling ordering reference.
Official-data boundaryUnsupported ratings and option meanings are excluded.
Application-led reviewSelection is tied to high-density dry-contact status acquisition, not appearance.
Tiffany coordinationOne contact manages evidence, quotation and follow-up.
Application boundary: retain CE4001S2T2B7, Simplex mass termination block, and the approved site record as three independent checks.
Need help matching this Emerson configuration?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
Power & CommunicationIS200STAIH2ADCGE analog terminal board reference; confirm the installed I/O arrangement.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp