other
Products
6ES7414-3FM07-0AB0 CPU 414F-3 PN/DP Central Processing Unit
6ES7414-3FM07-0AB0 CPU 414F-3 PN/DP Central Processing Unit
6ES7414-3FM07-0AB0 CPU 414F-3 PN/DP Central Processing Unit

Siemens 6ES7414-3FM07-0AB0 CPU 414F-3 PN/DP Central Processing Unit

EMAIL SALES
Siemens official data reviewed
6ES7414-3FM07-0AB0 — CPU 414F-3 PN/DP Central Processing Unit

A fail-safe central processing unit with 4 MB integrated work memory and three documented interface paths for safety-related and standard automation tasks.

Siemens fail-safe central controllerFail-safe central control with integrated industrial networkingExact-order review
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
Officially reviewed product profile
Product familyFail-safe central controller
Exact model6ES7414-3FM07-0AB0
Catalog identityCPU 414F-3 PN/DP
Device baselineHardware 01 / firmware V7.0
Work memory4 MB integrated
Network arrangementMPI/DP plus two-port Ethernet/PROFINET
Rack dependencyPowered by the system supply
Verified functionSafety-related central control with integrated networking
  • Brand:

    SIEMENS
  • Item NO.:

    6ES7414-3FM07-0AB0
  • Goods Stock:

    1
  • Part Number:

    6ES7414-3FM07-0AB0
  • Description:

    A fail-safe central processing unit with 4 MB integrated work memory and three documented interface paths for safety-related and standard automation tasks.
6ES7414-3FM07-0AB0 configuration inquiry

Get a precise quote for 6ES7414-3FM07-0AB0

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

6ES7414-3FM07-0AB0 official identification

This exact article combines safety-related processing with an integrated network arrangement. The review below separates catalog ratings, rack preparation, project-fit checks and acceptance evidence so each decision has one clear source.

Procurement keyComplete article number with hardware status
Project gateRecoverable validated safety program
Installation dependencyRack power and local thermal capacity
Expansion decisionAny fitted IF 964-DP identified separately

Engineering and installation checks

  • The manufacturer identifies 6ES7414-3FM07-0AB0 as CPU 414F-3 PN/DP with 4 MB integrated work memory.
  • The CPU obtains operating power from the system power supply rather than a direct field feed.
  • Three interface paths are documented; the IF 964-DP hardware remains a separately verified plug-in item.
Official product data

6ES7414-3FM07-0AB0 key specifications

Article number 6ES7414-3FM07-0AB0
Type designation CPU 414F-3 PN/DP
Hardware status 01
Firmware V7.0
Work memory 4 MB
Program / data memory 2 MB / 2 MB
Engineering package STEP 7 V5.5 or higher with HSP 262
Supply Via system power supply
Backplane current at 5 V DC 1.3 A typical; 1.6 A maximum
Power loss 6.5 W typical
Interfaces MPI/DP; two-port Ethernet/PROFINET; plug-in IF 964-DP
Dimensions 50 × 290 × 219 mm
Weight Approx. 900 g
Operating temperature 0–60 °C

Source: Siemens official data sheet for 6ES7414-3FM07-0AB0, 27 October 2025.

Pre-order check 01

Installation environment

Plan the controller exchange around rack mechanics, system power, network segmentation and the approved safety lifecycle.

  • Confirm the 50 mm slot width, rack position and neighboring clearance before removing the installed CPU.
  • Record the system-power source and verify backplane loading against the complete rack inventory.
  • Label the MPI/DP, Ethernet and optional interface connections independently before disconnection.
  • Restore the approved safety project only after matching hardware status 01 and firmware V7.0.
Archive rack photographs, cable labels and the signed validation record with the commissioning package.
Pre-order check 02

Compatibility confirmation

Approve this CPU only after the archived project, memory demand, network layout and plug-in interface agree with the installed configuration.

Project provenance
Archived safety project tied to this article
Resource evidence
Compiled program and data use remain within their separate ceilings
Toolchain evidence
Engineering station retains the required hardware support package
Topology evidence
Every partner is assigned to its original bus segment and port
Expansion evidence
Installed plug-in module recorded by its own identity
Final selection: Apply the published ratings only to 6ES7414-3FM07-0AB0. Validate the approved safety project, hardware status and site certificates before replacement.
Recommended model families

More Siemens models

Siemens verified models 016ES7551-1AB00-0AB06ES7552-1AA00-0AB06ES7553-1AA00-0AB0

For 6ES7414-3FM07-0AB0, compare the complete article number before considering function.

Siemens verified models 026ES7505-0RB00-0AB06ED1052-1MD08-0BA26ED1052-1FB08-0BA2

For 6ES7414-3FM07-0AB0, confirm the installed rack position and available width.

Siemens verified models 036ED1052-1HB08-0BA26ES7515-2RN03-0AB06ES7518-4JP00-0AB0

For 6ES7414-3FM07-0AB0, review connector keying before any cable is transferred.

Siemens verified models 046ES7521-1FH00-0AA06ES7521-7EH00-0AB06ES7522-5EH00-0AB0

For 6ES7414-3FM07-0AB0, retain the original terminal schedule during removal.

Additional published brands

Additional Advantage Models

Tiffany verified models 01PM5012-R-ETHPM5052-T-ETHPM5630-2ETH

For 6ES7414-3FM07-0AB0, separate power-feed requirements from signal-interface checks.

Tiffany verified models 02PM5650-2ETHPM5670-2ETHPM571-ETH

For 6ES7414-3FM07-0AB0, record the approved firmware baseline before shutdown.

