other
Products
VE4026 M-series Virtual I/O Module 2
VE4026 M-series Virtual I/O Module 2
VE4026 M-series Virtual I/O Module 2

Emerson VE4026 M-series Virtual I/O Module 2

EMAIL SALES
Emerson official data reviewed
VE4026 — M-series Virtual I/O Module 2

A single M-series VIM2 used for licensed Ethernet I/O drivers, Railbus integration or process simulation.

DeltaV M-series VIM2Single-module Ethernet I/O and simulation interfaceExact-order review
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
Officially reviewed product profile
ManufacturerEmerson
Documented familyDeltaV M-series VIM2
Product formM-series Virtual I/O Module 2
Primary functionSingle-module Ethernet I/O and simulation interface
Module typeM-series VIM2
Operating formSingle module
Required carrierOne power/controller carrier
Required supplyOne dedicated system power supply
  • Brand:

    Emerson
  • Item NO.:

    VE4026
  • Goods Stock:

    1
  • Part Number:

    VE4026
  • Description:

    A single M-series VIM2 used for licensed Ethernet I/O drivers, Railbus integration or process simulation.
VE4026 configuration inquiry

Get a precise quote for VE4026

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

VE4026 official identification

A single M-series VIM2 used for licensed Ethernet I/O drivers, Railbus integration or process simulation.

System roleSingle-module Ethernet I/O and simulation interface
Connection boundaryVIM2 on a dedicated power/controller carrier
Selection focusConfirm the exact driver, dedicated power architecture, carrier position and license scope.
Release evidenceModule label, driver license, converted configuration and mapped-I/O validation

Engineering and installation checks

  • undefined
  • Reserve the dedicated carrier position and power supply before installation.
  • Manufacturer verification basis: Emerson DeltaV M-series Virtual I/O Module 2 product data sheet.
Official product data

VE4026 key specifications

Module type M-series VIM2
Operating form Single module
Required carrier One power/controller carrier
Required supply One dedicated system power supply
Ethernet I/O driver Purchased separately
Legacy VIM driver Not directly reusable
Simulation prerequisites Mimic plus Railbus Driver
License boundary Per operating VIM

Source: Emerson DeltaV M-series Virtual I/O Module 2 product data sheet.

Pre-order check 01

Installation environment

Review the physical, electrical and environmental conditions that control installation of VE4026.

  • Reserve the dedicated carrier position and power supply before installation.
  • Convert any legacy VIM driver configuration before loading it to VIM2.
  • Document network addressing, driver package and I/O map.
  • Prove data quality, update behavior and diagnostics at each mapped endpoint.
Record the as-found condition and the final module label, driver license, converted configuration and mapped-i/o validation
Pre-order check 02

Compatibility confirmation

Close each documented selection boundary for VE4026 before purchase approval.

Physical replacement
VIM can be physically replaced, but function is not drop-in
Driver conversion
Required for legacy VIM drivers
Power boundary
Dedicated system supply
License boundary
Driver licensed for this operating VIM
Application
Ethernet I/O integration or licensed simulation
Final selection: Use only the values published for VE4026 in Emerson DeltaV M-series Virtual I/O Module 2 product data sheet; site suitability remains an engineering decision.
Recommended model families

More Emerson models

Emerson verified models 01Emerson PR6423/000-010 CON021Emerson KJ3241X1-BA1 12P2506X042Emerson A6210

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Emerson verified models 02Emerson KJ3002X1-BG2 12P1731X082 VE4003S5B1Emerson WH5D-2FF 1X00416H03Emerson A6510 A6510-T

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Emerson verified models 03Emerson A6120Emerson KJ3222X1-BA1 12P2532X122 VE4003S2B2Emerson KJ2101X1-BA1 12P2690X012

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Emerson verified models 04Emerson KJ3001X1-BG1 12P0557X162 VE4002S1T1B1Emerson PR6424/000-040 CON021Emerson KJ1501X1-BB1 12P0678X032

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Additional published brands

Additional Advantage Models

Tiffany verified models 016ES7414-2XG02-0AB06ES7416-2XL01-0AB06ES7425-2AD00-0AA0

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 026ES7515-2AN03-0AB06ES7517-3UP00-0AB06ES7518-4UP00-0AB0

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 036ES7551-1AB00-0AB06ES7553-1AA00-0AB06ED1052-1MD08-0BA2

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 046ED1052-1FB08-0BA26ES7521-7EH00-0AB06ES7414-3FM07-0AB0

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 056ES7416-3FS07-0AB06ES7654-7HB00-0XA06ES7654-7HC00-0XA0

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 06AI563AO568CD522

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 07CI541-DPCI542-DPCI592-CS31

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 08CM5640-2ETHCM582-DPCM588-CN

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Every model above links to an existing Nordwel page. Confirm the complete model before ordering.CHECK WITH SALES

VE4026 Order Guide

Use the complete Emerson designation and installed hardware record for engineering review.
1Ordering identityVE4026
2Official evidenceEmerson DeltaV M-series Virtual I/O Module 2 product data sheet
3Installation surveyConvert any legacy VIM driver configuration before loading it to VIM2.
4Compatibility gateVIM can be physically replaced, but function is not drop-in
5Commissioning recordModule label, driver license, converted configuration and mapped-I/O validation
6Substitution limitundefined

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Recent demand based on Nordwel inquiry records.
Confirm the exact part number before ordering.
SCHNEIDER ELECTRIC / OUTPUT MODULEBMXDDO1602

Output-module reference for control-system projects.

Tiffany-verified target
SCHNEIDER ELECTRIC / ETHERNET MODULEBMENOC0301

Ethernet-module reference for network compatibility review.

Tiffany-verified target
VIBRO-METER / PROXIMITY SENSORAF70982 / 111-412-000-012

Proximity-sensor reference for machinery applications.

Tiffany-verified target
VIBRO-METER / ACCELEROMETERS3960 AC46286 / 144-201-000-222

Accelerometer reference for vibration-monitoring projects.

Tiffany-verified target
WESTINGHOUSE / PROCESSOR MODULE5X00241G02

Processor-module reference for installed control systems.

Tiffany-verified target
ABB / ANALOG INPUT BOARDDSTA002B / 3BSE018317R1

Analog-input board reference for replacement review.

Tiffany-verified target
Nordwel engineering support

Company Services & FAQ

Configuration-aware support for quotation, replacement review and shipment coordination.

Support scope

Document controlUse the exact VE4026 source record named on this page.
Interface reviewVIM2 on a dedicated power/controller carrier
Receiving checkConfirm the exact driver, dedicated power architecture, carrier position and license scope.
Release packageModule label, driver license, converted configuration and mapped-I/O validation

VE4026 FAQ

When can the VE4026 M-series Virtual I/O Module 2 operating form entry be released for quotation?

For this single-module ethernet i/o and simulation interface selection, operating form is Single module. For single ethernet i/o gateway, reserve the dedicated carrier position and power supply before installation. The purchase description must retain units, polarity, wiring form and option wording exactly where they are published.

How should engineers verify ethernet i/o driver before fitting VE4026 M-series Virtual I/O Module 2?

Use Purchased separately as the controlled ethernet i/o driver value in the DeltaV M-series VIM2 review. For process simulation interface, convert any legacy VIM driver configuration before loading it to VIM2. Use a calibrated observation where measurement is possible and attach the result to receiving inspection.

What installation decision is controlled by license boundary on VE4026 M-series Virtual I/O Module 2?

License boundary is published as Per operating VIM for the DeltaV M-series VIM2. For railbus driver host, document network addressing, driver package and I/O map. Record the complete marking in focus; cropped labels are not sufficient for exact-order approval.

What commissioning check confirms the documented power boundary for VE4026 M-series Virtual I/O Module 2?

The official VE4026 record gives power boundary as Dedicated system supply for its m-series virtual i/o module 2 function. For legacy vim modernization, prove data quality, update behavior and diagnostics at each mapped endpoint. Test at a safe initial condition, then progress to the operating point defined by the approved procedure.

At which review gate should VE4026 M-series Virtual I/O Module 2 module type be challenged?

For this single-module ethernet i/o and simulation interface selection, module type is M-series VIM2. For single ethernet i/o gateway, reserve the dedicated carrier position and power supply before installation. Do not translate a nearby suffix, catalog family or distributor description into an exact-model claim.

Which drawing or schedule should carry the VE4026 M-series Virtual I/O Module 2 required supply record?

Use One dedicated system power supply as the controlled required supply value in the DeltaV M-series VIM2 review. For process simulation interface, convert any legacy VIM driver configuration before loading it to VIM2. Release is appropriate only when the manufacturer value and the project requirement agree.

Which companion item must agree with simulation prerequisites for VE4026 M-series Virtual I/O Module 2?

Simulation prerequisites is published as Mimic plus Railbus Driver for the DeltaV M-series VIM2. For railbus driver host, document network addressing, driver package and I/O map. A substitution review must close functional, mechanical, electrical and environmental differences independently.

How should a discrepancy in driver conversion be closed for VE4026 M-series Virtual I/O Module 2?

The official VE4026 record gives driver conversion as Required for legacy VIM drivers for its m-series virtual i/o module 2 function. For legacy vim modernization, prove data quality, update behavior and diagnostics at each mapped endpoint. Keep the old and replacement assemblies available for a side-by-side check until the acceptance record is signed.

What receiving evidence is required for the application stated for VE4026 M-series Virtual I/O Module 2?

For this single-module ethernet i/o and simulation interface selection, application is Ethernet I/O integration or licensed simulation. For single ethernet i/o gateway, reserve the dedicated carrier position and power supply before installation. Preserve both the as-found condition and the final test so the next maintenance action starts from verified evidence.

How is required carrier separated from site-specific assumptions for VE4026 M-series Virtual I/O Module 2?

Use One power/controller carrier as the controlled required carrier value in the DeltaV M-series VIM2 review. For process simulation interface, convert any legacy VIM driver configuration before loading it to VIM2. Mark the evidence source and revision so future reviewers can reproduce the decision.

Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
DeltaV M-series VIM2 application review

VE4026 Applications

These contexts use the manufacturer-documented function of VE4026; each requires a separate site-fit decision.

Application contexts

01 · Single Ethernet I/O gatewayApply the documented single-module ethernet i/o and simulation interface only after confirming physical replacement as VIM can be physically replaced, but function is not drop-in.
02 · Process simulation interfaceApply the documented single-module ethernet i/o and simulation interface only after confirming driver conversion as Required for legacy VIM drivers.
03 · Railbus driver hostApply the documented single-module ethernet i/o and simulation interface only after confirming power boundary as Dedicated system supply.
04 · Legacy VIM modernizationApply the documented single-module ethernet i/o and simulation interface only after confirming license boundary as Driver licensed for this operating VIM.

Why choose Nordwel

Traceable identityVE4026 remains the controlling ordering reference.
Official-data boundaryUnsupported ratings and option meanings are excluded.
Application-led reviewSelection is tied to single-module ethernet i/o and simulation interface, not appearance.
Tiffany coordinationOne contact manages evidence, quotation and follow-up.
Application boundary: retain VE4026, VIM2 on a dedicated power/controller carrier, and the approved site record as three independent checks.
Need help matching this Emerson configuration?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
Power & CommunicationIS200STAIH2ADCGE analog terminal board reference; confirm the installed I/O arrangement.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp