A legacy MIV II digital voltage and frequency protection relay whose complete code selects the MIV II 3000 function set, 10–250 V input, English interface, HI auxiliary supply and no conformal coating.
Brand:
General ElectricItem NO.:
MIVII3000E00HI00Part Number:
MIVII3000E00HI00Weight:
See nameplate and packageDimensions:
Quarter 19-inch rack, 4UCertification:
UL 508 / CNL C22.2; IP52 enclosureDescription:
A legacy MIV II digital voltage and frequency protection relay whose complete code selects the MIV II 3000 function set, 10–250 V input, English interface, HI auxiliary supply and no conformal coating.GE Vernova identifies MIVII3000E00HI00 as MIV II voltage and frequency protection relay. A legacy MIV II digital voltage and frequency protection relay whose complete code selects the MIV II 3000 function set, 10–250 V input, English interface, HI auxiliary supply and no conformal coating.
Published controller, communication and remote-I/O products with verified contacts.
Verified protection, monitoring, vibration and thrust-measurement products.
Published proximity, velocity and speed-sensing options.
Verified analog, digital and compact signal-board products.
Verified Siemens analog-input, analog-output and temperature-measurement modules.
Verified S7-200 SMART CPUs, communication boards and compact digital I/O.
Published 8 mm and NSv proximity probe configurations.
Verified 5 mm, 11 mm, 25 mm, 50 mm and ceramic-capped probe options.
Verified probe housings, mounting studs and system cable accessories.
Published velocity, thrust, speed and vibration-sensing products.
Verified protection relays, controllers and machinery-monitoring products.
Additional verified automation, monitoring and I/O products published on Nordwel.
Use the exact manufacturer order number and verify the system constraints before procurement.
Match every character of MIVII3000E00HI00 to the relay nameplate and quotation.
Validate that voltage protection plus two frequency elements matches the scheme.
Use the 10–250 V range selected by code 0.
Confirm the site supply fits the HI AC or DC range.
The final 0 specifies no conformal coating; compare the cabinet environment with the published limits.
Decide whether the project needs an exact MIV II spare or evaluation of P94V / 350 alternatives.
Selected specialist-brand products requested for regional projects and available on Nordwel.
Auxiliary relay option for protection and control applications.
Recent Middle East inquirySIMATIC S7-200 SMART RS485 communication board.
Recent Middle East inquiryRemote I/O gateway for demanding process-system environments.
Specialist brandReplacement inverter driver board for installed industrial systems.
Specialist brandAmplifier transducer for load-cell signal conditioning.
Specialist brandIndustrial power-supply model for legacy equipment support.
Specialist brandAnswers below use GE Vernova official product documentation for this exact order number.
It is an MIV II legacy digital relay combining voltage protection with two frequency elements.
The official ordering table identifies 3000 as voltage protection plus two frequency elements.
It selects a 10 to 250 V input range.
E selects the English-language interface.
HI accepts 110–250 V DC within 88–300 V DC, or 110–230 V AC within 88–264 V AC at 48–62 Hz.
No. The final 0 identifies the version without conformal coating.
The manual lists front RS232 and rear RS485 with Modbus RTU up to 19.2 kbit/s.
No. GE Vernova marks MIV II manufacturing discontinued and lists P94V and 350 relays as alternatives.
Software, licensing, controller, interface, shield and power-supply references.
Internal cable references for 40-channel input and output connections to field termination assemblies.
I/O Companion Slot to FTA · 2.5 m
I/O Companion Slot to FTA · 4.5 m
I/O Companion Slot to FTA · 6.5 m
I/O Companion Slot to FTA · 8.5 m
I/O Companion Slot to FTA · 10.5 m
I/O Companion Slot to FTA · 12.5 m
I/O Companion Slot to FTA · 4.5 m
I/O Companion Slot to FTA · 6.5 m
I/O Companion Slot to FTA · 8.5 m
Use the verified electrical, lifecycle and system limits—not generic family assumptions—to decide suitability.
Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.
Related Tags :