Tiffany verified models 03PM582-ETHSM560-S-FD-1SM560-S-FD-4

For 6ES7414-3FM07-0AB0, check enclosure temperature and airflow at the actual mounting point.

Tiffany verified models 04DO524DO562ATV320U75N4B

For 6ES7414-3FM07-0AB0, match communication roles to the project topology.

Tiffany verified models 05AI523AI531AI562

For 6ES7414-3FM07-0AB0, preserve protective-device and grounding records.

Tiffany verified models 06CM577-ETHTU531TU532

For 6ES7414-3FM07-0AB0, verify memory and program capacity against the archived project.

Tiffany verified models 07CI862K01TP831DP865

For 6ES7414-3FM07-0AB0, inspect mating plugs for damage and coding differences.

Tiffany verified models 08TU835TU836TU837

For 6ES7414-3FM07-0AB0, confirm every optional interface as a separately controlled item.

Every model above links to an existing Nordwel page. Confirm the complete model before ordering.CHECK WITH SALES

6ES7414-3FM07-0AB0 Order Guide

Use the complete Siemens designation and installed hardware record for engineering review.
1Article lockEnter 6ES7414-3FM07-0AB0 exactly, including every hyphen and suffix group.
2Archive packageAttach the latest recoverable project and its change-control reference.
3Installed snapshotAdd photographs of labels, rack position and fitted accessories.
4Outage sequenceDefine cable transfer, project restore and rollback checkpoints.
5Receiving criteriaState which markings and included items must be inspected on arrival.
6Validation ownerName the person authorized to execute and sign the safety acceptance plan.

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Recent demand based on Nordwel inquiry records.
Confirm the exact part number before ordering.
SCHNEIDER ELECTRIC / OUTPUT MODULEBMXDDO1602

Output-module reference for control-system projects.

Tiffany-verified target
SCHNEIDER ELECTRIC / ETHERNET MODULEBMENOC0301

Ethernet-module reference for network compatibility review.

Tiffany-verified target
VIBRO-METER / PROXIMITY SENSORAF70982 / 111-412-000-012

Proximity-sensor reference for machinery applications.

Tiffany-verified target
VIBRO-METER / ACCELEROMETERS3960 AC46286 / 144-201-000-222

Accelerometer reference for vibration-monitoring projects.

Tiffany-verified target
WESTINGHOUSE / PROCESSOR MODULE5X00241G02

Processor-module reference for installed control systems.

Tiffany-verified target
ABB / ANALOG INPUT BOARDDSTA002B / 3BSE018317R1

Analog-input board reference for replacement review.

Tiffany-verified target
Nordwel engineering support

Company Services & FAQ

Support for memory matching, firmware control, network mapping and safe quotation handoff for this exact CPU.

Support scope

Archive readinessConfirm that restoration media, passwords and change history are available before the outage.
Cabinet surveyConvert photographs and measurements into an installation checklist for the exact rack position.
Cutover worksheetSequence every disconnect and reconnect action with an accountable checker.
Release dossierAssemble diagnostic, functional and approval records for the production handback.

6ES7414-3FM07-0AB0 FAQ

How should the published memory split be checked without repeating catalog values?

Use the two memory rows in the specification table as ceilings, then attach a compiler report that shows actual program and data consumption separately.

What rack-power evidence is needed before exchange?

Provide the installed power-supply identity, the complete module inventory and the documented load calculation for the occupied rack.

How should the three communication paths be handled during cutover?

Assign a cable label, network role, address record and restore checkpoint to each physical path before any connector is moved.

Why is the engineering support package part of compatibility?

The station must recognize the exact hardware catalog entry. Archive the working configuration environment with the project rather than assuming a newer workstation is sufficient.

What prevents restoration to the wrong device revision?

Match the received label to the published baseline in the table, preserve the as-found record and require a controlled review before downloading the project.

How should cabinet fit be evaluated?

Use the dimensional row as the device envelope, then add site-specific front access, cable bend, neighboring-module and service-clearance requirements.

Where should temperature be measured?

Measure inside the enclosure at the controller position under representative load; room temperature alone does not describe the local thermal condition.

How is an optional interface treated in the inquiry?

List it as a separate installed item with its own article number and photographs; an available plug-in position does not prove the hardware is fitted.

Which records make the quotation technically actionable?

Send identity photographs, quantity, destination, project revision, rack inventory, accessory list and the planned outage window.

What closes the replacement activity?

A designated approver should sign the diagnostic, communications and safety-function results defined in the site acceptance procedure.

Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
Siemens fail-safe central controller application review

6ES7414-3FM07-0AB0 Applications

Four distinct engineering contexts for a CPU whose exact hardware, firmware and validated project must remain coordinated.

Application contexts

01 · Safety-related process sequence controlUse the 4 MB controller where the validated safety program and execution demand fit the documented capacity.
02 · Combined standard and fail-safe logicKeep ordinary control tasks and safety functions separated by the approved engineering and validation rules.
03 · Distributed I/O coordinationMap each DP and Ethernet device to the archived topology before recreating communications.
04 · High-availability maintenance planningPrepare rollback media, rack records and test ownership before the planned controller outage.

Why choose Nordwel

Evidence-ready inquiryA single request can carry identity, rack context and project ownership without mixing their sources.
Receiving disciplineInspection criteria are defined before the unit reaches the cabinet.
Port-by-port cutoverCable moves can be scheduled and checked independently during the outage.
Review coordinationTiffany Guan can consolidate the submitted records into one technical handoff.
Selection boundary: memory size, firmware, interfaces and safety validation must all match the controlled project record.
Need a configuration review for this 4 MB fail-safe CPU?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
Power & CommunicationIS200STAIH2ADCGE analog terminal board reference; confirm the installed I/O arrangement.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp