other
Products
TK-OAH061 Six-Point Analog Output Module
TK-OAH061 Six-Point Analog Output Module
TK-OAH061 Six-Point Analog Output Module

Honeywell TK-OAH061 Six-Point Analog Output Module

EMAIL SALES
Honeywell official data reviewed
TK-OAH061 — Six-Point Analog Output Module

TK-OAH061 is the Honeywell-listed coated six-point analog output module for 4–20 mA current loops.

Honeywell Legacy Process I/OSix-channel 4–20 mA analog command outputExact-order review
Sales managerTiffany Guan
Mobile / WhatsApp+86 18030235313
Officially reviewed product profile
ManufacturerHoneywell
Documented familyHoneywell Legacy Process I/O
Product formSix-Point Analog Output Module
Primary functionSix-channel 4–20 mA analog command output
Exact designationTK-OAH061
Output points6
Output signal4–20 mA
Conformal coatingYes
  • Brand:

    Honeywell
  • Item NO.:

    TK-OAH061
  • Goods Stock:

    1
  • Part Number:

    TK-OAH061
  • Description:

    TK-OAH061 is the Honeywell-listed coated six-point analog output module for 4–20 mA current loops.
TK-OAH061 configuration inquiry

Get a precise quote for TK-OAH061

Email Sales
Sales managerTiffany Guan
WhatsApp+86 18030235313

TK-OAH061 official identification

TK-OAH061 is the Honeywell-listed coated six-point analog output module for 4–20 mA current loops.

System roleSix-channel 4–20 mA analog command output
Connection boundary6 analog outputs at 4–20 mA
Selection focusConfirm six output loops, 4–20 mA receiving loads, coating requirement and point-to-terminal mapping.
Release evidenceTK-OAH061 label, six-loop schedule, load-resistance review, current-ramp test and final command record

Engineering and installation checks

  • undefined
  • Isolate every driven device before moving the six current-output conductors.
  • Manufacturer verification basis: Honeywell November 2020 System HINTS — legacy module identification.
Official product data

TK-OAH061 key specifications

Exact designation TK-OAH061
Output points 6
Output signal 4–20 mA
Conformal coating Yes
Signal direction Analog output

Source: Honeywell November 2020 System HINTS — legacy module identification.

Pre-order check 01

Installation environment

Review the physical, electrical and environmental conditions that control installation of TK-OAH061.

  • Isolate every driven device before moving the six current-output conductors.
  • Record polarity and receiving load for each 4–20 mA loop.
  • Inspect the coated board and connector edges before seating the module.
  • Ramp each output through controlled values and compare the field response with the command.
Record the as-found condition and the final tk-oah061 label, six-loop schedule, load-resistance review, current-ramp test and final command record
Pre-order check 02

Compatibility confirmation

Close each documented selection boundary for TK-OAH061 before purchase approval.

Output count
6
Current range
4–20 mA
Signal direction
Output
Environmental option
Coated module
Field receiver
Match the installed current-loop load
Final selection: Use only the values published for TK-OAH061 in Honeywell November 2020 System HINTS — legacy module identification; site suitability remains an engineering decision.
Recommended model families

More Honeywell models

Honeywell verified models 01Honeywell CC-GDOL21Honeywell CC-TSP411 51306669-175Honeywell FC-TCNT11 51307928-176

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Honeywell verified models 02Honeywell 10014/I/FHoneywell FC-IOTA-NR24 51306507-175Honeywell FC-SCNTO2

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Honeywell verified models 03Honeywell FC-TSDO-04UNIHoneywell FS-TSDO-04UNIHoneywell FS-TSDO-0824

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Honeywell verified models 04Honeywell FS-TSRO-0824Honeywell FS-TSAI-1620MHoneywell FS-TSGAS-1624

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Additional published brands

Additional Advantage Models

Tiffany verified models 01ABB NTR012-AABB NDBU-95 64008366DABB RAI02J

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 02ABB PFEA113 3BSE028144R0020ABB 3BHE037649R0101 PDD500A101ABB 3BHE019633R0101 PDD200A101

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 03ABB 3BHE015619R0001 XVD825A01ABB DSTA002B 3BSE018317R1Schneider PN072132P902 / 3D658187G901

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 04Schneider BMXDDO1602Schneider BMENOC0301GE SST-PFB3-VME2

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 05Woodhead SST-DNP-PCI-4Vibro-Meter AF70982 / 111-412-000-012Vibro-Meter S3960 AC46286 / 144-201-000-222

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 06Westinghouse 5X00241G02Westinghouse 5X00058G01Westinghouse 5X00226G01

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 07AREVA MVAJ101RA0802ABently Nevada 21505-00-28-05-02Pepperl+Fuchs RSD-GW3-Ex2.DPE

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Tiffany verified models 08Load Cell Central OM-19-2Schneider AP4423ABB 086364-001

Each target page displays Tiffany Guan and sales2@mooreplc.com.

Every model above links to an existing Nordwel page. Confirm the complete model before ordering.CHECK WITH SALES

TK-OAH061 Order Guide

Use the complete Honeywell designation and installed hardware record for engineering review.
1Ordering identityTK-OAH061
2Official evidenceHoneywell November 2020 System HINTS — legacy module identification
3Installation surveyRecord polarity and receiving load for each 4–20 mA loop.
4Compatibility gate6
5Commissioning recordTK-OAH061 label, six-loop schedule, load-resistance review, current-ramp test and final command record
6Substitution limitundefined

Middle East Demand & Specialist Models

Selected specialist-brand products requested for regional projects and available on Nordwel.

Recent demand based on Nordwel inquiry records.
Confirm the exact part number before ordering.
SCHNEIDER ELECTRIC / OUTPUT MODULEBMXDDO1602

Output-module reference for control-system projects.

Tiffany-verified target
SCHNEIDER ELECTRIC / ETHERNET MODULEBMENOC0301

Ethernet-module reference for network compatibility review.

Tiffany-verified target
VIBRO-METER / PROXIMITY SENSORAF70982 / 111-412-000-012

Proximity-sensor reference for machinery applications.

Tiffany-verified target
VIBRO-METER / ACCELEROMETERS3960 AC46286 / 144-201-000-222

Accelerometer reference for vibration-monitoring projects.

Tiffany-verified target
WESTINGHOUSE / PROCESSOR MODULE5X00241G02

Processor-module reference for installed control systems.

Tiffany-verified target
ABB / ANALOG INPUT BOARDDSTA002B / 3BSE018317R1

Analog-input board reference for replacement review.

Tiffany-verified target
Nordwel engineering support

Company Services & FAQ

Configuration-aware support for quotation, replacement review and shipment coordination.

Support scope

Document controlUse the exact TK-OAH061 source record named on this page.
Interface review6 analog outputs at 4–20 mA
Receiving checkConfirm six output loops, 4–20 mA receiving loads, coating requirement and point-to-terminal mapping.
Release packageTK-OAH061 label, six-loop schedule, load-resistance review, current-ramp test and final command record

TK-OAH061 FAQ

Why does field receiver matter when selecting TK-OAH061 Six-Point Analog Output Module in the six-loop command verification record?

The official TK-OAH061 record gives field receiver as Match the installed current-loop load for its six-point analog output module function. For valve command loops, isolate every driven device before moving the six current-output conductors. Acceptance requires the documented feature to work in the installed chain without unexplained diagnostics. File this as six-loop command verification checkpoint 1; do not reuse the result for another model or channel group.

Which mismatch involving output signal should stop approval of TK-OAH061 Six-Point Analog Output Module in the six-loop command verification record?

For this six-channel 4–20 ma analog command output selection, output signal is 4–20 mA. For six-channel actuator control, record polarity and receiving load for each 4–20 mA loop. Trace the value to the cited manufacturer source and the as-installed drawing as separate evidence items. File this as six-loop command verification checkpoint 2; do not reuse the result for another model or channel group.

What maintenance record preserves the output count evidence for TK-OAH061 Six-Point Analog Output Module in the six-loop command verification record?

Use 6 as the controlled output count value in the Honeywell Legacy Process I/O review. For current-output restoration, inspect the coated board and connector edges before seating the module. Confirm the relevant channel, port, jaw, axis or circuit individually instead of accepting a family-level statement. File this as six-loop command verification checkpoint 3; do not reuse the result for another model or channel group.

How does environmental option limit a proposed TK-OAH061 Six-Point Analog Output Module substitute in the six-loop command verification record?

Environmental option is published as Coated module for the Honeywell Legacy Process I/O. For coated output cabinet service, ramp each output through controlled values and compare the field response with the command. Log the comparison against the controlled parts list before the item enters the cabinet. File this as six-loop command verification checkpoint 4; do not reuse the result for another model or channel group.

How can a technician test TK-OAH061 Six-Point Analog Output Module without exceeding the stated output points in the six-loop command verification record?

The official TK-OAH061 record gives output points as 6 for its six-point analog output module function. For valve command loops, isolate every driven device before moving the six current-output conductors. Check the mating device, protective hardware and configured function before energization. File this as six-loop command verification checkpoint 5; do not reuse the result for another model or channel group.

When can the TK-OAH061 Six-Point Analog Output Module signal direction entry be released for quotation in the six-loop command verification record?

For this six-channel 4–20 ma analog command output selection, signal direction is Analog output. For six-channel actuator control, record polarity and receiving load for each 4–20 mA loop. The purchase description must retain units, polarity, wiring form and option wording exactly where they are published. File this as six-loop command verification checkpoint 6; do not reuse the result for another model or channel group.

How should engineers verify signal direction before fitting TK-OAH061 Six-Point Analog Output Module in the six-loop command verification record?

Use Output as the controlled signal direction value in the Honeywell Legacy Process I/O review. For current-output restoration, inspect the coated board and connector edges before seating the module. Use a calibrated observation where measurement is possible and attach the result to receiving inspection. File this as six-loop command verification checkpoint 7; do not reuse the result for another model or channel group.

What installation decision is controlled by exact designation on TK-OAH061 Six-Point Analog Output Module in the six-loop command verification record?

Exact designation is published as TK-OAH061 for the Honeywell Legacy Process I/O. For coated output cabinet service, ramp each output through controlled values and compare the field response with the command. Record the complete marking in focus; cropped labels are not sufficient for exact-order approval. File this as six-loop command verification checkpoint 8; do not reuse the result for another model or channel group.

What commissioning check confirms the documented conformal coating for TK-OAH061 Six-Point Analog Output Module in the six-loop command verification record?

The official TK-OAH061 record gives conformal coating as Yes for its six-point analog output module function. For valve command loops, isolate every driven device before moving the six current-output conductors. Test at a safe initial condition, then progress to the operating point defined by the approved procedure. File this as six-loop command verification checkpoint 9; do not reuse the result for another model or channel group.

At which review gate should TK-OAH061 Six-Point Analog Output Module current range be challenged in the six-loop command verification record?

For this six-channel 4–20 ma analog command output selection, current range is 4–20 mA. For six-channel actuator control, record polarity and receiving load for each 4–20 mA loop. Do not translate a nearby suffix, catalog family or distributor description into an exact-model claim. File this as six-loop command verification checkpoint 10; do not reuse the result for another model or channel group.

Sales managerTiffany Guan
WhatsApp+86 18030235313
ICS TRIPLEX / TRUSTED

Trusted T8000 Series Model Directory

Software, licensing, controller, interface, shield and power-supply references.

Software & Licensing

T8013SOE & Process Historian Software Package
T8017Peer to Peer Communications Software Package
T8019Process Control Algorithm Software Package
T8030SOPC Server Package
T8082DIEC1131 Toolset Suite; Licensed to Hard Drive
T8082UIEC1131 Toolset Suite; USB Port Dongle
T8090MLicense for SIS Workstation 1.0 MED

Controller, Interface & Power Modules

T8100CController Chassis Module
T8111CProcessor Module
T8120CProcessor Interface Adaptor Module
T8121CProcessor Interface Adaptor Module (IRIG-B)
T8122CProcessor Interface Adaptor Module (MODBUS Master)
T8123CProcessor Interface Adaptor Module (IRIG-B and MODBUS Master)
T8151CCommunication Interface Module

Communication Adaptors, Shield & Power Modules

T8153CCommunication Interface Adaptor Module
T8191Shield Module
T8193Shield Module
T8231Power Supply Module
Exact-match links open existing Nordwel product pages. Reference-only models remain unlinked until a matching product page is published.
ICS TRIPLEX / I/O CABLES

Companion-Slot to FTA Cable Selection

Internal cable references for 40-channel input and output connections to field termination assemblies.

INPUT · 40 CHANNEL
TC-201-02-2M5

I/O Companion Slot to FTA · 2.5 m

INPUT · 40 CHANNEL
TC-201-02-4M5

I/O Companion Slot to FTA · 4.5 m

INPUT · 40 CHANNEL
TC-201-02-6M5

I/O Companion Slot to FTA · 6.5 m

INPUT · 40 CHANNEL
TC-201-02-8M5

I/O Companion Slot to FTA · 8.5 m

INPUT · 40 CHANNEL
TC-201-02-10M5

I/O Companion Slot to FTA · 10.5 m

INPUT · 40 CHANNEL
TC-201-02-12M5

I/O Companion Slot to FTA · 12.5 m

OUTPUT · 40 CHANNEL
TC-205-02-4M5

I/O Companion Slot to FTA · 4.5 m

OUTPUT · 40 CHANNEL
TC-205-02-6M5

I/O Companion Slot to FTA · 6.5 m

OUTPUT · 40 CHANNEL
TC-205-02-8M5

I/O Companion Slot to FTA · 8.5 m

Exact-match links open existing Nordwel product pages. Confirm channel direction, cable length and FTA compatibility before quotation.
Honeywell Legacy Process I/O application review

TK-OAH061 Applications

These contexts use the manufacturer-documented function of TK-OAH061; each requires a separate site-fit decision.

Application contexts

01 · Valve command loopsApply the documented six-channel 4–20 ma analog command output only after confirming output count as 6.
02 · Six-channel actuator controlApply the documented six-channel 4–20 ma analog command output only after confirming current range as 4–20 mA.
03 · Current-output restorationApply the documented six-channel 4–20 ma analog command output only after confirming signal direction as Output.
04 · Coated output cabinet serviceApply the documented six-channel 4–20 ma analog command output only after confirming environmental option as Coated module.

Why choose Nordwel

Traceable identityTK-OAH061 remains the controlling ordering reference.
Official-data boundaryUnsupported ratings and option meanings are excluded.
Application-led reviewSelection is tied to six-channel 4–20 ma analog command output, not appearance.
Tiffany coordinationOne contact manages evidence, quotation and follow-up.
Application boundary: retain TK-OAH061, 6 analog outputs at 4–20 mA, and the approved site record as three independent checks.
Need help matching this Honeywell configuration?CONTACT SALES
Need a hard-to-find industrial spare?Send the complete model, manufacturer, quantity and equipment nameplate. Nordwel will cross-check the exact brand, revision, electrical interface and mechanical configuration before quotation.
CROSS-BRAND MODEL SUPPORT

Industrial Spare Parts Reference

Selected legacy and specialist models for motion, sensing, pneumatic and control-system applications.

Motion & DrivesBLS3-4 BLS3Legacy servo/control unit; confirm the full BLS3 designation.
Pneumatic & Process2000018 KA12A10A0 11180747BEKO/BEKOMAT condensate-drain component reference.
Sensors & MeasurementMS2712RZero-speed monitoring device; verify supply and revision.
Motion & DrivesAE100M 200-00182Rotary encoder reference; confirm interface and mounting.
Sensors & MeasurementSFET-F500-L-W18-B-K1Configured industrial sensor assembly; verify the full option string.
Pneumatic & ProcessTZ2LE024PGVAB 074308Configured valve component; confirm coil voltage and port options.
Power & CommunicationIS200STAIH2ADCGE analog terminal board reference; confirm the installed I/O arrangement.
Motion & DrivesMDX60A0110503400 8226857SEW-EURODRIVE MOVIDRIVE inverter reference.
Sensors & MeasurementPTP35A2A13P1PH4AConfigured process-instrument reference; verify range and output.
Power & CommunicationHITACHI 33016136-5Hitachi industrial control spare; confirm the host equipment family.
Pneumatic & ProcessNUMATICS 34203626Numatics pneumatic component; verify valve and coil configuration.
Sensors & MeasurementHBM WA/20mm 050310129 090610052HBM displacement transducer with 20 mm measurement reference.
Pneumatic & ProcessFESTO 184518 DPA-63-10Festo twin-piston pneumatic pressure booster.
Power & CommunicationH920Legacy industrial control spare; nameplate confirmation required.
Sensors & MeasurementPN3093ifm electronic pressure sensor with digital display.
Power & CommunicationK2001000100MConfigured cable or assembly reference; confirm the equipment family.
Power & CommunicationPCD3W800Saia PCD3 analog I/O module reference.
Motion & Drives49/F2-10 P 80 B14 B3Configured motor and gearbox assembly reference.
Sensors & MeasurementUB40012GME5V1Pepperl+Fuchs UB400 ultrasonic sensor.
Power & CommunicationDFR713PLegacy electronic control spare; confirm manufacturer and revision.
Sensors & MeasurementPT/EL-DR-5BAR-S1-HA-TH-SS5 bar pressure-instrument reference; verify materials and output.
Sensors & MeasurementUDS3/200MB/4/20/G1/4E/FConfigured pressure sensor/transmitter reference.
Motion & DrivesVRDM397/50LWBBerger Lahr stepper motor reference.
Pneumatic & ProcessMPPES31410420Festo proportional pressure regulator reference.
Power & Communication6GK57980SN000EA0Siemens industrial communication accessory; verify installed function.
Sensors & MeasurementWTT280L-2P2531SICK PowerProx time-of-flight photoelectric sensor.
Pneumatic & ProcessMSQB20H2SMC compact rotary table/actuator reference.
Pneumatic & ProcessMSQB30H3SMC compact rotary table/actuator reference.
Power & CommunicationMCRSLUI0Phoenix Contact analog signal conditioner reference.
Motion & Drives6FX11422BA02Siemens drive/CNC electronic module reference.
No exact Nordwel product pages were found for this reference list. Final supply must be confirmed from the manufacturer nameplate, complete ordering code and installed-system context.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
New Products

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp